AIM: To evaluate visual results and patient-perceived outcomes in patients with ocular pathologies implanted with a new extended depth-of-focus intraocular lens (IOL). METHODS: Patients with ocular pathology undergoing cataract surgery and bilaterally implanted with Vivity® IOLs were evaluated three...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9071907/ https://www.ncbi.nlm.nih.gov/pubmed/35529167 http://dx.doi.org/10.1155/2022/4659309 |
_version_ | 1784700933618270208 |
---|---|
author | Rementería-Capelo, Laureano A. Lorente, Pilar Carrillo, Virginia Sánchez-Pina, José M. Ruiz-Alcocer, Javier Contreras, Inés |
author_facet | Rementería-Capelo, Laureano A. Lorente, Pilar Carrillo, Virginia Sánchez-Pina, José M. Ruiz-Alcocer, Javier Contreras, Inés |
author_sort | Rementería-Capelo, Laureano A. |
collection | PubMed |
description | AIM: To evaluate visual results and patient-perceived outcomes in patients with ocular pathologies implanted with a new extended depth-of-focus intraocular lens (IOL). METHODS: Patients with ocular pathology undergoing cataract surgery and bilaterally implanted with Vivity® IOLs were evaluated three months after surgery. The control group included patients with no ocular pathologies. Binocular defocus curves, corrected and uncorrected mono- and binocular distance visual acuity (DVA), and binocular contrast sensitivity were measured. Patients completed the Catquest-9SF questionnaire and reported on dysphotopsia and their need for spectacle-correction. RESULTS: Twenty-five patients were included in each group. Monocular uncorrected DVA was better in the control group (−0.01 ± 0.07) compared with the study group (0.03 ± 0.08), p=0.027. There were no other statistically significant differences in DVA, with an uncorrected binocular acuity of −0.06 ± 0.06 for the control group and −0.05 ± 0.06 for the study group. Binocular defocus curves were similar for both groups and there were no differences in contrast sensitivity values. Pooling the refractive results, 96% of eyes were within ±0.50 D of target refraction. Seventy percent of patients in the control group reported no halos, compared with 40% in the study group, p=0.047. In both groups, 40% of patients reported being completely spectacle-independent, with the other 60% requiring glasses for near vision always or often. All patients reported being fairly or very satisfied with their vision. CONCLUSION: Initial results of visual function after Vivity implantation in patients with ocular pathologies are encouraging, with high patient satisfaction and few difficulties for daily activities. |
format | Online Article Text |
id | pubmed-9071907 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-90719072022-05-06 Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens Rementería-Capelo, Laureano A. Lorente, Pilar Carrillo, Virginia Sánchez-Pina, José M. Ruiz-Alcocer, Javier Contreras, Inés J Ophthalmol Research Article AIM: To evaluate visual results and patient-perceived outcomes in patients with ocular pathologies implanted with a new extended depth-of-focus intraocular lens (IOL). METHODS: Patients with ocular pathology undergoing cataract surgery and bilaterally implanted with Vivity® IOLs were evaluated three months after surgery. The control group included patients with no ocular pathologies. Binocular defocus curves, corrected and uncorrected mono- and binocular distance visual acuity (DVA), and binocular contrast sensitivity were measured. Patients completed the Catquest-9SF questionnaire and reported on dysphotopsia and their need for spectacle-correction. RESULTS: Twenty-five patients were included in each group. Monocular uncorrected DVA was better in the control group (−0.01 ± 0.07) compared with the study group (0.03 ± 0.08), p=0.027. There were no other statistically significant differences in DVA, with an uncorrected binocular acuity of −0.06 ± 0.06 for the control group and −0.05 ± 0.06 for the study group. Binocular defocus curves were similar for both groups and there were no differences in contrast sensitivity values. Pooling the refractive results, 96% of eyes were within ±0.50 D of target refraction. Seventy percent of patients in the control group reported no halos, compared with 40% in the study group, p=0.047. In both groups, 40% of patients reported being completely spectacle-independent, with the other 60% requiring glasses for near vision always or often. All patients reported being fairly or very satisfied with their vision. CONCLUSION: Initial results of visual function after Vivity implantation in patients with ocular pathologies are encouraging, with high patient satisfaction and few difficulties for daily activities. Hindawi 2022-04-28 /pmc/articles/PMC9071907/ /pubmed/35529167 http://dx.doi.org/10.1155/2022/4659309 Text en Copyright © 2022 Laureano A. Rementería-Capelo et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Rementería-Capelo, Laureano A. Lorente, Pilar Carrillo, Virginia Sánchez-Pina, José M. Ruiz-Alcocer, Javier Contreras, Inés Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens |
title | Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens |
title_full | Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens |
title_fullStr | Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens |
title_full_unstemmed | Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens |
title_short | Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens |
title_sort | patient satisfaction and visual performance in patients with ocular pathology after bilateral implantation of a new extended depth of focus intraocular lens |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9071907/ https://www.ncbi.nlm.nih.gov/pubmed/35529167 http://dx.doi.org/10.1155/2022/4659309 |
work_keys_str_mv | AT rementeriacapelolaureanoa patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens AT lorentepilar patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens AT carrillovirginia patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens AT sanchezpinajosem patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens AT ruizalcocerjavier patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens AT contrerasines patientsatisfactionandvisualperformanceinpatientswithocularpathologyafterbilateralimplantationofanewextendeddepthoffocusintraocularlens |