Cargando…
An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care
BACKGROUND: In specific clinical scenarios or with patient comorbid conditions, continuous blood pressure (BP) monitoring may be required as it can be expected to provide superior physiologic monitoring to intermittent techniques. However, continuous BP monitoring requires an arterial cannula (AC) p...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elmer Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9076136/ https://www.ncbi.nlm.nih.gov/pubmed/35573930 http://dx.doi.org/10.14740/jocmr4723 |
_version_ | 1784701846297772032 |
---|---|
author | Bekiroglu, Ismail Owusu-Bediako, Kwaku Rice-Weimer, Julie Tobias, Joseph D. |
author_facet | Bekiroglu, Ismail Owusu-Bediako, Kwaku Rice-Weimer, Julie Tobias, Joseph D. |
author_sort | Bekiroglu, Ismail |
collection | PubMed |
description | BACKGROUND: In specific clinical scenarios or with patient comorbid conditions, continuous blood pressure (BP) monitoring may be required as it can be expected to provide superior physiologic monitoring to intermittent techniques. However, continuous BP monitoring requires an arterial cannula (AC) placement, which may be time-consuming, technically challenging, or associated with adverse events. Various noninvasive BP devices have been developed which provide a continuous BP reading. The current study evaluates the accuracy of a novel continuous BP device, the NICCI monitor (NM), in pediatric patients weighing 10 - 40 kg. METHODS: The study cohort included pediatric patients weighing between 10 and 40 kg, scheduled for surgery for which placement of an AC was planned. Systolic (SBP), diastolic (DBP), and mean arterial (MAP) blood pressure readings were captured from the AC and the NM every second during anesthetic care. RESULTS: The study cohort included 24 pediatric patients undergoing major orthopedic, cardiac, and neurosurgical procedures. A total of 146,562 pairs of SBP, DBP, and MAP values from the AC and NC were analyzed. The absolute difference for the NM and the AC’s SBP, DBP, and MAP values were 11 ± 9, 10 ± 7, and 10 ± 7 mm Hg, respectively. The difference between the BP values from the NM and the AC was ≤ 10 mm Hg for 57% of the SBP readings, 60% of the DBP readings, and 56% of the MAP readings. The bias was 4, 4, and 6 mm Hg for the SBP, DBP, and MAP, respectively. CONCLUSIONS: Although there were some technical limitations given patient size, potentially resulting in variation in accuracy, the NM provided a continuous noninvasive BP measurement within clinically useful limits during a significant portion of anesthetic care compared to values obtained from an AC. Ongoing modification of the technology to improve its application in pediatric patients will likely increase its accuracy. |
format | Online Article Text |
id | pubmed-9076136 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elmer Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-90761362022-05-12 An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care Bekiroglu, Ismail Owusu-Bediako, Kwaku Rice-Weimer, Julie Tobias, Joseph D. J Clin Med Res Original Article BACKGROUND: In specific clinical scenarios or with patient comorbid conditions, continuous blood pressure (BP) monitoring may be required as it can be expected to provide superior physiologic monitoring to intermittent techniques. However, continuous BP monitoring requires an arterial cannula (AC) placement, which may be time-consuming, technically challenging, or associated with adverse events. Various noninvasive BP devices have been developed which provide a continuous BP reading. The current study evaluates the accuracy of a novel continuous BP device, the NICCI monitor (NM), in pediatric patients weighing 10 - 40 kg. METHODS: The study cohort included pediatric patients weighing between 10 and 40 kg, scheduled for surgery for which placement of an AC was planned. Systolic (SBP), diastolic (DBP), and mean arterial (MAP) blood pressure readings were captured from the AC and the NM every second during anesthetic care. RESULTS: The study cohort included 24 pediatric patients undergoing major orthopedic, cardiac, and neurosurgical procedures. A total of 146,562 pairs of SBP, DBP, and MAP values from the AC and NC were analyzed. The absolute difference for the NM and the AC’s SBP, DBP, and MAP values were 11 ± 9, 10 ± 7, and 10 ± 7 mm Hg, respectively. The difference between the BP values from the NM and the AC was ≤ 10 mm Hg for 57% of the SBP readings, 60% of the DBP readings, and 56% of the MAP readings. The bias was 4, 4, and 6 mm Hg for the SBP, DBP, and MAP, respectively. CONCLUSIONS: Although there were some technical limitations given patient size, potentially resulting in variation in accuracy, the NM provided a continuous noninvasive BP measurement within clinically useful limits during a significant portion of anesthetic care compared to values obtained from an AC. Ongoing modification of the technology to improve its application in pediatric patients will likely increase its accuracy. Elmer Press 2022-04 2022-04-30 /pmc/articles/PMC9076136/ /pubmed/35573930 http://dx.doi.org/10.14740/jocmr4723 Text en Copyright 2022, Bekiroglu et al. https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Bekiroglu, Ismail Owusu-Bediako, Kwaku Rice-Weimer, Julie Tobias, Joseph D. An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care |
title | An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care |
title_full | An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care |
title_fullStr | An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care |
title_full_unstemmed | An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care |
title_short | An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care |
title_sort | evaluation of the nicci monitor in providing continuous, noninvasive blood pressure readings in children during intraoperative anesthetic care |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9076136/ https://www.ncbi.nlm.nih.gov/pubmed/35573930 http://dx.doi.org/10.14740/jocmr4723 |
work_keys_str_mv | AT bekirogluismail anevaluationoftheniccimonitorinprovidingcontinuousnoninvasivebloodpressurereadingsinchildrenduringintraoperativeanestheticcare AT owusubediakokwaku anevaluationoftheniccimonitorinprovidingcontinuousnoninvasivebloodpressurereadingsinchildrenduringintraoperativeanestheticcare AT riceweimerjulie anevaluationoftheniccimonitorinprovidingcontinuousnoninvasivebloodpressurereadingsinchildrenduringintraoperativeanestheticcare AT tobiasjosephd anevaluationoftheniccimonitorinprovidingcontinuousnoninvasivebloodpressurereadingsinchildrenduringintraoperativeanestheticcare AT bekirogluismail evaluationoftheniccimonitorinprovidingcontinuousnoninvasivebloodpressurereadingsinchildrenduringintraoperativeanestheticcare AT owusubediakokwaku evaluationoftheniccimonitorinprovidingcontinuousnoninvasivebloodpressurereadingsinchildrenduringintraoperativeanestheticcare AT riceweimerjulie evaluationoftheniccimonitorinprovidingcontinuousnoninvasivebloodpressurereadingsinchildrenduringintraoperativeanestheticcare AT tobiasjosephd evaluationoftheniccimonitorinprovidingcontinuousnoninvasivebloodpressurereadingsinchildrenduringintraoperativeanestheticcare |