Cargando…

A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples

Due to the toxicity of lead(ii) to all living organisms as it destroys the central nervous system leading to circulatory system and brain disorders, the development of effective and selective lead(ii) ionophores for its detection is very important. In this work, 1,3-bis[2-(N-morpholino)acetamidophen...

Descripción completa

Detalles Bibliográficos
Autores principales: Zayed, M. A., Mahmoud, Walaa H., Abbas, Ashraf A., Ali, Aya E., Mohamed, Gehad G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9053576/
https://www.ncbi.nlm.nih.gov/pubmed/35515636
http://dx.doi.org/10.1039/d0ra01435d
_version_ 1784697010832539648
author Zayed, M. A.
Mahmoud, Walaa H.
Abbas, Ashraf A.
Ali, Aya E.
Mohamed, Gehad G.
author_facet Zayed, M. A.
Mahmoud, Walaa H.
Abbas, Ashraf A.
Ali, Aya E.
Mohamed, Gehad G.
author_sort Zayed, M. A.
collection PubMed
description Due to the toxicity of lead(ii) to all living organisms as it destroys the central nervous system leading to circulatory system and brain disorders, the development of effective and selective lead(ii) ionophores for its detection is very important. In this work, 1,3-bis[2-(N-morpholino)acetamidophenoxy]propane (BMAPP), belonging to acyclic diamides, was applied as a highly selective lead(ii) ionophore in a carbon paste ion selective electrode for the accurate and precise determination of Pb(ii) ions even in the presence of other interfering ions. Factors affecting the electrode's response behavior were studied and optimized. Scanning electron microscopy (SEM), energy dispersive X-ray (EDX) and FT-IR spectroscopy were used for studying the morphology and response mechanism of the prepared sensor. The lipophilicity of the used ionophore, which contributes to the mechanical stability of the sensor, was studied using the contact angle measurement technique. The selectivity coefficients obtained by the separate solution method (SSM) and fixed interference method (FIM) confirmed the selectivity of the proposed sensor for Pb(ii) ions. The proposed sensor exhibited a Nernstian slope of 29.96 ± 0.34 mV per decade over a wide linear range of 5 × 10(−8) to 1 × 10(−1) mol L(−1) and detection limit of 3 × 10(−8) mol L(−1) for 2 months with a fast response time (<10 s) and working pH range (2.5–5.5). To further ensure the practical applicability of the sensor, it was successfully applied for the lead(ii) ion determination in different water samples and the obtained data showed an agreement with those obtained by atomic absorption spectroscopy. In addition, it was successfully applied for the potentiometric titration of Pb(ii) against K(2)CrO(4) and Na(2)SO(4).
format Online
Article
Text
id pubmed-9053576
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90535762022-05-04 A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples Zayed, M. A. Mahmoud, Walaa H. Abbas, Ashraf A. Ali, Aya E. Mohamed, Gehad G. RSC Adv Chemistry Due to the toxicity of lead(ii) to all living organisms as it destroys the central nervous system leading to circulatory system and brain disorders, the development of effective and selective lead(ii) ionophores for its detection is very important. In this work, 1,3-bis[2-(N-morpholino)acetamidophenoxy]propane (BMAPP), belonging to acyclic diamides, was applied as a highly selective lead(ii) ionophore in a carbon paste ion selective electrode for the accurate and precise determination of Pb(ii) ions even in the presence of other interfering ions. Factors affecting the electrode's response behavior were studied and optimized. Scanning electron microscopy (SEM), energy dispersive X-ray (EDX) and FT-IR spectroscopy were used for studying the morphology and response mechanism of the prepared sensor. The lipophilicity of the used ionophore, which contributes to the mechanical stability of the sensor, was studied using the contact angle measurement technique. The selectivity coefficients obtained by the separate solution method (SSM) and fixed interference method (FIM) confirmed the selectivity of the proposed sensor for Pb(ii) ions. The proposed sensor exhibited a Nernstian slope of 29.96 ± 0.34 mV per decade over a wide linear range of 5 × 10(−8) to 1 × 10(−1) mol L(−1) and detection limit of 3 × 10(−8) mol L(−1) for 2 months with a fast response time (<10 s) and working pH range (2.5–5.5). To further ensure the practical applicability of the sensor, it was successfully applied for the lead(ii) ion determination in different water samples and the obtained data showed an agreement with those obtained by atomic absorption spectroscopy. In addition, it was successfully applied for the potentiometric titration of Pb(ii) against K(2)CrO(4) and Na(2)SO(4). The Royal Society of Chemistry 2020-05-06 /pmc/articles/PMC9053576/ /pubmed/35515636 http://dx.doi.org/10.1039/d0ra01435d Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Zayed, M. A.
Mahmoud, Walaa H.
Abbas, Ashraf A.
Ali, Aya E.
Mohamed, Gehad G.
A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples
title A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples
title_full A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples
title_fullStr A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples
title_full_unstemmed A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples
title_short A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples
title_sort highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9053576/
https://www.ncbi.nlm.nih.gov/pubmed/35515636
http://dx.doi.org/10.1039/d0ra01435d
work_keys_str_mv AT zayedma ahighlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples
AT mahmoudwalaah ahighlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples
AT abbasashrafa ahighlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples
AT aliayae ahighlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples
AT mohamedgehadg ahighlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples
AT zayedma highlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples
AT mahmoudwalaah highlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples
AT abbasashrafa highlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples
AT aliayae highlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples
AT mohamedgehadg highlysensitiveselectiveandrenewablecarbonpasteelectrodebasedonauniqueacyclicdiamideionophoreforthepotentiometricdeterminationofleadionsinpollutedwatersamples