Cargando…

An Evaluation of Phosphate Buffer Saline as an Alternative Liquid-Based Medium for HPV DNA Detection

OBJECTIVE: HPV detection has been proposed as part of the co-testing which improves the sensitivity of cervical screening. However, the commercially liquid-based medium adds cost in low-resource areas. This study aimed to evaluate the performance of ice-cold phosphate buffer saline (PBS) for HPV det...

Descripción completa

Detalles Bibliográficos
Autores principales: Dankai, Wiyada, Khunamornpong, Surapan, Siriaunkgul, Sumalee, Soongkhaw, Aungsumalee, Aithin, Phanlapa, Lekawanvijit, Suree
Formato: Online Artículo Texto
Lenguaje:English
Publicado: West Asia Organization for Cancer Prevention 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9068200/
https://www.ncbi.nlm.nih.gov/pubmed/34837897
http://dx.doi.org/10.31557/APJCP.2021.22.11.3441
_version_ 1784700176056713216
author Dankai, Wiyada
Khunamornpong, Surapan
Siriaunkgul, Sumalee
Soongkhaw, Aungsumalee
Aithin, Phanlapa
Lekawanvijit, Suree
author_facet Dankai, Wiyada
Khunamornpong, Surapan
Siriaunkgul, Sumalee
Soongkhaw, Aungsumalee
Aithin, Phanlapa
Lekawanvijit, Suree
author_sort Dankai, Wiyada
collection PubMed
description OBJECTIVE: HPV detection has been proposed as part of the co-testing which improves the sensitivity of cervical screening. However, the commercially liquid-based medium adds cost in low-resource areas. This study aimed to evaluate the performance of ice-cold phosphate buffer saline (PBS) for HPV detection. METHODS: HPV DNA from SiHa cells (with 1-2 copies of HPV16 per cell) preserved in ice-cold PBS or PreserveCyt solution at different time points (24, 36, 48, 72, 120 and 168 h) was tested in triplicate using Cobas 4800. The threshold cycle (Ct) values of both solutions were compared. An estimated false negative rate of PBS was also assessed by using the difference in Ct values between both solutions (∆Ct) and Ct values of HPV16-positive PreserveCyt clinical samples (Ctsample) at corresponding time points. Samples with a (Ctsample+∆Ct) value > 40.5 (the cutoff of HPV16 DNA by Cobas 4800) were considered as false negativity. RESULTS: The Ct values of HPV16 DNA of SiHa cells collected in PBS were higher than PreserveCyt ranging from 0.43 to 2.36 cycles depending on incubation times. There was no significant difference at 24, 72, 120, and 168 h. However, the Ct values were statistically significantly higher for PBS than PreserveCyt at 36 h (31.00 vs 29.26), and 48 h (31.06 vs 28.70). A retrospective analysis in 47 clinical PreserveCyt collected samples that were positive for HPV16 DNA found that 1 case (2%) would become negative if collected in ice-cold PBS. CONCLUSIONS: The PBS might be an alternative collecting medium for HPV detection in the low-resource areas. Further evaluations are warranted.
format Online
Article
Text
id pubmed-9068200
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher West Asia Organization for Cancer Prevention
record_format MEDLINE/PubMed
spelling pubmed-90682002022-05-06 An Evaluation of Phosphate Buffer Saline as an Alternative Liquid-Based Medium for HPV DNA Detection Dankai, Wiyada Khunamornpong, Surapan Siriaunkgul, Sumalee Soongkhaw, Aungsumalee Aithin, Phanlapa Lekawanvijit, Suree Asian Pac J Cancer Prev Research Article OBJECTIVE: HPV detection has been proposed as part of the co-testing which improves the sensitivity of cervical screening. However, the commercially liquid-based medium adds cost in low-resource areas. This study aimed to evaluate the performance of ice-cold phosphate buffer saline (PBS) for HPV detection. METHODS: HPV DNA from SiHa cells (with 1-2 copies of HPV16 per cell) preserved in ice-cold PBS or PreserveCyt solution at different time points (24, 36, 48, 72, 120 and 168 h) was tested in triplicate using Cobas 4800. The threshold cycle (Ct) values of both solutions were compared. An estimated false negative rate of PBS was also assessed by using the difference in Ct values between both solutions (∆Ct) and Ct values of HPV16-positive PreserveCyt clinical samples (Ctsample) at corresponding time points. Samples with a (Ctsample+∆Ct) value > 40.5 (the cutoff of HPV16 DNA by Cobas 4800) were considered as false negativity. RESULTS: The Ct values of HPV16 DNA of SiHa cells collected in PBS were higher than PreserveCyt ranging from 0.43 to 2.36 cycles depending on incubation times. There was no significant difference at 24, 72, 120, and 168 h. However, the Ct values were statistically significantly higher for PBS than PreserveCyt at 36 h (31.00 vs 29.26), and 48 h (31.06 vs 28.70). A retrospective analysis in 47 clinical PreserveCyt collected samples that were positive for HPV16 DNA found that 1 case (2%) would become negative if collected in ice-cold PBS. CONCLUSIONS: The PBS might be an alternative collecting medium for HPV detection in the low-resource areas. Further evaluations are warranted. West Asia Organization for Cancer Prevention 2021-11 /pmc/articles/PMC9068200/ /pubmed/34837897 http://dx.doi.org/10.31557/APJCP.2021.22.11.3441 Text en https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Dankai, Wiyada
Khunamornpong, Surapan
Siriaunkgul, Sumalee
Soongkhaw, Aungsumalee
Aithin, Phanlapa
Lekawanvijit, Suree
An Evaluation of Phosphate Buffer Saline as an Alternative Liquid-Based Medium for HPV DNA Detection
title An Evaluation of Phosphate Buffer Saline as an Alternative Liquid-Based Medium for HPV DNA Detection
title_full An Evaluation of Phosphate Buffer Saline as an Alternative Liquid-Based Medium for HPV DNA Detection
title_fullStr An Evaluation of Phosphate Buffer Saline as an Alternative Liquid-Based Medium for HPV DNA Detection
title_full_unstemmed An Evaluation of Phosphate Buffer Saline as an Alternative Liquid-Based Medium for HPV DNA Detection
title_short An Evaluation of Phosphate Buffer Saline as an Alternative Liquid-Based Medium for HPV DNA Detection
title_sort evaluation of phosphate buffer saline as an alternative liquid-based medium for hpv dna detection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9068200/
https://www.ncbi.nlm.nih.gov/pubmed/34837897
http://dx.doi.org/10.31557/APJCP.2021.22.11.3441
work_keys_str_mv AT dankaiwiyada anevaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT khunamornpongsurapan anevaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT siriaunkgulsumalee anevaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT soongkhawaungsumalee anevaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT aithinphanlapa anevaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT lekawanvijitsuree anevaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT dankaiwiyada evaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT khunamornpongsurapan evaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT siriaunkgulsumalee evaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT soongkhawaungsumalee evaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT aithinphanlapa evaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection
AT lekawanvijitsuree evaluationofphosphatebuffersalineasanalternativeliquidbasedmediumforhpvdnadetection