Cargando…

A colorimetric and ratiometric fluorescent sensor for sequentially detecting Cu(2+) and arginine based on a coumarin–rhodamine B derivative and its application for bioimaging

In this work, a colorimetric and ratiometric fluorescent sensor based on a coumarin–rhodamine B hybrid for the sequential recognition of Cu(2+) and arginine (Arg) via the FRET mechanism was designed and synthesized. With the addition of Cu(2+), the solution displayed a colorimetric change from pale...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Shuai, Ding, Haichang, Wang, Yuesong, Fan, Congbin, Liu, Gang, Pu, Shouzhi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9060912/
https://www.ncbi.nlm.nih.gov/pubmed/35518477
http://dx.doi.org/10.1039/c8ra09943j
_version_ 1784698610018942976
author Wang, Shuai
Ding, Haichang
Wang, Yuesong
Fan, Congbin
Liu, Gang
Pu, Shouzhi
author_facet Wang, Shuai
Ding, Haichang
Wang, Yuesong
Fan, Congbin
Liu, Gang
Pu, Shouzhi
author_sort Wang, Shuai
collection PubMed
description In this work, a colorimetric and ratiometric fluorescent sensor based on a coumarin–rhodamine B hybrid for the sequential recognition of Cu(2+) and arginine (Arg) via the FRET mechanism was designed and synthesized. With the addition of Cu(2+), the solution displayed a colorimetric change from pale yellow to pink which is discernible by the naked eye. Additionally, the fluorescence intensities of the sensor exhibited ratiometric changes for the detection of Cu(2+) at 490 and 615 nm under a single excitation wavelength of 350 nm, which corresponded to the emissions of coumarin and rhodamine B moieties, respectively. The fluorescence color change could be visualized from blue to pink. The limits of detection were determined to be as low as 0.50 and 0.47 μM for UV-vis and fluorescence measurements, respectively. More importantly, the sensor not only can recognize Cu(2+) and form a sensor-Cu(2+) complex but can also sequentially detect Arg with the resulting complex. The detection limits for Arg were as low as 0.60 μM (UV-vis measurement) and 0.33 μM (fluorescence measurement), respectively. A fluorescence imaging experiment in living cells demonstrated that the fabricated sensor could be utilized in ratiometric fluorescence imaging towards intracellular Cu(2+), which is promising for the detection of low-level Cu(2+) and Arg with potentially practical significance.
format Online
Article
Text
id pubmed-9060912
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90609122022-05-04 A colorimetric and ratiometric fluorescent sensor for sequentially detecting Cu(2+) and arginine based on a coumarin–rhodamine B derivative and its application for bioimaging Wang, Shuai Ding, Haichang Wang, Yuesong Fan, Congbin Liu, Gang Pu, Shouzhi RSC Adv Chemistry In this work, a colorimetric and ratiometric fluorescent sensor based on a coumarin–rhodamine B hybrid for the sequential recognition of Cu(2+) and arginine (Arg) via the FRET mechanism was designed and synthesized. With the addition of Cu(2+), the solution displayed a colorimetric change from pale yellow to pink which is discernible by the naked eye. Additionally, the fluorescence intensities of the sensor exhibited ratiometric changes for the detection of Cu(2+) at 490 and 615 nm under a single excitation wavelength of 350 nm, which corresponded to the emissions of coumarin and rhodamine B moieties, respectively. The fluorescence color change could be visualized from blue to pink. The limits of detection were determined to be as low as 0.50 and 0.47 μM for UV-vis and fluorescence measurements, respectively. More importantly, the sensor not only can recognize Cu(2+) and form a sensor-Cu(2+) complex but can also sequentially detect Arg with the resulting complex. The detection limits for Arg were as low as 0.60 μM (UV-vis measurement) and 0.33 μM (fluorescence measurement), respectively. A fluorescence imaging experiment in living cells demonstrated that the fabricated sensor could be utilized in ratiometric fluorescence imaging towards intracellular Cu(2+), which is promising for the detection of low-level Cu(2+) and Arg with potentially practical significance. The Royal Society of Chemistry 2019-02-26 /pmc/articles/PMC9060912/ /pubmed/35518477 http://dx.doi.org/10.1039/c8ra09943j Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Wang, Shuai
Ding, Haichang
Wang, Yuesong
Fan, Congbin
Liu, Gang
Pu, Shouzhi
A colorimetric and ratiometric fluorescent sensor for sequentially detecting Cu(2+) and arginine based on a coumarin–rhodamine B derivative and its application for bioimaging
title A colorimetric and ratiometric fluorescent sensor for sequentially detecting Cu(2+) and arginine based on a coumarin–rhodamine B derivative and its application for bioimaging
title_full A colorimetric and ratiometric fluorescent sensor for sequentially detecting Cu(2+) and arginine based on a coumarin–rhodamine B derivative and its application for bioimaging
title_fullStr A colorimetric and ratiometric fluorescent sensor for sequentially detecting Cu(2+) and arginine based on a coumarin–rhodamine B derivative and its application for bioimaging
title_full_unstemmed A colorimetric and ratiometric fluorescent sensor for sequentially detecting Cu(2+) and arginine based on a coumarin–rhodamine B derivative and its application for bioimaging
title_short A colorimetric and ratiometric fluorescent sensor for sequentially detecting Cu(2+) and arginine based on a coumarin–rhodamine B derivative and its application for bioimaging
title_sort colorimetric and ratiometric fluorescent sensor for sequentially detecting cu(2+) and arginine based on a coumarin–rhodamine b derivative and its application for bioimaging
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9060912/
https://www.ncbi.nlm.nih.gov/pubmed/35518477
http://dx.doi.org/10.1039/c8ra09943j
work_keys_str_mv AT wangshuai acolorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT dinghaichang acolorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT wangyuesong acolorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT fancongbin acolorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT liugang acolorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT pushouzhi acolorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT wangshuai colorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT dinghaichang colorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT wangyuesong colorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT fancongbin colorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT liugang colorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging
AT pushouzhi colorimetricandratiometricfluorescentsensorforsequentiallydetectingcu2andargininebasedonacoumarinrhodaminebderivativeanditsapplicationforbioimaging