Cargando…
CRISPR-Cas12a combination to alleviate the false-positive in loop-mediated isothermal amplification-based diagnosis of Neisseria meningitidis
BACKGROUND: Loop isothermal amplification (LAMP) has recently been proposed as a point-of-care diagnostic tool to detect acute infectious pathogens; however, this technique embeds risk of generating false-positive results. Whereas, with abilities to accurately recognize specific sequence, the CRISPR...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9066958/ https://www.ncbi.nlm.nih.gov/pubmed/35508977 http://dx.doi.org/10.1186/s12879-022-07363-w |
_version_ | 1784699906343043072 |
---|---|
author | Trung, Ngo Tat Son, Le Huu Phuc Hien, Trinh Xuan Quyen, Dao Thanh Bang, Mai Hong Song, Le Huu |
author_facet | Trung, Ngo Tat Son, Le Huu Phuc Hien, Trinh Xuan Quyen, Dao Thanh Bang, Mai Hong Song, Le Huu |
author_sort | Trung, Ngo Tat |
collection | PubMed |
description | BACKGROUND: Loop isothermal amplification (LAMP) has recently been proposed as a point-of-care diagnostic tool to detect acute infectious pathogens; however, this technique embeds risk of generating false-positive results. Whereas, with abilities to accurately recognize specific sequence, the CRISPR/Cas12a can forms complexes with cognate RNA sensors and cleave pathogen’s DNA targets complimerntary to its cognate RNA, afterward acquiring the collateral activity to unbiasedly cut nearby off-target fragments. Therefore, if relevant fluorescent-quencher-nucleic probes are present in the reaction, the non-specific cleavage of probes releases fluorescences and establish diagnostic read-outs. METHODS: The MetA gene of N. meningitidis was selected as target to optimize the LAMP reaction, whereas pseudo-dilution series of N. meningitidis gemonics DNA was used to establish the detection limit of LAMP/Cas12a combination assay. The diagnostic performance of established LAMP/Cas12a combination assay was validated in comparation with standard real-time PCR on 51 CSF samples (14 N. meningitidis confirmed patients and 37 control subjects). RESULTS: In relevant biochemical conditions, CRISPR-Cas12a and LAMP can work synchronously to accurately identify genetics materials of Nesseria menitigistis at the level 40 copies/reaction less than 2 h. CONCLUSIONS: In properly optimized conditions, the CRISPR-Cas12a system helps to alleviate false positive result hence enhancing the specificity of the LAMP assays. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12879-022-07363-w. |
format | Online Article Text |
id | pubmed-9066958 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-90669582022-05-04 CRISPR-Cas12a combination to alleviate the false-positive in loop-mediated isothermal amplification-based diagnosis of Neisseria meningitidis Trung, Ngo Tat Son, Le Huu Phuc Hien, Trinh Xuan Quyen, Dao Thanh Bang, Mai Hong Song, Le Huu BMC Infect Dis Technical Advance BACKGROUND: Loop isothermal amplification (LAMP) has recently been proposed as a point-of-care diagnostic tool to detect acute infectious pathogens; however, this technique embeds risk of generating false-positive results. Whereas, with abilities to accurately recognize specific sequence, the CRISPR/Cas12a can forms complexes with cognate RNA sensors and cleave pathogen’s DNA targets complimerntary to its cognate RNA, afterward acquiring the collateral activity to unbiasedly cut nearby off-target fragments. Therefore, if relevant fluorescent-quencher-nucleic probes are present in the reaction, the non-specific cleavage of probes releases fluorescences and establish diagnostic read-outs. METHODS: The MetA gene of N. meningitidis was selected as target to optimize the LAMP reaction, whereas pseudo-dilution series of N. meningitidis gemonics DNA was used to establish the detection limit of LAMP/Cas12a combination assay. The diagnostic performance of established LAMP/Cas12a combination assay was validated in comparation with standard real-time PCR on 51 CSF samples (14 N. meningitidis confirmed patients and 37 control subjects). RESULTS: In relevant biochemical conditions, CRISPR-Cas12a and LAMP can work synchronously to accurately identify genetics materials of Nesseria menitigistis at the level 40 copies/reaction less than 2 h. CONCLUSIONS: In properly optimized conditions, the CRISPR-Cas12a system helps to alleviate false positive result hence enhancing the specificity of the LAMP assays. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12879-022-07363-w. BioMed Central 2022-05-04 /pmc/articles/PMC9066958/ /pubmed/35508977 http://dx.doi.org/10.1186/s12879-022-07363-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visithttp://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Technical Advance Trung, Ngo Tat Son, Le Huu Phuc Hien, Trinh Xuan Quyen, Dao Thanh Bang, Mai Hong Song, Le Huu CRISPR-Cas12a combination to alleviate the false-positive in loop-mediated isothermal amplification-based diagnosis of Neisseria meningitidis |
title | CRISPR-Cas12a combination to alleviate the false-positive in loop-mediated isothermal amplification-based diagnosis of Neisseria meningitidis |
title_full | CRISPR-Cas12a combination to alleviate the false-positive in loop-mediated isothermal amplification-based diagnosis of Neisseria meningitidis |
title_fullStr | CRISPR-Cas12a combination to alleviate the false-positive in loop-mediated isothermal amplification-based diagnosis of Neisseria meningitidis |
title_full_unstemmed | CRISPR-Cas12a combination to alleviate the false-positive in loop-mediated isothermal amplification-based diagnosis of Neisseria meningitidis |
title_short | CRISPR-Cas12a combination to alleviate the false-positive in loop-mediated isothermal amplification-based diagnosis of Neisseria meningitidis |
title_sort | crispr-cas12a combination to alleviate the false-positive in loop-mediated isothermal amplification-based diagnosis of neisseria meningitidis |
topic | Technical Advance |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9066958/ https://www.ncbi.nlm.nih.gov/pubmed/35508977 http://dx.doi.org/10.1186/s12879-022-07363-w |
work_keys_str_mv | AT trungngotat crisprcas12acombinationtoalleviatethefalsepositiveinloopmediatedisothermalamplificationbaseddiagnosisofneisseriameningitidis AT sonlehuuphuc crisprcas12acombinationtoalleviatethefalsepositiveinloopmediatedisothermalamplificationbaseddiagnosisofneisseriameningitidis AT hientrinhxuan crisprcas12acombinationtoalleviatethefalsepositiveinloopmediatedisothermalamplificationbaseddiagnosisofneisseriameningitidis AT quyendaothanh crisprcas12acombinationtoalleviatethefalsepositiveinloopmediatedisothermalamplificationbaseddiagnosisofneisseriameningitidis AT bangmaihong crisprcas12acombinationtoalleviatethefalsepositiveinloopmediatedisothermalamplificationbaseddiagnosisofneisseriameningitidis AT songlehuu crisprcas12acombinationtoalleviatethefalsepositiveinloopmediatedisothermalamplificationbaseddiagnosisofneisseriameningitidis |