Modified implantation of a Bolton Relay branch arch device into the ascending aorta close to a mechanical aortic valve
An aortic arch stent graft is usually contraindicated with a mechanical aortic valve. However, a modified stent graft plus the use of an externalized transapical guidewire technique allowed a safe implantation close to a mechanical aortic valve.
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9070509/ https://www.ncbi.nlm.nih.gov/pubmed/35142358 http://dx.doi.org/10.1093/icvts/ivac017 |
_version_ | 1784700655787573248 |
---|---|
author | Milnerowicz, Artur Jędrzejczak, Tomasz Rynio, Paweł Kazimierczak, Arkadiusz |
author_facet | Milnerowicz, Artur Jędrzejczak, Tomasz Rynio, Paweł Kazimierczak, Arkadiusz |
author_sort | Milnerowicz, Artur |
collection | PubMed |
description | An aortic arch stent graft is usually contraindicated with a mechanical aortic valve. However, a modified stent graft plus the use of an externalized transapical guidewire technique allowed a safe implantation close to a mechanical aortic valve. |
format | Online Article Text |
id | pubmed-9070509 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-90705092022-05-06 Modified implantation of a Bolton Relay branch arch device into the ascending aorta close to a mechanical aortic valve Milnerowicz, Artur Jędrzejczak, Tomasz Rynio, Paweł Kazimierczak, Arkadiusz Interact Cardiovasc Thorac Surg Case Reports An aortic arch stent graft is usually contraindicated with a mechanical aortic valve. However, a modified stent graft plus the use of an externalized transapical guidewire technique allowed a safe implantation close to a mechanical aortic valve. Oxford University Press 2022-02-10 /pmc/articles/PMC9070509/ /pubmed/35142358 http://dx.doi.org/10.1093/icvts/ivac017 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Reports Milnerowicz, Artur Jędrzejczak, Tomasz Rynio, Paweł Kazimierczak, Arkadiusz Modified implantation of a Bolton Relay branch arch device into the ascending aorta close to a mechanical aortic valve |
title | Modified implantation of a Bolton Relay branch arch device into the ascending aorta close to a mechanical aortic valve |
title_full | Modified implantation of a Bolton Relay branch arch device into the ascending aorta close to a mechanical aortic valve |
title_fullStr | Modified implantation of a Bolton Relay branch arch device into the ascending aorta close to a mechanical aortic valve |
title_full_unstemmed | Modified implantation of a Bolton Relay branch arch device into the ascending aorta close to a mechanical aortic valve |
title_short | Modified implantation of a Bolton Relay branch arch device into the ascending aorta close to a mechanical aortic valve |
title_sort | modified implantation of a bolton relay branch arch device into the ascending aorta close to a mechanical aortic valve |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9070509/ https://www.ncbi.nlm.nih.gov/pubmed/35142358 http://dx.doi.org/10.1093/icvts/ivac017 |
work_keys_str_mv | AT milnerowiczartur modifiedimplantationofaboltonrelaybrancharchdeviceintotheascendingaortaclosetoamechanicalaorticvalve AT jedrzejczaktomasz modifiedimplantationofaboltonrelaybrancharchdeviceintotheascendingaortaclosetoamechanicalaorticvalve AT ryniopaweł modifiedimplantationofaboltonrelaybrancharchdeviceintotheascendingaortaclosetoamechanicalaorticvalve AT kazimierczakarkadiusz modifiedimplantationofaboltonrelaybrancharchdeviceintotheascendingaortaclosetoamechanicalaorticvalve |