Cargando…
Positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: A randomized controlled trial
BACKGROUND: Post-extubation-atelectasis (PEA) is a common problem after the removal of an endotracheal tube in neonates which increases the rate of extubation failure. Different techniques have been introduced for the prevention of PEA. One technique is the removal of the endotracheal tube by negati...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9052286/ https://www.ncbi.nlm.nih.gov/pubmed/35495371 http://dx.doi.org/10.1016/j.amsu.2022.103573 |
_version_ | 1784696753698635776 |
---|---|
author | Farhadi, Roya Nakhshab, Maryam Hojjati, Atefeh Khademloo, Mohammad |
author_facet | Farhadi, Roya Nakhshab, Maryam Hojjati, Atefeh Khademloo, Mohammad |
author_sort | Farhadi, Roya |
collection | PubMed |
description | BACKGROUND: Post-extubation-atelectasis (PEA) is a common problem after the removal of an endotracheal tube in neonates which increases the rate of extubation failure. Different techniques have been introduced for the prevention of PEA. One technique is the removal of the endotracheal tube by negative or positive gradients of pressure. No RCT has yet been done to compare the use of these two methods in neonates. So this study aimed to compare the role of positive and negative pressure during extubation of neonates on the prevention of PEA. MATERIALS AND METHODS: We enrolled 100 newborns in this RCT that required at least 24 h of mechanical ventilation. The endotracheal tube in one group was removed by a T-Piece resuscitator at a PEEP level of 5 CmH2o while in another group extubation was done applying suction pressure of 100 mmHg by random selection. Prevalence of PEA in CXRs after extubation was compared between the two groups. RESULTS: The prevalence of PEA in the extubation of the positive pressure group (24%) was significantly lower than that of the negative pressure group (46%) (p = 0.024). Extubation failure was found to be lower in the positive pressure group (6% versus 20% P = 0.037). No significant difference was observed between the two groups in the prevalence of apnea, pneumothorax, and death at 3 days after extubation. CONCLUSION: The use of positive pressure during removal of the endotracheal tube in newborn infants reduced the rate of PEA compared with the negative pressure so extubation by a positive pressure is recommended in neonates. |
format | Online Article Text |
id | pubmed-9052286 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-90522862022-04-30 Positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: A randomized controlled trial Farhadi, Roya Nakhshab, Maryam Hojjati, Atefeh Khademloo, Mohammad Ann Med Surg (Lond) Experimental Research BACKGROUND: Post-extubation-atelectasis (PEA) is a common problem after the removal of an endotracheal tube in neonates which increases the rate of extubation failure. Different techniques have been introduced for the prevention of PEA. One technique is the removal of the endotracheal tube by negative or positive gradients of pressure. No RCT has yet been done to compare the use of these two methods in neonates. So this study aimed to compare the role of positive and negative pressure during extubation of neonates on the prevention of PEA. MATERIALS AND METHODS: We enrolled 100 newborns in this RCT that required at least 24 h of mechanical ventilation. The endotracheal tube in one group was removed by a T-Piece resuscitator at a PEEP level of 5 CmH2o while in another group extubation was done applying suction pressure of 100 mmHg by random selection. Prevalence of PEA in CXRs after extubation was compared between the two groups. RESULTS: The prevalence of PEA in the extubation of the positive pressure group (24%) was significantly lower than that of the negative pressure group (46%) (p = 0.024). Extubation failure was found to be lower in the positive pressure group (6% versus 20% P = 0.037). No significant difference was observed between the two groups in the prevalence of apnea, pneumothorax, and death at 3 days after extubation. CONCLUSION: The use of positive pressure during removal of the endotracheal tube in newborn infants reduced the rate of PEA compared with the negative pressure so extubation by a positive pressure is recommended in neonates. Elsevier 2022-04-04 /pmc/articles/PMC9052286/ /pubmed/35495371 http://dx.doi.org/10.1016/j.amsu.2022.103573 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Experimental Research Farhadi, Roya Nakhshab, Maryam Hojjati, Atefeh Khademloo, Mohammad Positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: A randomized controlled trial |
title | Positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: A randomized controlled trial |
title_full | Positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: A randomized controlled trial |
title_fullStr | Positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: A randomized controlled trial |
title_full_unstemmed | Positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: A randomized controlled trial |
title_short | Positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: A randomized controlled trial |
title_sort | positive versus negative pressure during removal of endotracheal-tube on prevention of post-extubation atelectasis in ventilated neonates: a randomized controlled trial |
topic | Experimental Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9052286/ https://www.ncbi.nlm.nih.gov/pubmed/35495371 http://dx.doi.org/10.1016/j.amsu.2022.103573 |
work_keys_str_mv | AT farhadiroya positiveversusnegativepressureduringremovalofendotrachealtubeonpreventionofpostextubationatelectasisinventilatedneonatesarandomizedcontrolledtrial AT nakhshabmaryam positiveversusnegativepressureduringremovalofendotrachealtubeonpreventionofpostextubationatelectasisinventilatedneonatesarandomizedcontrolledtrial AT hojjatiatefeh positiveversusnegativepressureduringremovalofendotrachealtubeonpreventionofpostextubationatelectasisinventilatedneonatesarandomizedcontrolledtrial AT khademloomohammad positiveversusnegativepressureduringremovalofendotrachealtubeonpreventionofpostextubationatelectasisinventilatedneonatesarandomizedcontrolledtrial |