Cargando…

Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats

A novel laser- and impedance-based point-of-care hematology analyzer (POCA), the vCell 5 (scil Animal Care), providing a complete blood count with 5-part leukocyte differential count has recently been introduced to veterinary laboratories. We evaluated the analyzer for use in dogs and cats including...

Descripción completa

Detalles Bibliográficos
Autores principales: Zelmer, Kim-Lina Charlotte, Bauer, Natali, Moritz, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9066672/
https://www.ncbi.nlm.nih.gov/pubmed/35331075
http://dx.doi.org/10.1177/10406387221083621
_version_ 1784699844372201472
author Zelmer, Kim-Lina Charlotte
Bauer, Natali
Moritz, Andreas
author_facet Zelmer, Kim-Lina Charlotte
Bauer, Natali
Moritz, Andreas
author_sort Zelmer, Kim-Lina Charlotte
collection PubMed
description A novel laser- and impedance-based point-of-care hematology analyzer (POCA), the vCell 5 (scil Animal Care), providing a complete blood count with 5-part leukocyte differential count has recently been introduced to veterinary laboratories. We evaluated the analyzer for use in dogs and cats including method comparison and assessment of linearity, carryover, and precision. Fresh blood samples from 192 healthy and diseased dogs and 159 cats were analyzed, and results were compared to reference methods (i.e., microhematocrit [PCV], Advia 2120 hematology analyzer). Total observed error (TEo) was calculated from CV, obtained at 3 concentrations, and bias%, and compared to total allowable error (TEa). For both species, excellent correlation (r(s) = 0.93–0.99) was seen between methods for WBC and RBC, hematocrit, hemoglobin, and platelet counts (PLT), except for feline PLT (r(s) = 0.79). Quality requirements (TEo < TEa) were fulfilled for WBC (TEo = 8.6–11.1%; TEa = 20%) and RBC (TEo = 3.5–7%; TEa = 10%), hematocrit (TEo = 5.7–9.4%; TEa = 10%), PCV (cat TEo = 7.8%; TEa = 10%), mean corpuscular volume (cat TEo = 5.1%; TEa = 7%), and PLT (TEo = 13.1–24.1%; TEa = 25%). Excellent linearity was demonstrated for WBC, RBC, and PLT, and hemoglobin. CVs of <2% for WBC, RBC, hematocrit, hemoglobin, and of <5% (dog) and 8% (cat) for PLT were demonstrated for values within the RI. Except for calculated variables and well-known species-specific deviations in feline PLT, scil POCA results were correlated favorably with reference method results and complied with quality requirements for cats and dogs.
format Online
Article
Text
id pubmed-9066672
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-90666722022-05-04 Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats Zelmer, Kim-Lina Charlotte Bauer, Natali Moritz, Andreas J Vet Diagn Invest Full Scientific Reports A novel laser- and impedance-based point-of-care hematology analyzer (POCA), the vCell 5 (scil Animal Care), providing a complete blood count with 5-part leukocyte differential count has recently been introduced to veterinary laboratories. We evaluated the analyzer for use in dogs and cats including method comparison and assessment of linearity, carryover, and precision. Fresh blood samples from 192 healthy and diseased dogs and 159 cats were analyzed, and results were compared to reference methods (i.e., microhematocrit [PCV], Advia 2120 hematology analyzer). Total observed error (TEo) was calculated from CV, obtained at 3 concentrations, and bias%, and compared to total allowable error (TEa). For both species, excellent correlation (r(s) = 0.93–0.99) was seen between methods for WBC and RBC, hematocrit, hemoglobin, and platelet counts (PLT), except for feline PLT (r(s) = 0.79). Quality requirements (TEo < TEa) were fulfilled for WBC (TEo = 8.6–11.1%; TEa = 20%) and RBC (TEo = 3.5–7%; TEa = 10%), hematocrit (TEo = 5.7–9.4%; TEa = 10%), PCV (cat TEo = 7.8%; TEa = 10%), mean corpuscular volume (cat TEo = 5.1%; TEa = 7%), and PLT (TEo = 13.1–24.1%; TEa = 25%). Excellent linearity was demonstrated for WBC, RBC, and PLT, and hemoglobin. CVs of <2% for WBC, RBC, hematocrit, hemoglobin, and of <5% (dog) and 8% (cat) for PLT were demonstrated for values within the RI. Except for calculated variables and well-known species-specific deviations in feline PLT, scil POCA results were correlated favorably with reference method results and complied with quality requirements for cats and dogs. SAGE Publications 2022-03-24 2022-05 /pmc/articles/PMC9066672/ /pubmed/35331075 http://dx.doi.org/10.1177/10406387221083621 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Full Scientific Reports
Zelmer, Kim-Lina Charlotte
Bauer, Natali
Moritz, Andreas
Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats
title Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats
title_full Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats
title_fullStr Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats
title_full_unstemmed Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats
title_short Evaluation of the scil vCell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats
title_sort evaluation of the scil vcell 5, a novel laser- and impedance-based point-of-care hematology analyzer, for use in dogs and cats
topic Full Scientific Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9066672/
https://www.ncbi.nlm.nih.gov/pubmed/35331075
http://dx.doi.org/10.1177/10406387221083621
work_keys_str_mv AT zelmerkimlinacharlotte evaluationofthescilvcell5anovellaserandimpedancebasedpointofcarehematologyanalyzerforuseindogsandcats
AT bauernatali evaluationofthescilvcell5anovellaserandimpedancebasedpointofcarehematologyanalyzerforuseindogsandcats
AT moritzandreas evaluationofthescilvcell5anovellaserandimpedancebasedpointofcarehematologyanalyzerforuseindogsandcats