Cargando…

The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection

The current work describes the use of a steel acupuncture needle as an electrode substrate in order to construct an Ni(6)MnO(8) nanoflake layer-modified microneedle sensor for highly sensitive ascorbic acid detection. For the purpose of constructing the functionalized acupuncture needle, first, a ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Jia, Hongliang, Zhao, Jianwei, Qin, Lirong, Zhao, Min, Liu, Gang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9070663/
https://www.ncbi.nlm.nih.gov/pubmed/35528607
http://dx.doi.org/10.1039/c9ra03850g
_version_ 1784700690230149120
author Jia, Hongliang
Zhao, Jianwei
Qin, Lirong
Zhao, Min
Liu, Gang
author_facet Jia, Hongliang
Zhao, Jianwei
Qin, Lirong
Zhao, Min
Liu, Gang
author_sort Jia, Hongliang
collection PubMed
description The current work describes the use of a steel acupuncture needle as an electrode substrate in order to construct an Ni(6)MnO(8) nanoflake layer-modified microneedle sensor for highly sensitive ascorbic acid detection. For the purpose of constructing the functionalized acupuncture needle, first, a carbon film was layered on the needle surface as the seed layer. Subsequently, a straightforward hydrothermal reaction-calcination process was employed for the growth of Ni(6)MnO(8) nanoflakes on the needle to function as a sensing interface. Electrochemical investigations illustrated the fact that the Ni(6)MnO(8) nanoflake-altered acupuncture needle electrode manifested outstanding efficiency toward the amperometric identification of ascorbic acid. In addition, the electrode manifested elevated sensitivity of 3106 μA mM(−1) cm(−2), detection limit of 0.1 μM, and a broad linear range between 1.0 μM and 2.0 mM. As demonstrated by the results, the Ni(6)MnO(8) nanoflake-modified acupuncture needle constitutes a potentially fresh platform to construct non-enzymatic ascorbic acid sensors.
format Online
Article
Text
id pubmed-9070663
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90706632022-05-05 The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection Jia, Hongliang Zhao, Jianwei Qin, Lirong Zhao, Min Liu, Gang RSC Adv Chemistry The current work describes the use of a steel acupuncture needle as an electrode substrate in order to construct an Ni(6)MnO(8) nanoflake layer-modified microneedle sensor for highly sensitive ascorbic acid detection. For the purpose of constructing the functionalized acupuncture needle, first, a carbon film was layered on the needle surface as the seed layer. Subsequently, a straightforward hydrothermal reaction-calcination process was employed for the growth of Ni(6)MnO(8) nanoflakes on the needle to function as a sensing interface. Electrochemical investigations illustrated the fact that the Ni(6)MnO(8) nanoflake-altered acupuncture needle electrode manifested outstanding efficiency toward the amperometric identification of ascorbic acid. In addition, the electrode manifested elevated sensitivity of 3106 μA mM(−1) cm(−2), detection limit of 0.1 μM, and a broad linear range between 1.0 μM and 2.0 mM. As demonstrated by the results, the Ni(6)MnO(8) nanoflake-modified acupuncture needle constitutes a potentially fresh platform to construct non-enzymatic ascorbic acid sensors. The Royal Society of Chemistry 2019-08-28 /pmc/articles/PMC9070663/ /pubmed/35528607 http://dx.doi.org/10.1039/c9ra03850g Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Jia, Hongliang
Zhao, Jianwei
Qin, Lirong
Zhao, Min
Liu, Gang
The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection
title The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection
title_full The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection
title_fullStr The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection
title_full_unstemmed The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection
title_short The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection
title_sort fabrication of an ni(6)mno(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9070663/
https://www.ncbi.nlm.nih.gov/pubmed/35528607
http://dx.doi.org/10.1039/c9ra03850g
work_keys_str_mv AT jiahongliang thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection
AT zhaojianwei thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection
AT qinlirong thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection
AT zhaomin thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection
AT liugang thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection
AT jiahongliang fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection
AT zhaojianwei fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection
AT qinlirong fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection
AT zhaomin fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection
AT liugang fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection