Cargando…
Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study
BACKGROUND AND AIMS: The risk of contracting infection while intubating a coronavirus disease 2019 (COVID-19)-positive patient can be reduced by the use of personal protective equipment (PPE), video laryngoscope (VL) and aerosol-preventing intubation box. We compared two VLs (C-MAC and King Vision l...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9053892/ https://www.ncbi.nlm.nih.gov/pubmed/35497695 http://dx.doi.org/10.4103/ija.ija_832_21 |
_version_ | 1784697068862832640 |
---|---|
author | Kumar, Balbir Ratre, Brajesh K. Garg, Rakesh Meena, Jitendra K. Singh, Ram Bhatnagar, Sushma |
author_facet | Kumar, Balbir Ratre, Brajesh K. Garg, Rakesh Meena, Jitendra K. Singh, Ram Bhatnagar, Sushma |
author_sort | Kumar, Balbir |
collection | PubMed |
description | BACKGROUND AND AIMS: The risk of contracting infection while intubating a coronavirus disease 2019 (COVID-19)-positive patient can be reduced by the use of personal protective equipment (PPE), video laryngoscope (VL) and aerosol-preventing intubation box. We compared two VLs (C-MAC and King Vision laryngoscope [KVL]) for ease of intubation and time taken to intubate the manikin using an intubation box. METHODS: This randomised study involved healthcare workers having experience in using both C-MAC and KVL. After explaining the study and five practice sessions, a total of 63 volunteers were included; 61 participants gave consent and were enroled. The participants were allowed to intubate initially with one VL as per random sequence. Each participant performed three tracheal intubations with each device (C-MAC VL and KVL) on a manikin using an aerosol-prevention box over the head end at the time of intubation. RESULTS: Time taken, percentage of glottic opening (POGO) score and the number of attempts taken for successful intubation with C-MAC and KVL were comparable in any of the three attempts (P > 0.05). The participants reported more difficulty in using KVL compared to C-MAC, and insertion of laryngoscope blade into the mouth of manikin for intubation was easy in group C-MAC compared to KVL in all three intubations (P < 0.01). CONCLUSION: C-MAC and KVL take comparable time for successful intubation under COVID-19 simulation conditions. But C-MAC is more user-friendly. |
format | Online Article Text |
id | pubmed-9053892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-90538922022-04-30 Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study Kumar, Balbir Ratre, Brajesh K. Garg, Rakesh Meena, Jitendra K. Singh, Ram Bhatnagar, Sushma Indian J Anaesth Original Article BACKGROUND AND AIMS: The risk of contracting infection while intubating a coronavirus disease 2019 (COVID-19)-positive patient can be reduced by the use of personal protective equipment (PPE), video laryngoscope (VL) and aerosol-preventing intubation box. We compared two VLs (C-MAC and King Vision laryngoscope [KVL]) for ease of intubation and time taken to intubate the manikin using an intubation box. METHODS: This randomised study involved healthcare workers having experience in using both C-MAC and KVL. After explaining the study and five practice sessions, a total of 63 volunteers were included; 61 participants gave consent and were enroled. The participants were allowed to intubate initially with one VL as per random sequence. Each participant performed three tracheal intubations with each device (C-MAC VL and KVL) on a manikin using an aerosol-prevention box over the head end at the time of intubation. RESULTS: Time taken, percentage of glottic opening (POGO) score and the number of attempts taken for successful intubation with C-MAC and KVL were comparable in any of the three attempts (P > 0.05). The participants reported more difficulty in using KVL compared to C-MAC, and insertion of laryngoscope blade into the mouth of manikin for intubation was easy in group C-MAC compared to KVL in all three intubations (P < 0.01). CONCLUSION: C-MAC and KVL take comparable time for successful intubation under COVID-19 simulation conditions. But C-MAC is more user-friendly. Wolters Kluwer - Medknow 2022-03 2022-03-24 /pmc/articles/PMC9053892/ /pubmed/35497695 http://dx.doi.org/10.4103/ija.ija_832_21 Text en Copyright: © 2022 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Kumar, Balbir Ratre, Brajesh K. Garg, Rakesh Meena, Jitendra K. Singh, Ram Bhatnagar, Sushma Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study |
title | Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study |
title_full | Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study |
title_fullStr | Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study |
title_full_unstemmed | Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study |
title_short | Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients: A manikin-based study |
title_sort | comparison between c-mac and king vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for covid-19 patients: a manikin-based study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9053892/ https://www.ncbi.nlm.nih.gov/pubmed/35497695 http://dx.doi.org/10.4103/ija.ija_832_21 |
work_keys_str_mv | AT kumarbalbir comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy AT ratrebrajeshk comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy AT gargrakesh comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy AT meenajitendrak comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy AT singhram comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy AT bhatnagarsushma comparisonbetweencmacandkingvisionvideolaryngoscopechannelledbladefortrachealintubationinaerosolpreventionintubationboxforcovid19patientsamanikinbasedstudy |