Cargando…
Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials
OBJECTIVES: The aim was to investigate color, gloss, or roughness of splint materials after storage in liquids and toothbrush simulation. MATERIALS AND METHODS: A total of 58 × 8 (n = 10 per material and group) specimens were fabricated (hand-cast, thermoforming, CAD/CAM-milled, 3D-printed materials...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9072518/ https://www.ncbi.nlm.nih.gov/pubmed/35119536 http://dx.doi.org/10.1007/s00784-022-04391-3 |
_version_ | 1784701079887282176 |
---|---|
author | Hickl, Verena Strasser, Thomas Schmid, Alois Rosentritt, Martin |
author_facet | Hickl, Verena Strasser, Thomas Schmid, Alois Rosentritt, Martin |
author_sort | Hickl, Verena |
collection | PubMed |
description | OBJECTIVES: The aim was to investigate color, gloss, or roughness of splint materials after storage in liquids and toothbrush simulation. MATERIALS AND METHODS: A total of 58 × 8 (n = 10 per material and group) specimens were fabricated (hand-cast, thermoforming, CAD/CAM-milled, 3D-printed materials); stored in air, water, coffee, red wine, and cleaning tablets; and investigated after fabrication, 24 h, two-, and four-week storage or toothbrushing. Color values (L*, a*, b*; ISO 11664–4:2008; CM–3500d, Konica-Minolta), gloss (ISO 2813:2014), and roughness values were determined (3D laser-scanning-microscope, KJ 3D, Keyence) before and after simulation or storage. Statistics: Levene-test, one-way ANOVA, Bonferroni post hoc test, between-subjects effects, Pearson correlation (α = 0.05). RESULTS: Color, gloss, and roughness altered due to contact with staining solutions/toothbrush simulation. Highest impact on color, gloss, and roughness presented the material followed by storage time (ΔE material (η2 = 0.239/p < 0.001), storage time (η2 = 0.179/p < 0.001); gloss (η2 = 0.751/p < 0.001) (η2 = 0.401/p < 0.001); Ra/Rz (η2 ≥ 0.801/p < 0.001) (η2 ≥ 0.416/p < 0.001)). Correlations were found between Rz and Ra (Pearson 0.887/p ≤ 0.001) or Rz and ΔE (0.517/p ≤ 0.001) or Ra and ΔE (0.460/p ≤ 0.001). CONCLUSIONS: Storage and toothbrushing were accompanied by a change in color, gloss, and roughness. Almost all materials showed visible discoloration after 4 weeks of storage. Gloss values decreased as storage time increased. The initial roughness and polishability were better with harder materials. Clinical relevance. Milled and 3D printed splints show good color, gloss, and roughness resistance after 4-week storage or toothbrush application. |
format | Online Article Text |
id | pubmed-9072518 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-90725182022-05-07 Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials Hickl, Verena Strasser, Thomas Schmid, Alois Rosentritt, Martin Clin Oral Investig Original Article OBJECTIVES: The aim was to investigate color, gloss, or roughness of splint materials after storage in liquids and toothbrush simulation. MATERIALS AND METHODS: A total of 58 × 8 (n = 10 per material and group) specimens were fabricated (hand-cast, thermoforming, CAD/CAM-milled, 3D-printed materials); stored in air, water, coffee, red wine, and cleaning tablets; and investigated after fabrication, 24 h, two-, and four-week storage or toothbrushing. Color values (L*, a*, b*; ISO 11664–4:2008; CM–3500d, Konica-Minolta), gloss (ISO 2813:2014), and roughness values were determined (3D laser-scanning-microscope, KJ 3D, Keyence) before and after simulation or storage. Statistics: Levene-test, one-way ANOVA, Bonferroni post hoc test, between-subjects effects, Pearson correlation (α = 0.05). RESULTS: Color, gloss, and roughness altered due to contact with staining solutions/toothbrush simulation. Highest impact on color, gloss, and roughness presented the material followed by storage time (ΔE material (η2 = 0.239/p < 0.001), storage time (η2 = 0.179/p < 0.001); gloss (η2 = 0.751/p < 0.001) (η2 = 0.401/p < 0.001); Ra/Rz (η2 ≥ 0.801/p < 0.001) (η2 ≥ 0.416/p < 0.001)). Correlations were found between Rz and Ra (Pearson 0.887/p ≤ 0.001) or Rz and ΔE (0.517/p ≤ 0.001) or Ra and ΔE (0.460/p ≤ 0.001). CONCLUSIONS: Storage and toothbrushing were accompanied by a change in color, gloss, and roughness. Almost all materials showed visible discoloration after 4 weeks of storage. Gloss values decreased as storage time increased. The initial roughness and polishability were better with harder materials. Clinical relevance. Milled and 3D printed splints show good color, gloss, and roughness resistance after 4-week storage or toothbrush application. Springer Berlin Heidelberg 2022-02-04 2022 /pmc/articles/PMC9072518/ /pubmed/35119536 http://dx.doi.org/10.1007/s00784-022-04391-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Hickl, Verena Strasser, Thomas Schmid, Alois Rosentritt, Martin Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials |
title | Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials |
title_full | Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials |
title_fullStr | Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials |
title_full_unstemmed | Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials |
title_short | Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials |
title_sort | effects of storage and toothbrush simulation on color, gloss, and roughness of cad/cam, hand-cast, thermoforming, and 3d-printed splint materials |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9072518/ https://www.ncbi.nlm.nih.gov/pubmed/35119536 http://dx.doi.org/10.1007/s00784-022-04391-3 |
work_keys_str_mv | AT hicklverena effectsofstorageandtoothbrushsimulationoncolorglossandroughnessofcadcamhandcastthermoformingand3dprintedsplintmaterials AT strasserthomas effectsofstorageandtoothbrushsimulationoncolorglossandroughnessofcadcamhandcastthermoformingand3dprintedsplintmaterials AT schmidalois effectsofstorageandtoothbrushsimulationoncolorglossandroughnessofcadcamhandcastthermoformingand3dprintedsplintmaterials AT rosentrittmartin effectsofstorageandtoothbrushsimulationoncolorglossandroughnessofcadcamhandcastthermoformingand3dprintedsplintmaterials |