Cargando…
Autopsy Validation of the Diagnostic Accuracy of (123)I-Metaiodobenzylguanidine Myocardial Scintigraphy for Lewy Body Disease
BACKGROUND AND OBJECTIVES: (123)I-meta-iodobenzyl-guanidine ((123)I-MIBG) myocardial scintigraphy is used as a diagnostic imaging test to differentiate Lewy body diseases (LBDs), including Parkinson disease and dementia with Lewy bodies, from other similar diseases. However, this imaging test lacks...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9052572/ https://www.ncbi.nlm.nih.gov/pubmed/35256483 http://dx.doi.org/10.1212/WNL.0000000000200110 |
_version_ | 1784696811537039360 |
---|---|
author | Matsubara, Tomoyasu Kameyama, Masashi Tanaka, Noriko Sengoku, Renpei Orita, Makoto Furuta, Ko Iwata, Atsushi Arai, Tomio Maruyama, Hirofumi Saito, Yuko Murayama, Shigeo |
author_facet | Matsubara, Tomoyasu Kameyama, Masashi Tanaka, Noriko Sengoku, Renpei Orita, Makoto Furuta, Ko Iwata, Atsushi Arai, Tomio Maruyama, Hirofumi Saito, Yuko Murayama, Shigeo |
author_sort | Matsubara, Tomoyasu |
collection | PubMed |
description | BACKGROUND AND OBJECTIVES: (123)I-meta-iodobenzyl-guanidine ((123)I-MIBG) myocardial scintigraphy is used as a diagnostic imaging test to differentiate Lewy body diseases (LBDs), including Parkinson disease and dementia with Lewy bodies, from other similar diseases. However, this imaging test lacks validation of its diagnostic accuracy against the gold standard. Our aim was to validate the diagnostic accuracy of (123)I-MIBG myocardial scintigraphy for LBD against autopsy, the gold standard. METHODS: This retrospective, cross-sectional study included consecutive autopsy patients from the Brain Bank for Aging Research who had undergone (123)I-MIBG myocardial scintigraphy. We compared the (123)I-MIBG myocardial scintigraphy findings with autopsy findings. Furthermore, the proportion of residual tyrosine hydroxylase (TH)–immunoreactive sympathetic fibers in the anterior wall of the left ventricle was investigated to assess the condition of the cardiac sympathetic nerves assumed to cause reduced (123)I-MIBG uptake in LBDs. RESULTS: We analyzed the data of 56 patients (30 with pathologically confirmed LBDs and 26 without LBD pathology). Compared with the neuropathologic diagnosis, the early heart-to-mediastinum (H/M) ratio had a sensitivity and specificity of 70.0% (95% CI 50.6%–85.3%) and 96.2% (95% CI 80.4%–99.9%), respectively. The delayed H/M ratio had a sensitivity and specificity of 80.0% (95% CI 61.4%–92.3%) and 92.3% (95% CI 74.9%–99.1%), respectively. The washout rate had a sensitivity and specificity of 80.0% (95% CI 61.4%–92.3%) and 84.6% (95% CI 65.1%–95.6%), respectively. The proportion of residual TH-immunoreactive cardiac sympathetic fibers strongly correlated with the amount of cardiac (123)I-MIBG uptake when assessed with early and delayed H/M ratio values (correlation coefficient 0.75 and 0.81, respectively; p < 0.001). DISCUSSION: This clinicopathologic validation study revealed that (123)I-MIBG myocardial scintigraphy could robustly differentiate LBDs from similar diseases. Abnormal (123)I-MIBG myocardial scintigraphy findings strongly support the presence of LBD and cardiac sympathetic denervation. However, LBD pathology should not necessarily be excluded by normal myocardial scintigraphy results, especially when other biomarkers suggest the presence of comorbid Alzheimer disease pathology. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that (123)I-MIBG myocardial scintigraphy accurately identifies patients with LBD. |
format | Online Article Text |
id | pubmed-9052572 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-90525722022-05-02 Autopsy Validation of the Diagnostic Accuracy of (123)I-Metaiodobenzylguanidine Myocardial Scintigraphy for Lewy Body Disease Matsubara, Tomoyasu Kameyama, Masashi Tanaka, Noriko Sengoku, Renpei Orita, Makoto Furuta, Ko Iwata, Atsushi Arai, Tomio Maruyama, Hirofumi Saito, Yuko Murayama, Shigeo Neurology Research Article BACKGROUND AND OBJECTIVES: (123)I-meta-iodobenzyl-guanidine ((123)I-MIBG) myocardial scintigraphy is used as a diagnostic imaging test to differentiate Lewy body diseases (LBDs), including Parkinson disease and dementia with Lewy bodies, from other similar diseases. However, this imaging test lacks validation of its diagnostic accuracy against the gold standard. Our aim was to validate the diagnostic accuracy of (123)I-MIBG myocardial scintigraphy for LBD against autopsy, the gold standard. METHODS: