Cargando…

Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens

AIM: To evaluate visual results and patient-perceived outcomes in patients with ocular pathologies implanted with a new extended depth-of-focus intraocular lens (IOL). METHODS: Patients with ocular pathology undergoing cataract surgery and bilaterally implanted with Vivity® IOLs were evaluated three...

Descripción completa

Detalles Bibliográficos
Autores principales: Rementería-Capelo, Laureano A., Lorente, Pilar, Carrillo, Virginia, Sánchez-Pina, José M., Ruiz-Alcocer, Javier, Contreras, Inés
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9071907/
https://www.ncbi.nlm.nih.gov/pubmed/35529167
http://dx.doi.org/10.1155/2022/4659309
_version_ 1784700933618270208
author Rementería-Capelo, Laureano A.
Lorente, Pilar
Carrillo, Virginia
Sánchez-Pina, José M.
Ruiz-Alcocer, Javier
Contreras, Inés
author_facet Rementería-Capelo, Laureano A.
Lorente, Pilar
Carrillo, Virginia
Sánchez-Pina, José M.
Ruiz-Alcocer, Javier
Contreras, Inés
author_sort Rementería-Capelo, Laureano A.
collection PubMed
description AIM: To evaluate visual results and patient-perceived outcomes in patients with ocular pathologies implanted with a new extended depth-of-focus intraocular lens (IOL). METHODS: Patients with ocular pathology undergoing cataract surgery and bilaterally implanted with Vivity® IOLs were evaluated three months after surgery. The control group included patients with no ocular pathologies. Binocular defocus curves, corrected and uncorrected mono- and binocular distance visual acuity (DVA), and binocular contrast sensitivity were measured. Patients completed the Catquest-9SF questionnaire and reported on dysphotopsia and their need for spectacle-correction. RESULTS: Twenty-five patients were included in each group. Monocular uncorrected DVA was better in the control group (−0.01 ± 0.07) compared with the study group (0.03 ± 0.08), p=0.027. There were no other statistically significant differences in DVA, with an uncorrected binocular acuity of −0.06 ± 0.06 for the control group and −0.05 ± 0.06 for the study group. Binocular defocus curves were similar for both groups and there were no differences in contrast sensitivity values. Pooling the refractive results, 96% of eyes were within ±0.50 D of target refraction. Seventy percent of patients in the control group reported no halos, compared with 40% in the study group, p=0.047. In both groups, 40% of patients reported being completely spectacle-independent, with the other 60% requiring glasses for near vision always or often. All patients reported being fairly or very satisfied with their vision. CONCLUSION: Initial results of visual function after Vivity implantation in patients with ocular pathologies are encouraging, with high patient satisfaction and few difficulties for daily activities.
format Online
Article
Text
id pubmed-9071907
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-90719072022-05-06 Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens Rementería-Capelo, Laureano A. Lorente, Pilar Carrillo, Virginia Sánchez-Pina, José M. Ruiz-Alcocer, Javier Contreras, Inés J Ophthalmol Research Article AIM: To evaluate visual results and patient-perceived outcomes in patients with ocular pathologies implanted with a new extended depth-of-focus intraocular lens (IOL). METHODS: Patients with ocular pathology undergoing cataract surgery and bilaterally implanted with Vivity® IOLs were evaluated three months after surgery. The control group included patients with no ocular pathologies. Binocular defocus curves, corrected and uncorrected mono- and binocular distance visual acuity (DVA), and binocular contrast sensitivity were measured. Patients completed the Catquest-9SF questionnaire and reported on dysphotopsia and their need for spectacle-correction. RESULTS: Twenty-five patients were included in each group. Monocular uncorrected DVA was better in the control group (−0.01 ± 0.07) compared with the study group (0.03 ± 0.08), p=0.027. There were no other statistically significant differences in DVA, with an uncorrected binocular acuity of −0.06 ± 0.06 for the control group and −0.05 ± 0.06 for the study group. Binocular defocus curves were similar for both groups and there were no differences in contrast sensitivity values. Pooling the refractive results, 96% of eyes were within ±0.50 D of target refraction. Seventy percent of patients in the control group reported no halos, compared with 40% in the study group, p=0.047. In both groups, 40% of patients reported being completely spectacle-independent, with the other 60% requiring glasses for near vision always or often. All patients reported being fairly or very satisfied with their vision. CONCLUSION: Initial results of visual function after Vivity implantation in patients with ocular pathologies are encouraging, with high patient satisfaction and few difficulties for daily activities. Hindawi 2022-04-28 /pmc/articles/PMC9071907/ /pubmed/35529167 http://dx.doi.org/10.1155/2022/4659309 Text en Copyright © 2022 Laureano A. Rementería-Capelo et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Rementería-Capelo, Laureano A.
Lorente, Pilar
Carrillo, Virginia
Sánchez-Pina, José M.
Ruiz-Alcocer, Javier
Contreras, Inés
Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens
title Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens
title_full Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens
title_fullStr Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens
title_full_unstemmed Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens
title_short Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens
title_sort patient satisfaction and visual performance in patients with ocular pathology after bilateral implantation of a new extended depth of focus intraocular lens
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9071907/
https://www.ncbi.nlm.nih.gov/pubmed/35529167
http://dx.doi.org/10.1155/2022/4659309
work_keys_str_mv AT rementeriacapelolaureanoa patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens
AT lorentepilar patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens
AT carrillovirginia patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens
AT sanchezpinajosem patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens
AT ruizalcocerjavier patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens
AT contrerasines patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens