Cargando…

Endovascular Repair for Ascending Aortic Graft Side Branch Pseudoaneurysm: A Report of Two Cases

INTRODUCTION: A pseudoaneurysm arising from the side branch of the prosthesis, following ascending aortic replacement, is extremely rare. Re-intervention usually involves open surgery, replacement of the ascending aorta, or ligation of the side branch. Redo surgery with an additional sternotomy carr...

Descripción completa

Detalles Bibliográficos
Autores principales: Nomura, Yoshikatsu, Koide, Yutaka, Kawasaki, Ryota, Murakami, Hirohisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9062449/
https://www.ncbi.nlm.nih.gov/pubmed/35515008
http://dx.doi.org/10.1016/j.ejvsvf.2022.03.009
_version_ 1784698944257785856
author Nomura, Yoshikatsu
Koide, Yutaka
Kawasaki, Ryota
Murakami, Hirohisa
author_facet Nomura, Yoshikatsu
Koide, Yutaka
Kawasaki, Ryota
Murakami, Hirohisa
author_sort Nomura, Yoshikatsu
collection PubMed
description INTRODUCTION: A pseudoaneurysm arising from the side branch of the prosthesis, following ascending aortic replacement, is extremely rare. Re-intervention usually involves open surgery, replacement of the ascending aorta, or ligation of the side branch. Redo surgery with an additional sternotomy carries the risk of cardiac and vascular injuries, and endovascular treatment can reduce such adverse events. REPORT: This study describes the successful thoracic endovascular aortic repair (TEVAR) of two cases of pseudoaneurysms arising from the side branch after ascending aortic replacement. Case 1 involved a 79 year old man who underwent ascending aortic replacement and omentopexy for a ruptured tuberculous aortic aneurysm 13 years ago. The pseudoaneurysm was mushroom shaped with a 30 mm protrusion. Case 2 involved an 83 year old man who underwent ascending aortic replacement for Stanford type A acute aortic dissection 11 years ago. The pseudoaneurysm was rod shaped with a 27 mm protrusion. In both cases, the pseudoaneurysm arising from the side branch was not noted on computed tomography (CT) until one year earlier and was first identified at a routine follow up examination. The pseudoaneurysms required surgical repair because of the risk of rupture; however, TEVAR was selected considering the risks of redo surgery and the patients’ ages. It was performed via a femoral artery approach without adverse events using a commercially available thoracic aortic device. Post-operative CT scan showed complete exclusion of the pseudoaneurysm. DISCUSSION: Although TEVAR is usually not indicated for ascending aortic pathologies, if there is an anatomical indication and a compatible stent graft, TEVAR for the ascending aorta should be the first choice in patients who are inoperable, at high risk and undergoing redo surgery.
format Online
Article
Text
id pubmed-9062449
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-90624492022-05-04 Endovascular Repair for Ascending Aortic Graft Side Branch Pseudoaneurysm: A Report of Two Cases Nomura, Yoshikatsu Koide, Yutaka Kawasaki, Ryota Murakami, Hirohisa EJVES Vasc Forum Case Report INTRODUCTION: A pseudoaneurysm arising from the side branch of the prosthesis, following ascending aortic replacement, is extremely rare. Re-intervention usually involves open surgery, replacement of the ascending aorta, or ligation of the side branch. Redo surgery with an additional sternotomy carries the risk of cardiac and vascular injuries, and endovascular treatment can reduce such adverse events. REPORT: This study describes the successful thoracic endovascular aortic repair (TEVAR) of two cases of pseudoaneurysms arising from the side branch after ascending aortic replacement. Case 1 involved a 79 year old man who underwent ascending aortic replacement and omentopexy for a ruptured tuberculous aortic aneurysm 13 years ago. The pseudoaneurysm was mushroom shaped with a 30 mm protrusion. Case 2 involved an 83 year old man who underwent ascending aortic replacement for Stanford type A acute aortic dissection 11 years ago. The pseudoaneurysm was rod shaped with a 27 mm protrusion. In both cases, the pseudoaneurysm arising from the side branch was not noted on computed tomography (CT) until one year earlier and was first identified at a routine follow up examination. The pseudoaneurysms required surgical repair because of the risk of rupture; however, TEVAR was selected considering the risks of redo surgery and the patients’ ages. It was performed via a femoral artery approach without adverse events using a commercially available thoracic aortic device. Post-operative CT scan showed complete exclusion of the pseudoaneurysm. DISCUSSION: Although TEVAR is usually not indicated for ascending aortic pathologies, if there is an anatomical indication and a compatible stent graft, TEVAR for the ascending aorta should be the first choice in patients who are inoperable, at high risk and undergoing redo surgery. Elsevier 2022-04-13 /pmc/articles/PMC9062449/ /pubmed/35515008 http://dx.doi.org/10.1016/j.ejvsvf.2022.03.009 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Nomura, Yoshikatsu
Koide, Yutaka
Kawasaki, Ryota
Murakami, Hirohisa
Endovascular Repair for Ascending Aortic Graft Side Branch Pseudoaneurysm: A Report of Two Cases
title Endovascular Repair for Ascending Aortic Graft Side Branch Pseudoaneurysm: A Report of Two Cases
title_full Endovascular Repair for Ascending Aortic Graft Side Branch Pseudoaneurysm: A Report of Two Cases
title_fullStr Endovascular Repair for Ascending Aortic Graft Side Branch Pseudoaneurysm: A Report of Two Cases
title_full_unstemmed Endovascular Repair for Ascending Aortic Graft Side Branch Pseudoaneurysm: A Report of Two Cases
title_short Endovascular Repair for Ascending Aortic Graft Side Branch Pseudoaneurysm: A Report of Two Cases
title_sort endovascular repair for ascending aortic graft side branch pseudoaneurysm: a report of two cases
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9062449/
https://www.ncbi.nlm.nih.gov/pubmed/35515008
http://dx.doi.org/10.1016/j.ejvsvf.2022.03.009
work_keys_str_mv AT nomurayoshikatsu endovascularrepairforascendingaorticgraftsidebranchpseudoaneurysmareportoftwocases
AT koideyutaka endovascularrepairforascendingaorticgraftsidebranchpseudoaneurysmareportoftwocases
AT kawasakiryota endovascularrepairforascendingaorticgraftsidebranchpseudoaneurysmareportoftwocases
AT murakamihirohisa endovascularrepairforascendingaorticgraftsidebranchpseudoaneurysmareportoftwocases