Cargando…

Electrochemical biosensor for detection of 17β-estradiol using semi-conducting polymer and horseradish peroxidase

A convenient electrochemical sensing pathway for 17β-estradiol detection was investigated. The system is based on a conducting polymer and horseradish peroxidase (HRP) modified platinum (Pt) electrode. The miniature estradiol biosensor was developed and constructed through the immobilization of HRP...

Descripción completa

Detalles Bibliográficos
Autores principales: Spychalska, Kamila, Zając, Dorota, Cabaj, Joanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9050037/
https://www.ncbi.nlm.nih.gov/pubmed/35496550
http://dx.doi.org/10.1039/c9ra09902f
_version_ 1784696277387182080
author Spychalska, Kamila
Zając, Dorota
Cabaj, Joanna
author_facet Spychalska, Kamila
Zając, Dorota
Cabaj, Joanna
author_sort Spychalska, Kamila
collection PubMed
description A convenient electrochemical sensing pathway for 17β-estradiol detection was investigated. The system is based on a conducting polymer and horseradish peroxidase (HRP) modified platinum (Pt) electrode. The miniature estradiol biosensor was developed and constructed through the immobilization of HRP in an electroactive surface of the electrode covered with electroconducting polymer – poly(4,7-bis(5-(3,4-ethylenedioxythiophene)thiophen-2-yl)benzothiadiazole). The detection strategy is based on the fact that 17β-estradiol (E2) and pyrocatechol (H(2)Q) are co-substrates for the HRP enzyme. HRP, which does not react with E2, in the presence of H(2)O(2) catalyses the oxidation of H(2)Q to o-benzoquinone (Q). With the optimized conditions, such constructed biosensing system demonstrated a convenient level of sensitivity, selectivity in a broad linear range – 0.1 to 200 μM with a detection limit of 105 nM. Furthermore, the method was successfully applied for hormone detection in the presence of potential interfering compounds (ascorbic acid, estriol, estrone, uric acid and cholesterol).
format Online
Article
Text
id pubmed-9050037
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90500372022-04-29 Electrochemical biosensor for detection of 17β-estradiol using semi-conducting polymer and horseradish peroxidase Spychalska, Kamila Zając, Dorota Cabaj, Joanna RSC Adv Chemistry A convenient electrochemical sensing pathway for 17β-estradiol detection was investigated. The system is based on a conducting polymer and horseradish peroxidase (HRP) modified platinum (Pt) electrode. The miniature estradiol biosensor was developed and constructed through the immobilization of HRP in an electroactive surface of the electrode covered with electroconducting polymer – poly(4,7-bis(5-(3,4-ethylenedioxythiophene)thiophen-2-yl)benzothiadiazole). The detection strategy is based on the fact that 17β-estradiol (E2) and pyrocatechol (H(2)Q) are co-substrates for the HRP enzyme. HRP, which does not react with E2, in the presence of H(2)O(2) catalyses the oxidation of H(2)Q to o-benzoquinone (Q). With the optimized conditions, such constructed biosensing system demonstrated a convenient level of sensitivity, selectivity in a broad linear range – 0.1 to 200 μM with a detection limit of 105 nM. Furthermore, the method was successfully applied for hormone detection in the presence of potential interfering compounds (ascorbic acid, estriol, estrone, uric acid and cholesterol). The Royal Society of Chemistry 2020-03-03 /pmc/articles/PMC9050037/ /pubmed/35496550 http://dx.doi.org/10.1039/c9ra09902f Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Spychalska, Kamila
Zając, Dorota
Cabaj, Joanna
Electrochemical biosensor for detection of 17β-estradiol using semi-conducting polymer and horseradish peroxidase
title Electrochemical biosensor for detection of 17β-estradiol using semi-conducting polymer and horseradish peroxidase
title_full Electrochemical biosensor for detection of 17β-estradiol using semi-conducting polymer and horseradish peroxidase
title_fullStr Electrochemical biosensor for detection of 17β-estradiol using semi-conducting polymer and horseradish peroxidase
title_full_unstemmed Electrochemical biosensor for detection of 17β-estradiol using semi-conducting polymer and horseradish peroxidase
title_short Electrochemical biosensor for detection of 17β-estradiol using semi-conducting polymer and horseradish peroxidase
title_sort electrochemical biosensor for detection of 17β-estradiol using semi-conducting polymer and horseradish peroxidase
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9050037/
https://www.ncbi.nlm.nih.gov/pubmed/35496550
http://dx.doi.org/10.1039/c9ra09902f
work_keys_str_mv AT spychalskakamila electrochemicalbiosensorfordetectionof17bestradiolusingsemiconductingpolymerandhorseradishperoxidase
AT zajacdorota electrochemicalbiosensorfordetectionof17bestradiolusingsemiconductingpolymerandhorseradishperoxidase
AT cabajjoanna electrochemicalbiosensorfordetectionof17bestradiolusingsemiconductingpolymerandhorseradishperoxidase