Cargando…
Diagnostic accuracy of probe-based confocal laser endomicroscopy and tissue sampling by endoscopic retrograde cholangiopancreatography in indeterminate biliary strictures: a meta‑analysis
Probe-based confocal laser endomicroscopy (pCLE), also known as optical biopsy, is a new endoscopic technique that provides real-time magnification of 1000 × microscopic tissue information to diagnose indeterminate biliary strictures. Tissue sampling by endoscopic retrograde cholangiopancreatography...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9068817/ https://www.ncbi.nlm.nih.gov/pubmed/35508585 http://dx.doi.org/10.1038/s41598-022-11385-4 |
_version_ | 1784700301760004096 |
---|---|
author | Mi, Junjie Han, Xiaofang Wang, Rong Ma, Ruijun Zhao, Danyu |
author_facet | Mi, Junjie Han, Xiaofang Wang, Rong Ma, Ruijun Zhao, Danyu |
author_sort | Mi, Junjie |
collection | PubMed |
description | Probe-based confocal laser endomicroscopy (pCLE), also known as optical biopsy, is a new endoscopic technique that provides real-time magnification of 1000 × microscopic tissue information to diagnose indeterminate biliary strictures. Tissue sampling by endoscopic retrograde cholangiopancreatography (ERCP) is routinely performed to evaluate indeterminate biliary strictures. To evaluate the accuracy of pCLE and tissue sampling by ERCP in the diagnosis of indeterminate biliary strictures, 18 articles were included from 2008 to 2021 through Embase, PubMed, Web of Science, and Cochrane library databases. The summary estimates for the pCLE diagnosis of indeterminate biliary strictures were: sensitivity 0.88 (95% confidence interval (CI), 0.84–0.91); specificity 0.79 (95% CI 0.74–0.83); and Diagnostic Odds Ratio (DOR) 24.63 (95% CI 15.76–38.48). The summary estimates for tissue sampling by ERCP diagnosis for indeterminate biliary strictures were: sensitivity 0.54 (95% CI 0.49–0.59); specificity 0.96 (95% CI 0.94–0.98); and DOR 11.31 (95% CI 3.90–32.82). The area under the sROC curve of pCLE diagnosis of indeterminate biliary strictures is 0.90 higher than 0.65 of tissue sampling by ERCP. The pCLE is a better approach than tissue sampling by ERCP for the diagnosis of indeterminate biliary strictures by providing real-time microscopic images of the bile ducts. |
format | Online Article Text |
id | pubmed-9068817 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-90688172022-05-05 Diagnostic accuracy of probe-based confocal laser endomicroscopy and tissue sampling by endoscopic retrograde cholangiopancreatography in indeterminate biliary strictures: a meta‑analysis Mi, Junjie Han, Xiaofang Wang, Rong Ma, Ruijun Zhao, Danyu Sci Rep Article Probe-based confocal laser endomicroscopy (pCLE), also known as optical biopsy, is a new endoscopic technique that provides real-time magnification of 1000 × microscopic tissue information to diagnose indeterminate biliary strictures. Tissue sampling by endoscopic retrograde cholangiopancreatography (ERCP) is routinely performed to evaluate indeterminate biliary strictures. To evaluate the accuracy of pCLE and tissue sampling by ERCP in the diagnosis of indeterminate biliary strictures, 18 articles were included from 2008 to 2021 through Embase, PubMed, Web of Science, and Cochrane library databases. The summary estimates for the pCLE diagnosis of indeterminate biliary strictures were: sensitivity 0.88 (95% confidence interval (CI), 0.84–0.91); specificity 0.79 (95% CI 0.74–0.83); and Diagnostic Odds Ratio (DOR) 24.63 (95% CI 15.76–38.48). The summary estimates for tissue sampling by ERCP diagnosis for indeterminate biliary strictures were: sensitivity 0.54 (95% CI 0.49–0.59); specificity 0.96 (95% CI 0.94–0.98); and DOR 11.31 (95% CI 3.90–32.82). The area under the sROC curve of pCLE diagnosis of indeterminate biliary strictures is 0.90 higher than 0.65 of tissue sampling by ERCP. The pCLE is a better approach than tissue sampling by ERCP for the diagnosis of indeterminate biliary strictures by providing real-time microscopic images of the bile ducts. Nature Publishing Group UK 2022-05-04 /pmc/articles/PMC9068817/ /pubmed/35508585 http://dx.doi.org/10.1038/s41598-022-11385-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Mi, Junjie Han, Xiaofang Wang, Rong Ma, Ruijun Zhao, Danyu Diagnostic accuracy of probe-based confocal laser endomicroscopy and tissue sampling by endoscopic retrograde cholangiopancreatography in indeterminate biliary strictures: a meta‑analysis |
title | Diagnostic accuracy of probe-based confocal laser endomicroscopy and tissue sampling by endoscopic retrograde cholangiopancreatography in indeterminate biliary strictures: a meta‑analysis |
title_full | Diagnostic accuracy of probe-based confocal laser endomicroscopy and tissue sampling by endoscopic retrograde cholangiopancreatography in indeterminate biliary strictures: a meta‑analysis |
title_fullStr | Diagnostic accuracy of probe-based confocal laser endomicroscopy and tissue sampling by endoscopic retrograde cholangiopancreatography in indeterminate biliary strictures: a meta‑analysis |
title_full_unstemmed | Diagnostic accuracy of probe-based confocal laser endomicroscopy and tissue sampling by endoscopic retrograde cholangiopancreatography in indeterminate biliary strictures: a meta‑analysis |
title_short | Diagnostic accuracy of probe-based confocal laser endomicroscopy and tissue sampling by endoscopic retrograde cholangiopancreatography in indeterminate biliary strictures: a meta‑analysis |
title_sort | diagnostic accuracy of probe-based confocal laser endomicroscopy and tissue sampling by endoscopic retrograde cholangiopancreatography in indeterminate biliary strictures: a meta‑analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9068817/ https://www.ncbi.nlm.nih.gov/pubmed/35508585 http://dx.doi.org/10.1038/s41598-022-11385-4 |
work_keys_str_mv | AT mijunjie diagnosticaccuracyofprobebasedconfocallaserendomicroscopyandtissuesamplingbyendoscopicretrogradecholangiopancreatographyinindeterminatebiliarystricturesametaanalysis AT hanxiaofang diagnosticaccuracyofprobebasedconfocallaserendomicroscopyandtissuesamplingbyendoscopicretrogradecholangiopancreatographyinindeterminatebiliarystricturesametaanalysis AT wangrong diagnosticaccuracyofprobebasedconfocallaserendomicroscopyandtissuesamplingbyendoscopicretrogradecholangiopancreatographyinindeterminatebiliarystricturesametaanalysis AT maruijun diagnosticaccuracyofprobebasedconfocallaserendomicroscopyandtissuesamplingbyendoscopicretrogradecholangiopancreatographyinindeterminatebiliarystricturesametaanalysis AT zhaodanyu diagnosticaccuracyofprobebasedconfocallaserendomicroscopyandtissuesamplingbyendoscopicretrogradecholangiopancreatographyinindeterminatebiliarystricturesametaanalysis |