Cargando…

Fabrication of paper microfluidic devices using a toner laser printer

This paper describes a method to fabricate microfluidic paper-based analytical devices (μPADs) using a toner laser printer. Multiple methods have been reported for the fabrication of μPADs for point-of-care diagnostics and environmental monitoring. Despite successful demonstrations, however, existin...

Descripción completa

Detalles Bibliográficos
Autores principales: Ng, James S., Hashimoto, Michinao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9056319/
https://www.ncbi.nlm.nih.gov/pubmed/35518222
http://dx.doi.org/10.1039/d0ra04301j
_version_ 1784697610922098688
author Ng, James S.
Hashimoto, Michinao
author_facet Ng, James S.
Hashimoto, Michinao
author_sort Ng, James S.
collection PubMed
description This paper describes a method to fabricate microfluidic paper-based analytical devices (μPADs) using a toner laser printer. Multiple methods have been reported for the fabrication of μPADs for point-of-care diagnostics and environmental monitoring. Despite successful demonstrations, however, existing fabrication methods depend on particular printers, in-house instruments, and synthetic materials. In particular, recent discontinuation of the solid wax printer has made it difficult to fabricate μPADs with readily available instruments. Herein we reported the fabrication of μPADs using the most widely available type of printer: a toner laser printer. Heating of printed toner at 200 °C allowed the printed toner to reflow, and the spreading of the hydrophobic polymer through the filter paper was characterized. Using the developed μPADs, we conducted model colorimetric assays for glucose and bovine serum albumin (BSA). We found that heating of filter paper at 200 °C for 60 min caused the pyrolysis of cellulose in the paper. The pyrolysis resulted in the formation of aldehydes that could interfere with molecular assays involving redox reactions. To overcome this problem, we confirmed that the removal of the aldehyde could be readily achieved by washing the μPADs with aqueous bleach. Overall, the developed fabrication method should be compatible with most toner laser printers and will make μPADs accessible in resource-limited circumstances.
format Online
Article
Text
id pubmed-9056319
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90563192022-05-04 Fabrication of paper microfluidic devices using a toner laser printer Ng, James S. Hashimoto, Michinao RSC Adv Chemistry This paper describes a method to fabricate microfluidic paper-based analytical devices (μPADs) using a toner laser printer. Multiple methods have been reported for the fabrication of μPADs for point-of-care diagnostics and environmental monitoring. Despite successful demonstrations, however, existing fabrication methods depend on particular printers, in-house instruments, and synthetic materials. In particular, recent discontinuation of the solid wax printer has made it difficult to fabricate μPADs with readily available instruments. Herein we reported the fabrication of μPADs using the most widely available type of printer: a toner laser printer. Heating of printed toner at 200 °C allowed the printed toner to reflow, and the spreading of the hydrophobic polymer through the filter paper was characterized. Using the developed μPADs, we conducted model colorimetric assays for glucose and bovine serum albumin (BSA). We found that heating of filter paper at 200 °C for 60 min caused the pyrolysis of cellulose in the paper. The pyrolysis resulted in the formation of aldehydes that could interfere with molecular assays involving redox reactions. To overcome this problem, we confirmed that the removal of the aldehyde could be readily achieved by washing the μPADs with aqueous bleach. Overall, the developed fabrication method should be compatible with most toner laser printers and will make μPADs accessible in resource-limited circumstances. The Royal Society of Chemistry 2020-08-12 /pmc/articles/PMC9056319/ /pubmed/35518222 http://dx.doi.org/10.1039/d0ra04301j Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Ng, James S.
Hashimoto, Michinao
Fabrication of paper microfluidic devices using a toner laser printer
title Fabrication of paper microfluidic devices using a toner laser printer
title_full Fabrication of paper microfluidic devices using a toner laser printer
title_fullStr Fabrication of paper microfluidic devices using a toner laser printer
title_full_unstemmed Fabrication of paper microfluidic devices using a toner laser printer
title_short Fabrication of paper microfluidic devices using a toner laser printer
title_sort fabrication of paper microfluidic devices using a toner laser printer
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9056319/
https://www.ncbi.nlm.nih.gov/pubmed/35518222
http://dx.doi.org/10.1039/d0ra04301j
work_keys_str_mv AT ngjamess fabricationofpapermicrofluidicdevicesusingatonerlaserprinter
AT hashimotomichinao fabricationofpapermicrofluidicdevicesusingatonerlaserprinter