Cargando…

Fabrication of Tween-20 coated PVDF membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance

In the present study, polyoxyethylene (20) sorbitan monolaurate (Tween-20) was employed as a surface coating agent for hydrophilic modification of poly(vinylidene fluoride) microfiltration membranes. The optimized parameters for membrane preparation (i.e., coating temperature, coating concentration,...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Daoji, Zhou, Weiwei, Cheng, Xiaoxiang, Luo, Congwei, Li, Peijie, Zhang, Fengzhi, Ren, Zixiao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9065567/
https://www.ncbi.nlm.nih.gov/pubmed/35514714
http://dx.doi.org/10.1039/c9ra03549d
_version_ 1784699610798751744
author Wu, Daoji
Zhou, Weiwei
Cheng, Xiaoxiang
Luo, Congwei
Li, Peijie
Zhang, Fengzhi
Ren, Zixiao
author_facet Wu, Daoji
Zhou, Weiwei
Cheng, Xiaoxiang
Luo, Congwei
Li, Peijie
Zhang, Fengzhi
Ren, Zixiao
author_sort Wu, Daoji
collection PubMed
description In the present study, polyoxyethylene (20) sorbitan monolaurate (Tween-20) was employed as a surface coating agent for hydrophilic modification of poly(vinylidene fluoride) microfiltration membranes. The optimized parameters for membrane preparation (i.e., coating temperature, coating concentration, coating time and drying time) were systematically investigated. Contact angle and transmembrane pressure were employed to evaluate the efficiency of the modified membranes, and the optimized parameters were proposed. The removal of chemical oxygen demand (COD) and suspended solids (SS), as well as fouling control performance, was further evaluated. The results showed that the optimized parameters were 40 °C, 4.5 mmol L(−1), 45 min and 45 min for coating temperature, coating concentration, coating time and drying time, respectively. Under these conditions, a hydration layer on the surface was formed, resulting in a more hydrophilic membrane surface. During domestic wastewater treatment in membrane bioreactor (MBR), the Tween-20 modified membrane exhibited better performance with rejection efficiencies of 94.56% and 97.53% for COD and SS, respectively. Tween-20 coating could mitigate the increase of transmembrane pressure and reduce the concentration of proteins accumulated on the membrane surface, which was effective for membrane fouling control. Simultaneously, the operation time of MBR was extended from 25 to 46 days. Furthermore, the stability of Tween-20 coated PVDF membrane was also verified. The results indicated that surface coating with Tween-20 is efficient and easy to be carried out, showing a great potential for application in MBR during wastewater treatment.
format Online
Article
Text
id pubmed-9065567
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90655672022-05-04 Fabrication of Tween-20 coated PVDF membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance Wu, Daoji Zhou, Weiwei Cheng, Xiaoxiang Luo, Congwei Li, Peijie Zhang, Fengzhi Ren, Zixiao RSC Adv Chemistry In the present study, polyoxyethylene (20) sorbitan monolaurate (Tween-20) was employed as a surface coating agent for hydrophilic modification of poly(vinylidene fluoride) microfiltration membranes. The optimized parameters for membrane preparation (i.e., coating temperature, coating concentration, coating time and drying time) were systematically investigated. Contact angle and transmembrane pressure were employed to evaluate the efficiency of the modified membranes, and the optimized parameters were proposed. The removal of chemical oxygen demand (COD) and suspended solids (SS), as well as fouling control performance, was further evaluated. The results showed that the optimized parameters were 40 °C, 4.5 mmol L(−1), 45 min and 45 min for coating temperature, coating concentration, coating time and drying time, respectively. Under these conditions, a hydration layer on the surface was formed, resulting in a more hydrophilic membrane surface. During domestic wastewater treatment in membrane bioreactor (MBR), the Tween-20 modified membrane exhibited better performance with rejection efficiencies of 94.56% and 97.53% for COD and SS, respectively. Tween-20 coating could mitigate the increase of transmembrane pressure and reduce the concentration of proteins accumulated on the membrane surface, which was effective for membrane fouling control. Simultaneously, the operation time of MBR was extended from 25 to 46 days. Furthermore, the stability of Tween-20 coated PVDF membrane was also verified. The results indicated that surface coating with Tween-20 is efficient and easy to be carried out, showing a great potential for application in MBR during wastewater treatment. The Royal Society of Chemistry 2019-06-27 /pmc/articles/PMC9065567/ /pubmed/35514714 http://dx.doi.org/10.1039/c9ra03549d Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Wu, Daoji
Zhou, Weiwei
Cheng, Xiaoxiang
Luo, Congwei
Li, Peijie
Zhang, Fengzhi
Ren, Zixiao
Fabrication of Tween-20 coated PVDF membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance
title Fabrication of Tween-20 coated PVDF membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance
title_full Fabrication of Tween-20 coated PVDF membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance
title_fullStr Fabrication of Tween-20 coated PVDF membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance
title_full_unstemmed Fabrication of Tween-20 coated PVDF membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance
title_short Fabrication of Tween-20 coated PVDF membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance
title_sort fabrication of tween-20 coated pvdf membranes for wastewater treatment: optimization of preparation parameters, removal and membrane fouling control performance
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9065567/
https://www.ncbi.nlm.nih.gov/pubmed/35514714
http://dx.doi.org/10.1039/c9ra03549d
work_keys_str_mv AT wudaoji fabricationoftween20coatedpvdfmembranesforwastewatertreatmentoptimizationofpreparationparametersremovalandmembranefoulingcontrolperformance
AT zhouweiwei fabricationoftween20coatedpvdfmembranesforwastewatertreatmentoptimizationofpreparationparametersremovalandmembranefoulingcontrolperformance
AT chengxiaoxiang fabricationoftween20coatedpvdfmembranesforwastewatertreatmentoptimizationofpreparationparametersremovalandmembranefoulingcontrolperformance
AT luocongwei fabricationoftween20coatedpvdfmembranesforwastewatertreatmentoptimizationofpreparationparametersremovalandmembranefoulingcontrolperformance
AT lipeijie fabricationoftween20coatedpvdfmembranesforwastewatertreatmentoptimizationofpreparationparametersremovalandmembranefoulingcontrolperformance
AT zhangfengzhi fabricationoftween20coatedpvdfmembranesforwastewatertreatmentoptimizationofpreparationparametersremovalandmembranefoulingcontrolperformance
AT renzixiao fabricationoftween20coatedpvdfmembranesforwastewatertreatmentoptimizationofpreparationparametersremovalandmembranefoulingcontrolperformance