Cargando…

Bladder volume reproducibility after water consumption in patients with prostate cancer undergoing radiotherapy: A systematic review and meta-analysis

BACKGROUND: To minimize toxicity due to radiotherapy in patients with prostate cancer, high bladder volume reproducibility is essential. Water consumption is often used to increase bladder volume reproducibility, but the optimal amount of water required to be consumed remains unclear. We aimed to an...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Hsiao-Hsuan, Lin, Pei-Tzu, Kuo, Liang-Tseng, Lin, Kun-Sheng, Fang, Chiung-Chen, Chi, Ching-Chi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Chang Gung University 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9068550/
https://www.ncbi.nlm.nih.gov/pubmed/35300945
http://dx.doi.org/10.1016/j.bj.2020.11.004
Descripción
Sumario:BACKGROUND: To minimize toxicity due to radiotherapy in patients with prostate cancer, high bladder volume reproducibility is essential. Water consumption is often used to increase bladder volume reproducibility, but the optimal amount of water required to be consumed remains unclear. We aimed to analyzed the relationship between water consumption and bladder volume reproducibility in patients undergoing radiotherapy for prostate cancer. METHODS: We conducted a systematic review and meta-analysis of randomized controlled trials and cohort studies that assessed bladder volume change after water consumption in patients with prostate cancer undergoing radiotherapy. MEDLINE, Embase, and Cochrane Central Register of Controlled Trials were searched for relevant studies published from database inception up until July 4, 2020. The Newcastle–Ottawa Scale was used to evaluate the risk of bias in the included studies. The outcome was the mean difference (MD) of bladder volume after water consumption, evaluated through meta-analysis using a random-effects model. RESULTS: Ten cohort studies and one randomized controlled trial with a total of 417 patients were included. For 300–400 ml water consumption, the bladder volume MD between during treatment and at computer tomography-simulation (95% confidence interval [CI]) was −11.97 (−51.68 to 27.74), was −45.99 (−82.85 to −9.13) for 500–540 ml water consumption and −45.92 (−78.86 to −12.98) for water consumption until full-bladder sensation was reached. CONCLUSION: Consuming 300–400 ml of water potentially leads to the best bladder volume reproducibility; moreover, the higher the water consumption volume, the lower the bladder volume reproducibility.