Cargando…

Heavy Silicone Oil as an Endotamponade in Recurrent or Complicated Retinal Detachment and Macular Hole

OBJECTIVES: To evaluate the efficacy and safety of heavy silicone oil as an endotamponade in patients with recurrent or complicated retinal detachment and macular hole. MATERIALS AND METHODS: Nineteen eyes of 19 patients who underwent heavy silicone oil endotamponade for different indications were i...

Descripción completa

Detalles Bibliográficos
Autores principales: Kurt, Rengin Aslıhan, Kapran, Ziya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9069085/
https://www.ncbi.nlm.nih.gov/pubmed/35481733
http://dx.doi.org/10.4274/tjo.galenos.2021.83648
_version_ 1784700352400982016
author Kurt, Rengin Aslıhan
Kapran, Ziya
author_facet Kurt, Rengin Aslıhan
Kapran, Ziya
author_sort Kurt, Rengin Aslıhan
collection PubMed
description OBJECTIVES: To evaluate the efficacy and safety of heavy silicone oil as an endotamponade in patients with recurrent or complicated retinal detachment and macular hole. MATERIALS AND METHODS: Nineteen eyes of 19 patients who underwent heavy silicone oil endotamponade for different indications were included in the study and evaluated by retrospective chart review. At each visit, patients underwent detailed ophthalmological examination and anatomical and functional outcomes, silicone oil emulsification, intraocular inflammation, presence of proliferative vitreoretinopathy, preoperative and postoperative visual acuity, and postoperative complications were recorded. RESULTS: The study included 19 eyes of 19 consecutive patients: 13 women (68.4%) and 6 men (31.6%). The patients’ median age was 60 years (interquartile range [IQR]: 44-70 years) and the median follow-up time was 19 months (IQR: 9-31 months). Indications for heavy silicone oil endotamponade were recurrent retinal detachment in 11 eyes (57.8%), inferior retinal detachment in 5 eyes (26.3%), inferior rhegmatogenous retinal detachment, recurrent macular hole in 2 patients (10.5%), and macular hole in 1 patient (5.2%). Median best corrected visual acuity was 2 logMAR (IQR: 1-2.6) preoperatively and 0.99 logMAR (IQR: 0.4-2) postoperatively (p<0.001). Postoperative anatomical success was achieved in all patients. Densiron 68 was used for endotamponade in 14 patients (73.7%), Densiron XTRA in 3 patients (15.8%), and AlaHeavy 1.07 in 2 patients. Heavy silicone oil emulsification was observed in only 3 patients (15.8%). CONCLUSION: Although heavy silicone oil has limitations as an endotamponade, such as intraocular pressure increase, emulsification, intraocular inflammation, and the risk of complications during removal, it is a safe and effective alternative in eyes requiring inferior retinal tamponade for indications like proliferative vitreoretinopathy and recurrent macular holes.
format Online
Article
Text
id pubmed-9069085
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-90690852022-05-13 Heavy Silicone Oil as an Endotamponade in Recurrent or Complicated Retinal Detachment and Macular Hole Kurt, Rengin Aslıhan Kapran, Ziya Turk J Ophthalmol Original Article OBJECTIVES: To evaluate the efficacy and safety of heavy silicone oil as an endotamponade in patients with recurrent or complicated retinal detachment and macular hole. MATERIALS AND METHODS: Nineteen eyes of 19 patients who underwent heavy silicone oil endotamponade for different indications were included in the study and evaluated by retrospective chart review. At each visit, patients underwent detailed ophthalmological examination and anatomical and functional outcomes, silicone oil emulsification, intraocular inflammation, presence of proliferative vitreoretinopathy, preoperative and postoperative visual acuity, and postoperative complications were recorded. RESULTS: The study included 19 eyes of 19 consecutive patients: 13 women (68.4%) and 6 men (31.6%). The patients’ median age was 60 years (interquartile range [IQR]: 44-70 years) and the median follow-up time was 19 months (IQR: 9-31 months). Indications for heavy silicone oil endotamponade were recurrent retinal detachment in 11 eyes (57.8%), inferior retinal detachment in 5 eyes (26.3%), inferior rhegmatogenous retinal detachment, recurrent macular hole in 2 patients (10.5%), and macular hole in 1 patient (5.2%). Median best corrected visual acuity was 2 logMAR (IQR: 1-2.6) preoperatively and 0.99 logMAR (IQR: 0.4-2) postoperatively (p<0.001). Postoperative anatomical success was achieved in all patients. Densiron 68 was used for endotamponade in 14 patients (73.7%), Densiron XTRA in 3 patients (15.8%), and AlaHeavy 1.07 in 2 patients. Heavy silicone oil emulsification was observed in only 3 patients (15.8%). CONCLUSION: Although heavy silicone oil has limitations as an endotamponade, such as intraocular pressure increase, emulsification, intraocular inflammation, and the risk of complications during removal, it is a safe and effective alternative in eyes requiring inferior retinal tamponade for indications like proliferative vitreoretinopathy and recurrent macular holes. Galenos Publishing 2022-04 2022-04-28 /pmc/articles/PMC9069085/ /pubmed/35481733 http://dx.doi.org/10.4274/tjo.galenos.2021.83648 Text en © Copyright 2022 by Turkish Ophthalmological Association | Turkish Journal of Ophthalmology, published by Galenos Publishing House. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kurt, Rengin Aslıhan
Kapran, Ziya
Heavy Silicone Oil as an Endotamponade in Recurrent or Complicated Retinal Detachment and Macular Hole
title Heavy Silicone Oil as an Endotamponade in Recurrent or Complicated Retinal Detachment and Macular Hole
title_full Heavy Silicone Oil as an Endotamponade in Recurrent or Complicated Retinal Detachment and Macular Hole
title_fullStr Heavy Silicone Oil as an Endotamponade in Recurrent or Complicated Retinal Detachment and Macular Hole
title_full_unstemmed Heavy Silicone Oil as an Endotamponade in Recurrent or Complicated Retinal Detachment and Macular Hole
title_short Heavy Silicone Oil as an Endotamponade in Recurrent or Complicated Retinal Detachment and Macular Hole
title_sort heavy silicone oil as an endotamponade in recurrent or complicated retinal detachment and macular hole
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9069085/
https://www.ncbi.nlm.nih.gov/pubmed/35481733
http://dx.doi.org/10.4274/tjo.galenos.2021.83648
work_keys_str_mv AT kurtrenginaslıhan heavysiliconeoilasanendotamponadeinrecurrentorcomplicatedretinaldetachmentandmacularhole
AT kapranziya heavysiliconeoilasanendotamponadeinrecurrentorcomplicatedretinaldetachmentandmacularhole