Cargando…

Evaluation of the Combination of Artificial Intelligence and Radiologist Assessments to Interpret Malignant Architectural Distortion on Mammography

PURPOSE: To compare the mammographic malignant architectural distortion (AD) detection performance of radiologists who read mammographic examinations unaided versus those who read these examinations with the support of artificial intelligence (AI) systems. MATERIAL AND METHODS: This retrospective ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Wan, Yun, Tong, Yunfei, Liu, Yuanyuan, Huang, Yan, Yao, Guoyan, Chen, Daniel Q., Liu, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9067265/
https://www.ncbi.nlm.nih.gov/pubmed/35515107
http://dx.doi.org/10.3389/fonc.2022.880150
_version_ 1784699970714075136
author Wan, Yun
Tong, Yunfei
Liu, Yuanyuan
Huang, Yan
Yao, Guoyan
Chen, Daniel Q.
Liu, Bo
author_facet Wan, Yun
Tong, Yunfei
Liu, Yuanyuan
Huang, Yan
Yao, Guoyan
Chen, Daniel Q.
Liu, Bo
author_sort Wan, Yun
collection PubMed
description PURPOSE: To compare the mammographic malignant architectural distortion (AD) detection performance of radiologists who read mammographic examinations unaided versus those who read these examinations with the support of artificial intelligence (AI) systems. MATERIAL AND METHODS: This retrospective case-control study was based on a double-reading of clinical mammograms between January 2011 and December 2016 at a large tertiary academic medical center. The study included 177 malignant and 90 benign architectural distortion (AD) patients. The model was built based on the ResNeXt-50 network. Algorithms used deep learning convolutional neural networks, feature classifiers, image analysis algorithms to depict AD and output a score that translated to malignant. The accuracy for malignant AD detection was evaluated using area under the curve (AUC). RESULTS: The overall AUC was 0.733 (95% CI, 0.673-0.792) for Reader First-1, 0.652 (95% CI, 0.586-0.717) for Reader First-2, and 0.655 (95% CI, 0.590-0.719) for Reader First-3. and the overall AUCs for Reader Second-1, 2, 3 were 0.875 (95% CI, 0.830-0.919), 0.882 (95% CI, 0.839-0.926), 0.884 (95% CI, 0.841-0.927),respectively. The AUCs for all the reader-second radiologists were significantly higher than those for all the reader-first radiologists (Reader First-1 vs. Reader Second-1, P= 0.004). The overall AUC was 0.792 (95% CI, 0.660-0.925) for AI algorithms. The combination assessment of AI algorithms and Reader First-1 achieved an AUC of 0.880 (95% CI, 0.793-0.968), increased than the Reader First-1 alone and AI algorithms alone. AI algorithms alone achieved a specificity of 61.1% and a sensitivity of 80.6%. The specificity for Reader First-1 was 55.5%, and the sensitivity was 86.1%. The results of the combined assessment of AI and Reader First-1 showed a specificity of 72.7% and sensitivity of 91.7%. The performance showed significant improvements compared with AI alone (p<0.001) as well as the reader first-1 alone (p=0.006). CONCLUSION: While the single AI algorithm did not outperform radiologists, an ensemble of AI algorithms combined with junior radiologist assessments were found to improve the overall accuracy. This study underscores the potential of using machine learning methods to enhance mammography interpretation, especially in remote areas and primary hospitals.
