Cargando…
Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor
In order to improve the effect of on-the-spot diagnosis of senile cataract, this paper combines the intelligent processor to explore the application of color Doppler ultrasound in the clinical analysis of senile cataract. Moreover, this paper measures and calculates the diameter, perimeter, area, vo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9068292/ https://www.ncbi.nlm.nih.gov/pubmed/35529272 http://dx.doi.org/10.1155/2022/1037439 |
_version_ | 1784700193816444928 |
---|---|
author | Chen, Yanyan Xiao, Xuebing Wu, Lan Liu, Yang |
author_facet | Chen, Yanyan Xiao, Xuebing Wu, Lan Liu, Yang |
author_sort | Chen, Yanyan |
collection | PubMed |
description | In order to improve the effect of on-the-spot diagnosis of senile cataract, this paper combines the intelligent processor to explore the application of color Doppler ultrasound in the clinical analysis of senile cataract. Moreover, this paper measures and calculates the diameter, perimeter, area, volume, or velocity of blood flow reflected by color Doppler ultrasound images. In addition, this paper adopts the measurement method provided by composite measurement to design the intelligent processor. Each measurement analysis package is defined as an independent class, and the data, properties, and methods are encapsulated in a class, which is beneficial to the modular design of the program and the overall management of the system. The experimental results verify that the intelligent processor proposed in this paper has a certain effect in the clinical analysis of color Doppler ultrasound diagnosis of senile cataract. |
format | Online Article Text |
id | pubmed-9068292 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-90682922022-05-05 Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor Chen, Yanyan Xiao, Xuebing Wu, Lan Liu, Yang Comput Math Methods Med Research Article In order to improve the effect of on-the-spot diagnosis of senile cataract, this paper combines the intelligent processor to explore the application of color Doppler ultrasound in the clinical analysis of senile cataract. Moreover, this paper measures and calculates the diameter, perimeter, area, volume, or velocity of blood flow reflected by color Doppler ultrasound images. In addition, this paper adopts the measurement method provided by composite measurement to design the intelligent processor. Each measurement analysis package is defined as an independent class, and the data, properties, and methods are encapsulated in a class, which is beneficial to the modular design of the program and the overall management of the system. The experimental results verify that the intelligent processor proposed in this paper has a certain effect in the clinical analysis of color Doppler ultrasound diagnosis of senile cataract. Hindawi 2022-04-27 /pmc/articles/PMC9068292/ /pubmed/35529272 http://dx.doi.org/10.1155/2022/1037439 Text en Copyright © 2022 Yanyan Chen et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Chen, Yanyan Xiao, Xuebing Wu, Lan Liu, Yang Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor |
title | Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor |
title_full | Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor |
title_fullStr | Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor |
title_full_unstemmed | Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor |
title_short | Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor |
title_sort | clinical analysis of color doppler ultrasound diagnosis of senile cataract based on intelligent processor |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9068292/ https://www.ncbi.nlm.nih.gov/pubmed/35529272 http://dx.doi.org/10.1155/2022/1037439 |
work_keys_str_mv | AT chenyanyan clinicalanalysisofcolordopplerultrasounddiagnosisofsenilecataractbasedonintelligentprocessor AT xiaoxuebing clinicalanalysisofcolordopplerultrasounddiagnosisofsenilecataractbasedonintelligentprocessor AT wulan clinicalanalysisofcolordopplerultrasounddiagnosisofsenilecataractbasedonintelligentprocessor AT liuyang clinicalanalysisofcolordopplerultrasounddiagnosisofsenilecataractbasedonintelligentprocessor |