Cargando…
Rapid screening and quantification of multi-class antibiotic pollutants in water using a planar waveguide immunosensor
Antibiotics are commonly used in livestock-related agriculture and aquaculture, but they also remain in water and potentially threaten human health. Immunosensors are attractive tools for the rapid detection of antibiotics in water due to their high sensitivity and low costs. However, the simultaneo...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9075870/ https://www.ncbi.nlm.nih.gov/pubmed/35540241 http://dx.doi.org/10.1039/c9ra06796e |
_version_ | 1784701781606924288 |
---|---|
author | Zhang, Tianmu Li, Yijun Chen, Chunfei Liu, Xiaoping Tian, Yan Zeng, Siyu He, Miao |
author_facet | Zhang, Tianmu Li, Yijun Chen, Chunfei Liu, Xiaoping Tian, Yan Zeng, Siyu He, Miao |
author_sort | Zhang, Tianmu |
collection | PubMed |
description | Antibiotics are commonly used in livestock-related agriculture and aquaculture, but they also remain in water and potentially threaten human health. Immunosensors are attractive tools for the rapid detection of antibiotics in water due to their high sensitivity and low costs. However, the simultaneous detection of multi-class antibiotics remains a challenge due to the limited number of detection sites on the immunochip. Also, matrix effects hinder the practical application of these sensors. This paper presents a method for multi-class antibiotic detection in real water using a planar waveguide immunosensor (PWI). We integrate the screening and quantitive detection sites on the same immunochip, and a single screening detection site could detect multi-class antibiotics from the same family, increasing the detection types of analytes. In addition, to eliminate the matrix effects, we develop a testing buffer for real water detection, so that complex pretreatments of the samples can be omitted. Using our sensor and testing buffer, we detect 14 different antibiotics in real water. Lincomycin can be detected with a detection limit of 0.01 μg L(−1), and 13 quinolones can be screened in a single assay. These results demonstrate that this planar waveguide immunosensor is capable of simultaneous screening and quantification of multi-class antibiotic pollutants and is expected to be applied for practical environmental monitoring. |
format | Online Article Text |
id | pubmed-9075870 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-90758702022-05-09 Rapid screening and quantification of multi-class antibiotic pollutants in water using a planar waveguide immunosensor Zhang, Tianmu Li, Yijun Chen, Chunfei Liu, Xiaoping Tian, Yan Zeng, Siyu He, Miao RSC Adv Chemistry Antibiotics are commonly used in livestock-related agriculture and aquaculture, but they also remain in water and potentially threaten human health. Immunosensors are attractive tools for the rapid detection of antibiotics in water due to their high sensitivity and low costs. However, the simultaneous detection of multi-class antibiotics remains a challenge due to the limited number of detection sites on the immunochip. Also, matrix effects hinder the practical application of these sensors. This paper presents a method for multi-class antibiotic detection in real water using a planar waveguide immunosensor (PWI). We integrate the screening and quantitive detection sites on the same immunochip, and a single screening detection site could detect multi-class antibiotics from the same family, increasing the detection types of analytes. In addition, to eliminate the matrix effects, we develop a testing buffer for real water detection, so that complex pretreatments of the samples can be omitted. Using our sensor and testing buffer, we detect 14 different antibiotics in real water. Lincomycin can be detected with a detection limit of 0.01 μg L(−1), and 13 quinolones can be screened in a single assay. These results demonstrate that this planar waveguide immunosensor is capable of simultaneous screening and quantification of multi-class antibiotic pollutants and is expected to be applied for practical environmental monitoring. The Royal Society of Chemistry 2019-11-25 /pmc/articles/PMC9075870/ /pubmed/35540241 http://dx.doi.org/10.1039/c9ra06796e Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Zhang, Tianmu Li, Yijun Chen, Chunfei Liu, Xiaoping Tian, Yan Zeng, Siyu He, Miao Rapid screening and quantification of multi-class antibiotic pollutants in water using a planar waveguide immunosensor |
title | Rapid screening and quantification of multi-class antibiotic pollutants in water using a planar waveguide immunosensor |
title_full | Rapid screening and quantification of multi-class antibiotic pollutants in water using a planar waveguide immunosensor |
title_fullStr | Rapid screening and quantification of multi-class antibiotic pollutants in water using a planar waveguide immunosensor |
title_full_unstemmed | Rapid screening and quantification of multi-class antibiotic pollutants in water using a planar waveguide immunosensor |
title_short | Rapid screening and quantification of multi-class antibiotic pollutants in water using a planar waveguide immunosensor |
title_sort | rapid screening and quantification of multi-class antibiotic pollutants in water using a planar waveguide immunosensor |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9075870/ https://www.ncbi.nlm.nih.gov/pubmed/35540241 http://dx.doi.org/10.1039/c9ra06796e |
work_keys_str_mv | AT zhangtianmu rapidscreeningandquantificationofmulticlassantibioticpollutantsinwaterusingaplanarwaveguideimmunosensor AT liyijun rapidscreeningandquantificationofmulticlassantibioticpollutantsinwaterusingaplanarwaveguideimmunosensor AT chenchunfei rapidscreeningandquantificationofmulticlassantibioticpollutantsinwaterusingaplanarwaveguideimmunosensor AT liuxiaoping rapidscreeningandquantificationofmulticlassantibioticpollutantsinwaterusingaplanarwaveguideimmunosensor AT tianyan rapidscreeningandquantificationofmulticlassantibioticpollutantsinwaterusingaplanarwaveguideimmunosensor AT zengsiyu rapidscreeningandquantificationofmulticlassantibioticpollutantsinwaterusingaplanarwaveguideimmunosensor AT hemiao rapidscreeningandquantificationofmulticlassantibioticpollutantsinwaterusingaplanarwaveguideimmunosensor |