format Online
Article
Text
id pubmed-9067265
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-90672652022-05-04 Evaluation of the Combination of Artificial Intelligence and Radiologist Assessments to Interpret Malignant Architectural Distortion on Mammography Wan, Yun Tong, Yunfei Liu, Yuanyuan Huang, Yan Yao, Guoyan Chen, Daniel Q. Liu, Bo Front Oncol Oncology PURPOSE: To compare the mammographic malignant architectural distortion (AD) detection performance of radiologists who read mammographic examinations unaided versus those who read these examinations with the support of artificial intelligence (AI) systems. MATERIAL AND METHODS: This retrospective case-control study was based on a double-reading of clinical mammograms between January 2011 and December 2016 at a large tertiary academic medical center. The study included 177 malignant and 90 benign architectural distortion (AD) patients. The model was built based on the ResNeXt-50 network. Algorithms used deep learning convolutional neural networks, feature classifiers, image analysis algorithms to depict AD and output a score that translated to malignant. The accuracy for malignant AD detection was evaluated using area under the curve (AUC). RESULTS: The overall AUC was 0.733 (95% CI, 0.673-0.792) for Reader First-1, 0.652 (95% CI, 0.586-0.717) for Reader First-2, and 0.655 (95% CI, 0.590-0.719) for Reader First-3. and the overall AUCs for Reader Second-1, 2, 3 were 0.875 (95% CI, 0.830-0.919), 0.882 (95% CI, 0.839-0.926), 0.884 (95% CI, 0.841-0.927),respectively. The AUCs for all the reader-second radiologists were significantly higher than those for all the reader-first radiologists (Reader First-1 vs. Reader Second-1, P= 0.004). The overall AUC was 0.792 (95% CI, 0.660-0.925) for AI algorithms. The combination assessment of AI algorithms and Reader First-1 achieved an AUC of 0.880 (95% CI, 0.793-0.968), increased than the Reader First-1 alone and AI algorithms alone. AI algorithms alone achieved a specificity of 61.1% and a sensitivity of 80.6%. The specificity for Reader First-1 was 55.5%, and the sensitivity was 86.1%. The results of the combined assessment of AI and Reader First-1 showed a specificity of 72.7% and sensitivity of 91.7%. The performance showed significant improvements compared with AI alone (p<0.001) as well as the reader first-1 alone (p=0.006). CONCLUSION: While the single AI algorithm did not outperform radiologists, an ensemble of AI algorithms combined with junior radiologist assessments were found to improve the overall accuracy. This study underscores the potential of using machine learning methods to enhance mammography interpretation, especially in remote areas and primary hospitals. Frontiers Media S.A. 2022-04-20 /pmc/articles/PMC9067265/ /pubmed/35515107 http://dx.doi.org/10.3389/fonc.2022.880150 Text en Copyright © 2022 Wan, Tong, Liu, Huang, Yao, Chen and Liu https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Wan, Yun
Tong, Yunfei
Liu, Yuanyuan
Huang, Yan
Yao, Guoyan
Chen, Daniel Q.
Liu, Bo
Evaluation of the Combination of Artificial Intelligence and Radiologist Assessments to Interpret Malignant Architectural Distortion on Mammography
title Evaluation of the Combination of Artificial Intelligence and Radiologist Assessments to Interpret Malignant Architectural Distortion on Mammography
title_full Evaluation of the Combination of Artificial Intelligence and Radiologist Assessments to Interpret Malignant Architectural Distortion on Mammography
title_fullStr Evaluation of the Combination of Artificial Intelligence and Radiologist Assessments to Interpret Malignant Architectural Distortion on Mammography
title_full_unstemmed Evaluation of the Combination of Artificial Intelligence and Radiologist Assessments to Interpret Malignant Architectural Distortion on Mammography
title_short Evaluation of the Combination of Artificial Intelligence and Radiologist Assessments to Interpret Malignant Architectural Distortion on Mammography
title_sort evaluation of the combination of artificial intelligence and radiologist assessments to interpret malignant architectural distortion on mammography
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9067265/
https://www.ncbi.nlm.nih.gov/pubmed/35515107
http://dx.doi.org/10.3389/fonc.2022.880150
work_keys_str_mv AT wanyun evaluationofthecombinationofartificialintelligenceandradiologistassessmentstointerpretmalignantarchitecturaldistortiononmammography
AT tongyunfei evaluationofthecombinationofartificialintelligenceandradiologistassessmentstointerpretmalignantarchitecturaldistortiononmammography
AT liuyuanyuan evaluationofthecombinationofartificialintelligenceandradiologistassessmentstointerpretmalignantarchitecturaldistortiononmammography
AT huangyan evaluationofthecombinationofartificialintelligenceandradiologistassessmentstointerpretmalignantarchitecturaldistortiononmammography
AT yaoguoyan evaluationofthecombinationofartificialintelligenceandradiologistassessmentstointerpretmalignantarchitecturaldistortiononmammography
AT chendanielq evaluationofthecombinationofartificialintelligenceandradiologistassessmentstointerpretmalignantarchitecturaldistortiononmammography
AT liubo evaluationofthecombinationofartificialintelligenceandradiologistassessmentstointerpretmalignantarchitecturaldistortiononmammography