Cargando…
The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection
The current work describes the use of a steel acupuncture needle as an electrode substrate in order to construct an Ni(6)MnO(8) nanoflake layer-modified microneedle sensor for highly sensitive ascorbic acid detection. For the purpose of constructing the functionalized acupuncture needle, first, a ca...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9070663/ https://www.ncbi.nlm.nih.gov/pubmed/35528607 http://dx.doi.org/10.1039/c9ra03850g |
_version_ | 1784700690230149120 |
---|---|
author | Jia, Hongliang Zhao, Jianwei Qin, Lirong Zhao, Min Liu, Gang |
author_facet | Jia, Hongliang Zhao, Jianwei Qin, Lirong Zhao, Min Liu, Gang |
author_sort | Jia, Hongliang |
collection | PubMed |
description | The current work describes the use of a steel acupuncture needle as an electrode substrate in order to construct an Ni(6)MnO(8) nanoflake layer-modified microneedle sensor for highly sensitive ascorbic acid detection. For the purpose of constructing the functionalized acupuncture needle, first, a carbon film was layered on the needle surface as the seed layer. Subsequently, a straightforward hydrothermal reaction-calcination process was employed for the growth of Ni(6)MnO(8) nanoflakes on the needle to function as a sensing interface. Electrochemical investigations illustrated the fact that the Ni(6)MnO(8) nanoflake-altered acupuncture needle electrode manifested outstanding efficiency toward the amperometric identification of ascorbic acid. In addition, the electrode manifested elevated sensitivity of 3106 μA mM(−1) cm(−2), detection limit of 0.1 μM, and a broad linear range between 1.0 μM and 2.0 mM. As demonstrated by the results, the Ni(6)MnO(8) nanoflake-modified acupuncture needle constitutes a potentially fresh platform to construct non-enzymatic ascorbic acid sensors. |
format | Online Article Text |
id | pubmed-9070663 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-90706632022-05-05 The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection Jia, Hongliang Zhao, Jianwei Qin, Lirong Zhao, Min Liu, Gang RSC Adv Chemistry The current work describes the use of a steel acupuncture needle as an electrode substrate in order to construct an Ni(6)MnO(8) nanoflake layer-modified microneedle sensor for highly sensitive ascorbic acid detection. For the purpose of constructing the functionalized acupuncture needle, first, a carbon film was layered on the needle surface as the seed layer. Subsequently, a straightforward hydrothermal reaction-calcination process was employed for the growth of Ni(6)MnO(8) nanoflakes on the needle to function as a sensing interface. Electrochemical investigations illustrated the fact that the Ni(6)MnO(8) nanoflake-altered acupuncture needle electrode manifested outstanding efficiency toward the amperometric identification of ascorbic acid. In addition, the electrode manifested elevated sensitivity of 3106 μA mM(−1) cm(−2), detection limit of 0.1 μM, and a broad linear range between 1.0 μM and 2.0 mM. As demonstrated by the results, the Ni(6)MnO(8) nanoflake-modified acupuncture needle constitutes a potentially fresh platform to construct non-enzymatic ascorbic acid sensors. The Royal Society of Chemistry 2019-08-28 /pmc/articles/PMC9070663/ /pubmed/35528607 http://dx.doi.org/10.1039/c9ra03850g Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Jia, Hongliang Zhao, Jianwei Qin, Lirong Zhao, Min Liu, Gang The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection |
title | The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection |
title_full | The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection |
title_fullStr | The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection |
title_full_unstemmed | The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection |
title_short | The fabrication of an Ni(6)MnO(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection |
title_sort | fabrication of an ni(6)mno(8) nanoflake-modified acupuncture needle electrode for highly sensitive ascorbic acid detection |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9070663/ https://www.ncbi.nlm.nih.gov/pubmed/35528607 http://dx.doi.org/10.1039/c9ra03850g |
work_keys_str_mv | AT jiahongliang thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection AT zhaojianwei thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection AT qinlirong thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection AT zhaomin thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection AT liugang thefabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection AT jiahongliang fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection AT zhaojianwei fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection AT qinlirong fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection AT zhaomin fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection AT liugang fabricationofanni6mno8nanoflakemodifiedacupunctureneedleelectrodeforhighlysensitiveascorbicaciddetection |