Cargando…

Brote nosocomial de COVID-19 en una planta de medicina interna: probable transmisión aérea

BACKGROUND AND OBJECTIVES: Despite the increasing evidence supporting the importance of airborne transmission in SARS-CoV-2 infection, it has not been considered relevant in the vast majority of reported nosocomial outbreaks of COVID-19. The aim of this study is to describe a nosocomial outbreak of...

Descripción completa

Detalles Bibliográficos
Autores principales: Andrés, M., García, M-C., Fajardo, A., Grau, L., Pagespetit, L., Plasencia, V., Martínez, I., Abadía, C., Sanahuja, A., Bella, F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier España, S.L.U. and Sociedad Española de Medicina Interna (SEMI). 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9072947/
https://www.ncbi.nlm.nih.gov/pubmed/35541500
http://dx.doi.org/10.1016/j.rce.2022.04.001
_version_ 1784701175646388224
author Andrés, M.
García, M-C.
Fajardo, A.
Grau, L.
Pagespetit, L.
Plasencia, V.
Martínez, I.
Abadía, C.
Sanahuja, A.
Bella, F.
author_facet Andrés, M.
García, M-C.
Fajardo, A.
Grau, L.
Pagespetit, L.
Plasencia, V.
Martínez, I.
Abadía, C.
Sanahuja, A.
Bella, F.
author_sort Andrés, M.
collection PubMed
description BACKGROUND AND OBJECTIVES: Despite the increasing evidence supporting the importance of airborne transmission in SARS-CoV-2 infection, it has not been considered relevant in the vast majority of reported nosocomial outbreaks of COVID-19. The aim of this study is to describe a nosocomial outbreak of SARS-CoV-2 infection whose features suggest that aerosol transmission had an important role. METHODS: This is a descriptive analysis of a nosocomial outbreak of SARS-CoV-2 infection in an internal medicine ward that occurred in December 2020. All cases were confirmed by a positive PCR test for SARS-CoV-2. RESULTS: From December 5 to December 17, 21 patients and 44 healthcare workers developed a nosocomial SARS-CoV-2 infection. Fifty-one of the 65 cases (78.5%) were diagnosed between December 6 and 9. The attack rate in patients was 80.8%. Among workers, the attack rate was higher in those who had worked at least one full working day in the ward (56.3%) than in those who had occasionally been in the ward (25.8%, p = 0.005). Three days before the first positive case was detected, 2 extractor fans were found to be defective, affecting the ventilation of 3 rooms. Sixteen cases were asymptomatic, 48 cases had non-severe symptoms, and 2 cases required admission to the intensive care unit. All patients eventually recovered. CONCLUSION: The high attack rate, the explosive nature of the outbreak, and the coincidence in time with the breakdown in air extractors in some rooms of the ward suggest that airborne transmission played a key role in the development of the outbreak.
format Online
Article
Text
id pubmed-9072947
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier España, S.L.U. and Sociedad Española de Medicina Interna (SEMI).
record_format MEDLINE/PubMed
spelling pubmed-90729472022-05-06 Brote nosocomial de COVID-19 en una planta de medicina interna: probable transmisión aérea Andrés, M. García, M-C. Fajardo, A. Grau, L. Pagespetit, L. Plasencia, V. Martínez, I. Abadía, C. Sanahuja, A. Bella, F. Rev Clin Esp Original BACKGROUND AND OBJECTIVES: Despite the increasing evidence supporting the importance of airborne transmission in SARS-CoV-2 infection, it has not been considered relevant in the vast majority of reported nosocomial outbreaks of COVID-19. The aim of this study is to describe a nosocomial outbreak of SARS-CoV-2 infection whose features suggest that aerosol transmission had an important role. METHODS: This is a descriptive analysis of a nosocomial outbreak of SARS-CoV-2 infection in an internal medicine ward that occurred in December 2020. All cases were confirmed by a positive PCR test for SARS-CoV-2. RESULTS: From December 5 to December 17, 21 patients and 44 healthcare workers developed a nosocomial SARS-CoV-2 infection. Fifty-one of the 65 cases (78.5%) were diagnosed between December 6 and 9. The attack rate in patients was 80.8%. Among workers, the attack rate was higher in those who had worked at least one full working day in the ward (56.3%) than in those who had occasionally been in the ward (25.8%, p = 0.005). Three days before the first positive case was detected, 2 extractor fans were found to be defective, affecting the ventilation of 3 rooms. Sixteen cases were asymptomatic, 48 cases had non-severe symptoms, and 2 cases required admission to the intensive care unit. All patients eventually recovered. CONCLUSION: The high attack rate, the explosive nature of the outbreak, and the coincidence in time with the breakdown in air extractors in some rooms of the ward suggest that airborne transmission played a key role in the development of the outbreak. Elsevier España, S.L.U. and Sociedad Española de Medicina Interna (SEMI). 2022-12 2022-05-06 /pmc/articles/PMC9072947/ /pubmed/35541500 http://dx.doi.org/10.1016/j.rce.2022.04.001 Text en © 2022 Elsevier España, S.L.U. and Sociedad Española de Medicina Interna (SEMI). All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Original
Andrés, M.
García, M-C.
Fajardo, A.
Grau, L.
Pagespetit, L.
Plasencia, V.
Martínez, I.
Abadía, C.
Sanahuja, A.
Bella, F.
Brote nosocomial de COVID-19 en una planta de medicina interna: probable transmisión aérea
title Brote nosocomial de COVID-19 en una planta de medicina interna: probable transmisión aérea
title_full Brote nosocomial de COVID-19 en una planta de medicina interna: probable transmisión aérea
title_fullStr Brote nosocomial de COVID-19 en una planta de medicina interna: probable transmisión aérea
title_full_unstemmed Brote nosocomial de COVID-19 en una planta de medicina interna: probable transmisión aérea
title_short Brote nosocomial de COVID-19 en una planta de medicina interna: probable transmisión aérea
title_sort brote nosocomial de covid-19 en una planta de medicina interna: probable transmisión aérea
topic Original
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9072947/
https://www.ncbi.nlm.nih.gov/pubmed/35541500
http://dx.doi.org/10.1016/j.rce.2022.04.001
work_keys_str_mv AT andresm brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea
AT garciamc brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea
AT fajardoa brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea
AT graul brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea
AT pagespetitl brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea
AT plasenciav brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea
AT martinezi brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea
AT abadiac brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea
AT sanahujaa brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea
AT bellaf brotenosocomialdecovid19enunaplantademedicinainternaprobabletransmisionaerea