Cargando…
The Volume of T2 Low-Signal Band and the Width of the Widest Blood Vessel in Placenta Measured by MRI in Pregnant Women with Different Types of Placental Implantation and Its Differential Value
OBJECTIVE: To explore the value of magnetic resonance imaging (MRI) in measuring the volume of T2 low-signal band and the width change of the widest blood vessel in placenta in pregnant women with different types of placenta implantation (PI). METHODS: From November 2020 to August 2021, 116 patients...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9050272/ https://www.ncbi.nlm.nih.gov/pubmed/35495887 http://dx.doi.org/10.1155/2022/7546201 |
_version_ | 1784696324580442112 |
---|---|
author | Duan, Jun Su, Jianqiang Zhang, Yun Ma, Like Zhao, Liang |
author_facet | Duan, Jun Su, Jianqiang Zhang, Yun Ma, Like Zhao, Liang |
author_sort | Duan, Jun |
collection | PubMed |
description | OBJECTIVE: To explore the value of magnetic resonance imaging (MRI) in measuring the volume of T2 low-signal band and the width change of the widest blood vessel in placenta in pregnant women with different types of placenta implantation (PI). METHODS: From November 2020 to August 2021, 116 patients in our hospital who underwent placental MRI because of ultrasound or clinical suspicion of PI were selected as the research object. According to the “gold standard” (clinical or surgical pathological results), 79 cases with PI were diagnosed as PI group, and 37 cases without PI were no PI group. The clinical features, MRI signs, T2 hyposignal zone volume, and the width of the widest blood vessel in placenta were compared between the two groups and different types of PI patients. Logistic regression was used to analyze the influencing factors of PI and PI classification, and the receiver-operating characteristic (ROC) was used to analyze the value of T2 low-signal zone volume and the widest blood vessel width in the placenta for different types of PI. RESULTS: The history of cesarean section, uneven placental signal, the proportion of T2 low-signal band shadow, the volume of T2 low-signal band, and the width of the widest blood vessel in placenta in PI group were higher than those in non-PI group (p < 0.05); the history of cesarean section, uneven placental signal, T2 hypointense band shadow, the volume of T2 hypointense band, and the increase of the width of the widest blood vessel in placenta are independent risk factors for PI (p < 0.05); with the increase of implantation depth, the proportion of T2 hypointense band shadow, the volume of T2 hypointense band, and the width of the widest blood vessel in placenta gradually increased (p < 0.05); T2 hypointense band shadow, T2 hypointense band volume, and the widest blood vessel width in placenta are all influencing factors of PI classification (p < 0.05); ROC showed that the volume of T2 low-signal band and the width of the widest blood vessel in placenta, the AUC of combined identification of adhesive PI, implanted PI, implanted PI, and penetrating PI were 0.846 and 0.899, respectively, which was higher than that of single identification (p < 0.05). CONCLUSION: MRI measurement of T2 hyposignal zone volume and the widest blood vessel width in placenta can be used for PI diagnosis and classification differentiation and provide reliable basis for clinical prenatal preparation and treatment planning. |
format | Online Article Text |
id | pubmed-9050272 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-90502722022-04-29 The Volume of T2 Low-Signal Band and the Width of the Widest Blood Vessel in Placenta Measured by MRI in Pregnant Women with Different Types of Placental Implantation and Its Differential Value Duan, Jun Su, Jianqiang Zhang, Yun Ma, Like Zhao, Liang Comput Math Methods Med Research Article OBJECTIVE: To explore the value of magnetic resonance imaging (MRI) in measuring the volume of T2 low-signal band and the width change of the widest blood vessel in placenta in pregnant women with different types of placenta implantation (PI). METHODS: From November 2020 to August 2021, 116 patients in our hospital who underwent placental MRI because of ultrasound or clinical suspicion of PI were selected as the research object. According to the “gold standard” (clinical or surgical pathological results), 79 cases with PI were diagnosed as PI group, and 37 cases without PI were no PI group. The clinical features, MRI signs, T2 hyposignal zone volume, and the width of the widest blood vessel