Cargando…

Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor

In order to improve the effect of on-the-spot diagnosis of senile cataract, this paper combines the intelligent processor to explore the application of color Doppler ultrasound in the clinical analysis of senile cataract. Moreover, this paper measures and calculates the diameter, perimeter, area, vo...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Yanyan, Xiao, Xuebing, Wu, Lan, Liu, Yang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9068292/
https://www.ncbi.nlm.nih.gov/pubmed/35529272
http://dx.doi.org/10.1155/2022/1037439
_version_ 1784700193816444928
author Chen, Yanyan
Xiao, Xuebing
Wu, Lan
Liu, Yang
author_facet Chen, Yanyan
Xiao, Xuebing
Wu, Lan
Liu, Yang
author_sort Chen, Yanyan
collection PubMed
description In order to improve the effect of on-the-spot diagnosis of senile cataract, this paper combines the intelligent processor to explore the application of color Doppler ultrasound in the clinical analysis of senile cataract. Moreover, this paper measures and calculates the diameter, perimeter, area, volume, or velocity of blood flow reflected by color Doppler ultrasound images. In addition, this paper adopts the measurement method provided by composite measurement to design the intelligent processor. Each measurement analysis package is defined as an independent class, and the data, properties, and methods are encapsulated in a class, which is beneficial to the modular design of the program and the overall management of the system. The experimental results verify that the intelligent processor proposed in this paper has a certain effect in the clinical analysis of color Doppler ultrasound diagnosis of senile cataract.
format Online
Article
Text
id pubmed-9068292
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-90682922022-05-05 Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor Chen, Yanyan Xiao, Xuebing Wu, Lan Liu, Yang Comput Math Methods Med Research Article In order to improve the effect of on-the-spot diagnosis of senile cataract, this paper combines the intelligent processor to explore the application of color Doppler ultrasound in the clinical analysis of senile cataract. Moreover, this paper measures and calculates the diameter, perimeter, area, volume, or velocity of blood flow reflected by color Doppler ultrasound images. In addition, this paper adopts the measurement method provided by composite measurement to design the intelligent processor. Each measurement analysis package is defined as an independent class, and the data, properties, and methods are encapsulated in a class, which is beneficial to the modular design of the program and the overall management of the system. The experimental results verify that the intelligent processor proposed in this paper has a certain effect in the clinical analysis of color Doppler ultrasound diagnosis of senile cataract. Hindawi 2022-04-27 /pmc/articles/PMC9068292/ /pubmed/35529272 http://dx.doi.org/10.1155/2022/1037439 Text en Copyright © 2022 Yanyan Chen et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chen, Yanyan
Xiao, Xuebing
Wu, Lan
Liu, Yang
Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor
title Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor
title_full Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor
title_fullStr Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor
title_full_unstemmed Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor
title_short Clinical Analysis of Color Doppler Ultrasound Diagnosis of Senile Cataract Based on Intelligent Processor
title_sort clinical analysis of color doppler ultrasound diagnosis of senile cataract based on intelligent processor
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9068292/
https://www.ncbi.nlm.nih.gov/pubmed/35529272
http://dx.doi.org/10.1155/2022/1037439
work_keys_str_mv AT chenyanyan clinicalanalysisofcolordopplerultrasounddiagnosisofsenilecataractbasedonintelligentprocessor
AT xiaoxuebing clinicalanalysisofcolordopplerultrasounddiagnosisofsenilecataractbasedonintelligentprocessor
AT wulan clinicalanalysisofcolordopplerultrasounddiagnosisofsenilecataractbasedonintelligentprocessor
AT liuyang clinicalanalysisofcolordopplerultrasounddiagnosisofsenilecataractbasedonintelligentprocessor