Cargando…
Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures
INTRODUCTION: The locking attachment plate (LAP) can be added to a locking compression plate (LCP) to allow the fixation of locking screws bicortically around a femoral implant. We aimed to examine surgical and fracture characteristics associated with healing for periprosthetic femur fractures (PPFF...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9073115/ https://www.ncbi.nlm.nih.gov/pubmed/35529896 http://dx.doi.org/10.1177/21514593221100417 |
_version_ | 1784701214980571136 |
---|---|
author | Wall, Bryce Stambough, Jeffrey B Cherney, Steven M. Mears, Simon C |
author_facet | Wall, Bryce Stambough, Jeffrey B Cherney, Steven M. Mears, Simon C |
author_sort | Wall, Bryce |
collection | PubMed |
description | INTRODUCTION: The locking attachment plate (LAP) can be added to a locking compression plate (LCP) to allow the fixation of locking screws bicortically around a femoral implant. We aimed to examine surgical and fracture characteristics associated with healing for periprosthetic femur fractures (PPFFx) treated with constructs employing LAP fixation. We hypothesize that the addition of an LAP provides stable peri-implant fixation. MATERIALS &METHODS: We retrospectively reviewed a consecutive series of 28 PPFFx surgically treated with LCP-LAP constructs by 4 surgeons from 2015-2020. Fractures were classified and grouped using the Vancouver Classification System and included 12 B1, 2 B2, 11 C fractures, and 3 fractures around other stemmed implants. Primary outcome measures included hardware failure such as screw pullout, broken screws, and plate fracture. Clinical complications including infection, non-union, malunion, and reoperation were recorded. RESULTS: No LAP failures, screw pullout, or broken screws were observed. Two fractured plates (7.1%) occurred in patients with Vancouver C fracture types. Overall complication rate was 17.9% and included 3 non-unions, 1 deep infection, and 1 implant loosening with painful hardware, each requiring reoperation. Differences were observed between unions and nonunions for total number of screws (12.4 vs 14.7, P = .005) and number of locking screws used (8.04 vs 11.3, P = .03). CONCLUSION: The LAP provides adequate fixation and low failure rates where fixation is required around a well-fixed stem. When failures occur, it is from plate breakage and not due to failure of fixation at the area of plate-stem overlap. |
format | Online Article Text |
id | pubmed-9073115 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-90731152022-05-07 Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures Wall, Bryce Stambough, Jeffrey B Cherney, Steven M. Mears, Simon C Geriatr Orthop Surg Rehabil Resident Corner INTRODUCTION: The locking attachment plate (LAP) can be added to a locking compression plate (LCP) to allow the fixation of locking screws bicortically around a femoral implant. We aimed to examine surgical and fracture characteristics associated with healing for periprosthetic femur fractures (PPFFx) treated with constructs employing LAP fixation. We hypothesize that the addition of an LAP provides stable peri-implant fixation. MATERIALS &METHODS: We retrospectively reviewed a consecutive series of 28 PPFFx surgically treated with LCP-LAP constructs by 4 surgeons from 2015-2020. Fractures were classified and grouped using the Vancouver Classification System and included 12 B1, 2 B2, 11 C fractures, and 3 fractures around other stemmed implants. Primary outcome measures included hardware failure such as screw pullout, broken screws, and plate fracture. Clinical complications including infection, non-union, malunion, and reoperation were recorded. RESULTS: No LAP failures, screw pullout, or broken screws were observed. Two fractured plates (7.1%) occurred in patients with Vancouver C fracture types. Overall complication rate was 17.9% and included 3 non-unions, 1 deep infection, and 1 implant loosening with painful hardware, each requiring reoperation. Differences were observed between unions and nonunions for total number of screws (12.4 vs 14.7, P = .005) and number of locking screws used (8.04 vs 11.3, P = .03). CONCLUSION: The LAP provides adequate fixation and low failure rates where fixation is required around a well-fixed stem. When failures occur, it is from plate breakage and not due to failure of fixation at the area of plate-stem overlap. SAGE Publications 2022-05-03 /pmc/articles/PMC9073115/ /pubmed/35529896 http://dx.doi.org/10.1177/21514593221100417 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Resident Corner Wall, Bryce Stambough, Jeffrey B Cherney, Steven M. Mears, Simon C Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures |
title | Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures |
title_full | Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures |
title_fullStr | Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures |
title_full_unstemmed | Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures |
title_short | Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures |
title_sort | use of the locking attachment plate for internal fixation of periprosthetic femur fractures |
topic | Resident Corner |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9073115/ https://www.ncbi.nlm.nih.gov/pubmed/35529896 http://dx.doi.org/10.1177/21514593221100417 |
work_keys_str_mv | AT wallbryce useofthelockingattachmentplateforinternalfixationofperiprostheticfemurfractures AT stamboughjeffreyb useofthelockingattachmentplateforinternalfixationofperiprostheticfemurfractures AT cherneystevenm useofthelockingattachmentplateforinternalfixationofperiprostheticfemurfractures AT mearssimonc useofthelockingattachmentplateforinternalfixationofperiprostheticfemurfractures |