in placenta were compared between the two groups and different types of PI patients. Logistic regression was used to analyze the influencing factors of PI and PI classification, and the receiver-operating characteristic (ROC) was used to analyze the value of T2 low-signal zone volume and the widest blood vessel width in the placenta for different types of PI. RESULTS: The history of cesarean section, uneven placental signal, the proportion of T2 low-signal band shadow, the volume of T2 low-signal band, and the width of the widest blood vessel in placenta in PI group were higher than those in non-PI group (p < 0.05); the history of cesarean section, uneven placental signal, T2 hypointense band shadow, the volume of T2 hypointense band, and the increase of the width of the widest blood vessel in placenta are independent risk factors for PI (p < 0.05); with the increase of implantation depth, the proportion of T2 hypointense band shadow, the volume of T2 hypointense band, and the width of the widest blood vessel in placenta gradually increased (p < 0.05); T2 hypointense band shadow, T2 hypointense band volume, and the widest blood vessel width in placenta are all influencing factors of PI classification (p < 0.05); ROC showed that the volume of T2 low-signal band and the width of the widest blood vessel in placenta, the AUC of combined identification of adhesive PI, implanted PI, implanted PI, and penetrating PI were 0.846 and 0.899, respectively, which was higher than that of single identification (p < 0.05). CONCLUSION: MRI measurement of T2 hyposignal zone volume and the widest blood vessel width in placenta can be used for PI diagnosis and classification differentiation and provide reliable basis for clinical prenatal preparation and treatment planning. Hindawi 2022-04-21 /pmc/articles/PMC9050272/ /pubmed/35495887 http://dx.doi.org/10.1155/2022/7546201 Text en Copyright © 2022 Jun Duan et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Duan, Jun Su, Jianqiang Zhang, Yun Ma, Like Zhao, Liang The Volume of T2 Low-Signal Band and the Width of the Widest Blood Vessel in Placenta Measured by MRI in Pregnant Women with Different Types of Placental Implantation and Its Differential Value |
title | The Volume of T2 Low-Signal Band and the Width of the Widest Blood Vessel in Placenta Measured by MRI in Pregnant Women with Different Types of Placental Implantation and Its Differential Value |
title_full | The Volume of T2 Low-Signal Band and the Width of the Widest Blood Vessel in Placenta Measured by MRI in Pregnant Women with Different Types of Placental Implantation and Its Differential Value |
title_fullStr | The Volume of T2 Low-Signal Band and the Width of the Widest Blood Vessel in Placenta Measured by MRI in Pregnant Women with Different Types of Placental Implantation and Its Differential Value |
title_full_unstemmed | The Volume of T2 Low-Signal Band and the Width of the Widest Blood Vessel in Placenta Measured by MRI in Pregnant Women with Different Types of Placental Implantation and Its Differential Value |
title_short | The Volume of T2 Low-Signal Band and the Width of the Widest Blood Vessel in Placenta Measured by MRI in Pregnant Women with Different Types of Placental Implantation and Its Differential Value |
title_sort | volume of t2 low-signal band and the width of the widest blood vessel in placenta measured by mri in pregnant women with different types of placental implantation and its differential value |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9050272/ https://www.ncbi.nlm.nih.gov/pubmed/35495887 http://dx.doi.org/10.1155/2022/7546201 |
work_keys_str_mv | AT duanjun thevolumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue AT sujianqiang thevolumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue AT zhangyun thevolumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue AT malike thevolumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue AT zhaoliang thevolumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue AT duanjun volumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue AT sujianqiang volumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue AT zhangyun volumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue AT malike volumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue AT zhaoliang volumeoft2lowsignalbandandthewidthofthewidestbloodvesselinplacentameasuredbymriinpregnantwomenwithdifferenttypesofplacentalimplantationanditsdifferentialvalue |