Cargando…
Efficient extraction of aromatic amines in the air by the needle trap device packed with the zirconium based metal–organic framework sorbent
In this study, development of a needle trap device (NTD) packed with UiO-66 adsorbent was used for the sampling of the aromatic amine compounds (including aniline, N,N-dimethylaniline and o-toluidine) followed by gas chromatography (GC) with flame-ionization detector (FID) analysis. The UiO-66 sorbe...
Autores principales: | Alinaghi Langari, Ali Akbar, Firoozichahak, Ali, Alizadeh, Saber, Nematollahi, Davood, Farhadian, Maryam |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9051570/ https://www.ncbi.nlm.nih.gov/pubmed/35492999 http://dx.doi.org/10.1039/d0ra00687d |
Ejemplares similares
-
Nano-hydroxyapatite/polyaniline composite as an efficient sorbent for sensitive determination of the polycyclic aromatic hydrocarbons in air by a needle trap device
por: Alinaghi Langari, Ali Akbar, et al.
Publicado: (2020) -
Determination of halogenated hydrocarbons in urine samples using a needle trap device packed with Ni/Zn–BTC bi-MMOF via the dynamic headspace method
por: Rahimpoor, Razzagh, et al.
Publicado: (2021) -
Urinary bio-monitoring of amphetamine derivatives by needle trap device packed with the zirconium-based metal–organic framework
por: Rahimpoor, Razzagh, et al.
Publicado: (2022) -
Urinary bio-monitoring of aromatic amine derivatives by new needle trap device packed with the multi-component adsorbent
por: Rahimpoor, Razzagh, et al.
Publicado: (2023) -
Application of a needle trap device packed with a MIP@MOF nano-composite for efficient sampling and determination of airborne diazinon pesticide
por: Rahimpoor, Razzagh, et al.
Publicado: (2022)