This retrospective, cross-sectional study included consecutive autopsy patients from the Brain Bank for Aging Research who had undergone (123)I-MIBG myocardial scintigraphy. We compared the (123)I-MIBG myocardial scintigraphy findings with autopsy findings. Furthermore, the proportion of residual tyrosine hydroxylase (TH)–immunoreactive sympathetic fibers in the anterior wall of the left ventricle was investigated to assess the condition of the cardiac sympathetic nerves assumed to cause reduced (123)I-MIBG uptake in LBDs. RESULTS: We analyzed the data of 56 patients (30 with pathologically confirmed LBDs and 26 without LBD pathology). Compared with the neuropathologic diagnosis, the early heart-to-mediastinum (H/M) ratio had a sensitivity and specificity of 70.0% (95% CI 50.6%–85.3%) and 96.2% (95% CI 80.4%–99.9%), respectively. The delayed H/M ratio had a sensitivity and specificity of 80.0% (95% CI 61.4%–92.3%) and 92.3% (95% CI 74.9%–99.1%), respectively. The washout rate had a sensitivity and specificity of 80.0% (95% CI 61.4%–92.3%) and 84.6% (95% CI 65.1%–95.6%), respectively. The proportion of residual TH-immunoreactive cardiac sympathetic fibers strongly correlated with the amount of cardiac (123)I-MIBG uptake when assessed with early and delayed H/M ratio values (correlation coefficient 0.75 and 0.81, respectively; p < 0.001). DISCUSSION: This clinicopathologic validation study revealed that (123)I-MIBG myocardial scintigraphy could robustly differentiate LBDs from similar diseases. Abnormal (123)I-MIBG myocardial scintigraphy findings strongly support the presence of LBD and cardiac sympathetic denervation. However, LBD pathology should not necessarily be excluded by normal myocardial scintigraphy results, especially when other biomarkers suggest the presence of comorbid Alzheimer disease pathology. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that (123)I-MIBG myocardial scintigraphy accurately identifies patients with LBD. Lippincott Williams & Wilkins 2022-04-19 /pmc/articles/PMC9052572/ /pubmed/35256483 http://dx.doi.org/10.1212/WNL.0000000000200110 Text en Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0 (CC BY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits downloading and sharing the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Research Article Matsubara, Tomoyasu Kameyama, Masashi Tanaka, Noriko Sengoku, Renpei Orita, Makoto Furuta, Ko Iwata, Atsushi Arai, Tomio Maruyama, Hirofumi Saito, Yuko Murayama, Shigeo Autopsy Validation of the Diagnostic Accuracy of (123)I-Metaiodobenzylguanidine Myocardial Scintigraphy for Lewy Body Disease |
title | Autopsy Validation of the Diagnostic Accuracy of (123)I-Metaiodobenzylguanidine Myocardial Scintigraphy for Lewy Body Disease |
title_full | Autopsy Validation of the Diagnostic Accuracy of (123)I-Metaiodobenzylguanidine Myocardial Scintigraphy for Lewy Body Disease |
title_fullStr | Autopsy Validation of the Diagnostic Accuracy of (123)I-Metaiodobenzylguanidine Myocardial Scintigraphy for Lewy Body Disease |
title_full_unstemmed | Autopsy Validation of the Diagnostic Accuracy of (123)I-Metaiodobenzylguanidine Myocardial Scintigraphy for Lewy Body Disease |
title_short | Autopsy Validation of the Diagnostic Accuracy of (123)I-Metaiodobenzylguanidine Myocardial Scintigraphy for Lewy Body Disease |
title_sort | autopsy validation of the diagnostic accuracy of (123)i-metaiodobenzylguanidine myocardial scintigraphy for lewy body disease |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9052572/ https://www.ncbi.nlm.nih.gov/pubmed/35256483 http://dx.doi.org/10.1212/WNL.0000000000200110 |
work_keys_str_mv | AT matsubaratomoyasu autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT kameyamamasashi autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT tanakanoriko autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT sengokurenpei autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT oritamakoto autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT furutako autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT iwataatsushi autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT araitomio autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT maruyamahirofumi autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT saitoyuko autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease AT murayamashigeo autopsyvalidationofthediagnosticaccuracyof123imetaiodobenzylguanidinemyocardialscintigraphyforlewybodydisease |