Cargando…

Makerspace microfabrication of a stainless steel 3D microneedle electrode array (3D MEA) on a glass substrate for simultaneous optical and electrical probing of electrogenic cells

Microfabrication and assembly of a Three-Dimensional Microneedle Electrode Array (3D MEA) based on a glass-stainless steel platform is demonstrated involving the utilization of non-traditional “Makerspace Microfabrication” techniques featuring cost-effective, rapid fabrication and an assorted biocom...

Descripción completa

Detalles Bibliográficos
Autores principales: Morales-Carvajal, Paola M., Kundu, Avra, Didier, Charles M., Hart, Cacie, Sommerhage, Frank, Rajaraman, Swaminathan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9057996/
https://www.ncbi.nlm.nih.gov/pubmed/35516576
http://dx.doi.org/10.1039/d0ra06070d
_version_ 1784698025907585024
author Morales-Carvajal, Paola M.
Kundu, Avra
Didier, Charles M.
Hart, Cacie
Sommerhage, Frank
Rajaraman, Swaminathan
author_facet Morales-Carvajal, Paola M.
Kundu, Avra
Didier, Charles M.
Hart, Cacie
Sommerhage, Frank
Rajaraman, Swaminathan
author_sort Morales-Carvajal, Paola M.
collection PubMed
description Microfabrication and assembly of a Three-Dimensional Microneedle Electrode Array (3D MEA) based on a glass-stainless steel platform is demonstrated involving the utilization of non-traditional “Makerspace Microfabrication” techniques featuring cost-effective, rapid fabrication and an assorted biocompatible material palette. The stainless steel microneedle electrode array was realized by planar laser micromachining and out-of-plane transitioning to have a 3D configuration with perpendicular transition angles. The 3D MEA chip is bonded onto a glass die with metal traces routed to the periphery of the chip for electrical interfacing. Confined precision drop casting (CPDC) of PDMS is used to define an insulation layer and realize the 3D microelectrodes. The use of glass as a substrate offers optical clarity allowing for simultaneous optical and electrical probing of electrogenic cells. Additionally, an interconnect using 3D printing and conductive ink casting has been developed which allows metal traces on the glass chip to be transitioned to the bottomside of the device for interfacing with commercial data acquisition/analysis equipment. The 3D MEAs demonstrate an average impedance/phase of ∼13.3 kΩ/−12.1° at 1 kHz respectively, and an average 4.2 μV noise. Lastly, electrophysiological activity from an immortal cardiomyocyte cell line was recorded using the 3D MEA demonstrating end to end device development.
format Online
Article
Text
id pubmed-9057996
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90579962022-05-04 Makerspace microfabrication of a stainless steel 3D microneedle electrode array (3D MEA) on a glass substrate for simultaneous optical and electrical probing of electrogenic cells Morales-Carvajal, Paola M. Kundu, Avra Didier, Charles M. Hart, Cacie Sommerhage, Frank Rajaraman, Swaminathan RSC Adv Chemistry Microfabrication and assembly of a Three-Dimensional Microneedle Electrode Array (3D MEA) based on a glass-stainless steel platform is demonstrated involving the utilization of non-traditional “Makerspace Microfabrication” techniques featuring cost-effective, rapid fabrication and an assorted biocompatible material palette. The stainless steel microneedle electrode array was realized by planar laser micromachining and out-of-plane transitioning to have a 3D configuration with perpendicular transition angles. The 3D MEA chip is bonded onto a glass die with metal traces routed to the periphery of the chip for electrical interfacing. Confined precision drop casting (CPDC) of PDMS is used to define an insulation layer and realize the 3D microelectrodes. The use of glass as a substrate offers optical clarity allowing for simultaneous optical and electrical probing of electrogenic cells. Additionally, an interconnect using 3D printing and conductive ink casting has been developed which allows metal traces on the glass chip to be transitioned to the bottomside of the device for interfacing with commercial data acquisition/analysis equipment. The 3D MEAs demonstrate an average impedance/phase of ∼13.3 kΩ/−12.1° at 1 kHz respectively, and an average 4.2 μV noise. Lastly, electrophysiological activity from an immortal cardiomyocyte cell line was recorded using the 3D MEA demonstrating end to end device development. The Royal Society of Chemistry 2020-11-18 /pmc/articles/PMC9057996/ /pubmed/35516576 http://dx.doi.org/10.1039/d0ra06070d Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Morales-Carvajal, Paola M.
Kundu, Avra
Didier, Charles M.
Hart, Cacie
Sommerhage, Frank
Rajaraman, Swaminathan
Makerspace microfabrication of a stainless steel 3D microneedle electrode array (3D MEA) on a glass substrate for simultaneous optical and electrical probing of electrogenic cells
title Makerspace microfabrication of a stainless steel 3D microneedle electrode array (3D MEA) on a glass substrate for simultaneous optical and electrical probing of electrogenic cells
title_full Makerspace microfabrication of a stainless steel 3D microneedle electrode array (3D MEA) on a glass substrate for simultaneous optical and electrical probing of electrogenic cells
title_fullStr Makerspace microfabrication of a stainless steel 3D microneedle electrode array (3D MEA) on a glass substrate for simultaneous optical and electrical probing of electrogenic cells
title_full_unstemmed Makerspace microfabrication of a stainless steel 3D microneedle electrode array (3D MEA) on a glass substrate for simultaneous optical and electrical probing of electrogenic cells
title_short Makerspace microfabrication of a stainless steel 3D microneedle electrode array (3D MEA) on a glass substrate for simultaneous optical and electrical probing of electrogenic cells
title_sort makerspace microfabrication of a stainless steel 3d microneedle electrode array (3d mea) on a glass substrate for simultaneous optical and electrical probing of electrogenic cells
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9057996/
https://www.ncbi.nlm.nih.gov/pubmed/35516576
http://dx.doi.org/10.1039/d0ra06070d
work_keys_str_mv AT moralescarvajalpaolam makerspacemicrofabricationofastainlesssteel3dmicroneedleelectrodearray3dmeaonaglasssubstrateforsimultaneousopticalandelectricalprobingofelectrogeniccells
AT kunduavra makerspacemicrofabricationofastainlesssteel3dmicroneedleelectrodearray3dmeaonaglasssubstrateforsimultaneousopticalandelectricalprobingofelectrogeniccells
AT didiercharlesm makerspacemicrofabricationofastainlesssteel3dmicroneedleelectrodearray3dmeaonaglasssubstrateforsimultaneousopticalandelectricalprobingofelectrogeniccells
AT hartcacie makerspacemicrofabricationofastainlesssteel3dmicroneedleelectrodearray3dmeaonaglasssubstrateforsimultaneousopticalandelectricalprobingofelectrogeniccells
AT sommerhagefrank makerspacemicrofabricationofastainlesssteel3dmicroneedleelectrodearray3dmeaonaglasssubstrateforsimultaneousopticalandelectricalprobingofelectrogeniccells
AT rajaramanswaminathan makerspacemicrofabricationofastainlesssteel3dmicroneedleelectrodearray3dmeaonaglasssubstrateforsimultaneousopticalandelectricalprobingofelectrogeniccells