Cargando…

A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB

Platelet-derived growth factor BB (PDGF-BB) is a potential biomarker of tumor angiogenesis. For the first time, we developed a highly sensitive aptasensor for PDGF-BB with an enhanced test line signal by using two different gold nanoparticles (AuNPs). Herein, we describe a highly sensitive biosensor...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Na, Liu, Yujie, Mukama, Omar, Han, Xiaobo, Huang, Hualin, Li, Shuai, Zhou, Peng, Lu, Xuewen, Li, Zhiyuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9053969/
https://www.ncbi.nlm.nih.gov/pubmed/35518307
http://dx.doi.org/10.1039/d0ra02662j
_version_ 1784697087758172160
author Cheng, Na
Liu, Yujie
Mukama, Omar
Han, Xiaobo
Huang, Hualin
Li, Shuai
Zhou, Peng
Lu, Xuewen
Li, Zhiyuan
author_facet Cheng, Na
Liu, Yujie
Mukama, Omar
Han, Xiaobo
Huang, Hualin
Li, Shuai
Zhou, Peng
Lu, Xuewen
Li, Zhiyuan
author_sort Cheng, Na
collection PubMed
description Platelet-derived growth factor BB (PDGF-BB) is a potential biomarker of tumor angiogenesis. For the first time, we developed a highly sensitive aptasensor for PDGF-BB with an enhanced test line signal by using two different gold nanoparticles (AuNPs). Herein, we describe a highly sensitive biosensor for PDGF-BB detection that combines biotinylated aptamer on a sample pad and poly thymine-Cy3-AuNP-monoclonal antibody complexes against PDGF-BB immobilized on conjugate pad A. Streptavidin (SA) and rabbit anti-mouse polyclonal antibody were also immobilized in the nitrocellulose membrane at the test and control zones, respectively. When the target PDGF-BB protein was added, it first bound the aptamer, and later the monoclonal antibody to form a biotinylated complex that was captured by SA, resulting in a visual red line on the test zone. In addition, to enhance the sensitivity, another monoclonal antibody against Cy3 was conjugated on AuNP B and immobilized on conjugate pad B to form a AuNPs (A&B)-antibody-(PDGF-BB-Cy3)-aptamer-biotin-SA complex on the test line when a loading buffer was subsequently added. This approach showed a linear response to PDGF-BB from 3 ng mL(−1) to 300 ng mL(−1) with a limit of detection as low as 1 ng mL(−1) obtained in 10 minutes. Our biosensor displayed results through red lines readable by the naked eye. Interestingly, our approach has been successfully applied for real sample verification, proving its applicability for cancer monitoring and diagnosis.
format Online
Article
Text
id pubmed-9053969
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90539692022-05-04 A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB Cheng, Na Liu, Yujie Mukama, Omar Han, Xiaobo Huang, Hualin Li, Shuai Zhou, Peng Lu, Xuewen Li, Zhiyuan RSC Adv Chemistry Platelet-derived growth factor BB (PDGF-BB) is a potential biomarker of tumor angiogenesis. For the first time, we developed a highly sensitive aptasensor for PDGF-BB with an enhanced test line signal by using two different gold nanoparticles (AuNPs). Herein, we describe a highly sensitive biosensor for PDGF-BB detection that combines biotinylated aptamer on a sample pad and poly thymine-Cy3-AuNP-monoclonal antibody complexes against PDGF-BB immobilized on conjugate pad A. Streptavidin (SA) and rabbit anti-mouse polyclonal antibody were also immobilized in the nitrocellulose membrane at the test and control zones, respectively. When the target PDGF-BB protein was added, it first bound the aptamer, and later the monoclonal antibody to form a biotinylated complex that was captured by SA, resulting in a visual red line on the test zone. In addition, to enhance the sensitivity, another monoclonal antibody against Cy3 was conjugated on AuNP B and immobilized on conjugate pad B to form a AuNPs (A&B)-antibody-(PDGF-BB-Cy3)-aptamer-biotin-SA complex on the test line when a loading buffer was subsequently added. This approach showed a linear response to PDGF-BB from 3 ng mL(−1) to 300 ng mL(−1) with a limit of detection as low as 1 ng mL(−1) obtained in 10 minutes. Our biosensor displayed results through red lines readable by the naked eye. Interestingly, our approach has been successfully applied for real sample verification, proving its applicability for cancer monitoring and diagnosis. The Royal Society of Chemistry 2020-05-18 /pmc/articles/PMC9053969/ /pubmed/35518307 http://dx.doi.org/10.1039/d0ra02662j Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Cheng, Na
Liu, Yujie
Mukama, Omar
Han, Xiaobo
Huang, Hualin
Li, Shuai
Zhou, Peng
Lu, Xuewen
Li, Zhiyuan
A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB
title A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB
title_full A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB
title_fullStr A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB
title_full_unstemmed A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB
title_short A signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of PDGF-BB
title_sort signal-enhanced and sensitive lateral flow aptasensor for the rapid detection of pdgf-bb
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9053969/
https://www.ncbi.nlm.nih.gov/pubmed/35518307
http://dx.doi.org/10.1039/d0ra02662j
work_keys_str_mv AT chengna asignalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT liuyujie asignalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT mukamaomar asignalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT hanxiaobo asignalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT huanghualin asignalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT lishuai asignalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT zhoupeng asignalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT luxuewen asignalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT lizhiyuan asignalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT chengna signalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT liuyujie signalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT mukamaomar signalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT hanxiaobo signalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT huanghualin signalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT lishuai signalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT zhoupeng signalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT luxuewen signalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb
AT lizhiyuan signalenhancedandsensitivelateralflowaptasensorfortherapiddetectionofpdgfbb