Cargando…

Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study

BACKGROUND AND AIMS: The risk of contracting infection while intubating a coronavirus disease 2019 (COVID-19)-positive patient can be reduced by the use of personal protective equipment (PPE), video laryngoscope (VL) and aerosol-preventing intubation box. We compared two VLs (C-MAC and King Vision l...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumar, Balbir, Ratre, Brajesh K., Garg, Rakesh, Meena, Jitendra K., Singh, Ram, Bhatnagar, Sushma
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9053892/
https://www.ncbi.nlm.nih.gov/pubmed/35497695
http://dx.doi.org/10.4103/ija.ija_832_21
_version_ 1784697068862832640
author Kumar, Balbir
Ratre, Brajesh K.
Garg, Rakesh
Meena, Jitendra K.
Singh, Ram
Bhatnagar, Sushma
author_facet Kumar, Balbir
Ratre, Brajesh K.
Garg, Rakesh
Meena, Jitendra K.
Singh, Ram
Bhatnagar, Sushma
author_sort Kumar, Balbir
collection PubMed
description BACKGROUND AND AIMS: The risk of contracting infection while intubating a coronavirus disease 2019 (COVID-19)-positive patient can be reduced by the use of personal protective equipment (PPE), video laryngoscope (VL) and aerosol-preventing intubation box. We compared two VLs (C-MAC and King Vision laryngoscope [KVL]) for ease of intubation and time taken to intubate the manikin using an intubation box. METHODS: This randomised study involved healthcare workers having experience in using both C-MAC and KVL. After explaining the study and five practice sessions, a total of 63 volunteers were included; 61 participants gave consent and were enroled. The participants were allowed to intubate initially with one VL as per random sequence. Each participant performed three tracheal intubations with each device (C-MAC VL and KVL) on a manikin using an aerosol-prevention box over the head end at the time of intubation. RESULTS: Time taken, percentage of glottic opening (POGO) score and the number of attempts taken for successful intubation with C-MAC and KVL were comparable in any of the three attempts (P > 0.05). The participants reported more difficulty in using KVL compared to C-MAC, and insertion of laryngoscope blade into the mouth of manikin for intubation was easy in group C-MAC compared to KVL in all three intubations (P < 0.01). CONCLUSION: C-MAC and KVL take comparable time for successful intubation under COVID-19 simulation conditions. But C-MAC is more user-friendly.
format Online
Article
Text
id pubmed-9053892
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-90538922022-04-30 Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study Kumar, Balbir Ratre, Brajesh K. Garg, Rakesh Meena, Jitendra K. Singh, Ram Bhatnagar, Sushma Indian J Anaesth Original Article BACKGROUND AND AIMS: The risk of contracting infection while intubating a coronavirus disease 2019 (COVID-19)-positive patient can be reduced by the use of personal protective equipment (PPE), video laryngoscope (VL) and aerosol-preventing intubation box. We compared two VLs (C-MAC and King Vision laryngoscope [KVL]) for ease of intubation and time taken to intubate the manikin using an intubation box. METHODS: This randomised study involved healthcare workers having experience in using both C-MAC and KVL. After explaining the study and five practice sessions, a total of 63 volunteers were included; 61 participants gave consent and were enroled. The participants were allowed to intubate initially with one VL as per random sequence. Each participant performed three tracheal intubations with each device (C-MAC VL and KVL) on a manikin using an aerosol-prevention box over the head end at the time of intubation. RESULTS: Time taken, percentage of glottic opening (POGO) score and the number of attempts taken for successful intubation with C-MAC and KVL were comparable in any of the three attempts (P > 0.05). The participants reported more difficulty in using KVL compared to C-MAC, and insertion of laryngoscope blade into the mouth of manikin for intubation was easy in group C-MAC compared to KVL in all three intubations (P < 0.01). CONCLUSION: C-MAC and KVL take comparable time for successful intubation under COVID-19 simulation conditions. But C-MAC is more user-friendly. Wolters Kluwer - Medknow 2022-03 2022-03-24 /pmc/articles/PMC9053892/ /pubmed/35497695 http://dx.doi.org/10.4103/ija.ija_832_21 Text en Copyright: © 2022 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kumar, Balbir
Ratre, Brajesh K.
Garg, Rakesh
Meena, Jitendra K.
Singh, Ram
Bhatnagar, Sushma
Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study
title Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study
title_full Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study
title_fullStr Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study
title_full_unstemmed Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study
title_short Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study
title_sort comparison between c-mac and king vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for covid-19 patients: a manikin-based study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9053892/
https://www.ncbi.nlm.nih.gov/pubmed/35497695
http://dx.doi.org/10.4103/ija.ija_832_21
work_keys_str_mv AT kumarbalbir comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy
AT ratrebrajeshk comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy
AT gargrakesh comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy
AT meenajitendrak comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy
AT singhram comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy
AT bhatnagarsushma comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy