Cargando…
Digital Workflow for Immediate Implant Placement and Chairside Provisionalization in the Esthetic Zone
INTRODUCTION: Immediate implant placement and immediate chairside provisionalization in the esthetic zone require meticulous treatment planning. A digital workflow that combines intraoral scans and a cone beam computed tomography scan can be used to visualize the surgical and restorative aspects of...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9076344/ https://www.ncbi.nlm.nih.gov/pubmed/35527725 http://dx.doi.org/10.1155/2022/5114332 |
_version_ | 1784701902771978240 |
---|---|
author | Donker, Vincent J. J. Raghoebar, Gerry M. Vissink, Arjan Meijer, Henny J. A. |
author_facet | Donker, Vincent J. J. Raghoebar, Gerry M. Vissink, Arjan Meijer, Henny J. A. |
author_sort | Donker, Vincent J. J. |
collection | PubMed |
description | INTRODUCTION: Immediate implant placement and immediate chairside provisionalization in the esthetic zone require meticulous treatment planning. A digital workflow that combines intraoral scans and a cone beam computed tomography scan can be used to visualize the surgical and restorative aspects of the treatment and to plan a prosthetically driven implant position. A digital workflow in implant dentistry enables the prefabrication of an individualized CAD/CAM temporary restoration, based on the planned implant position. This could be a predictable method to deliver a screw-retained temporary restoration, directly after static computer-assisted immediate implant surgery. Interventions. Three patients with a failing tooth in the maxillary esthetic zone were treated with immediate implant placement and chairside provisionalization using this digital workflow. After 3 months, a final restoration was placed. Clinical, radiographic, and patient-reported outcome measures were collected prior to implant treatment, 6 weeks after placing the temporary restoration and then 1 month and 1 year after placing the final restoration. Outcomes. At the 1-year follow-up, healthy soft tissues were observed, and peri-implant bone levels were stable. Patient satisfaction after the treatment was high. CONCLUSION: The three reported cases demonstrate the potential for predictable immediate implant placement and chairside provisionalization using a digital workflow. |
format | Online Article Text |
id | pubmed-9076344 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-90763442022-05-07 Digital Workflow for Immediate Implant Placement and Chairside Provisionalization in the Esthetic Zone Donker, Vincent J. J. Raghoebar, Gerry M. Vissink, Arjan Meijer, Henny J. A. Case Rep Dent Case Report INTRODUCTION: Immediate implant placement and immediate chairside provisionalization in the esthetic zone require meticulous treatment planning. A digital workflow that combines intraoral scans and a cone beam computed tomography scan can be used to visualize the surgical and restorative aspects of the treatment and to plan a prosthetically driven implant position. A digital workflow in implant dentistry enables the prefabrication of an individualized CAD/CAM temporary restoration, based on the planned implant position. This could be a predictable method to deliver a screw-retained temporary restoration, directly after static computer-assisted immediate implant surgery. Interventions. Three patients with a failing tooth in the maxillary esthetic zone were treated with immediate implant placement and chairside provisionalization using this digital workflow. After 3 months, a final restoration was placed. Clinical, radiographic, and patient-reported outcome measures were collected prior to implant treatment, 6 weeks after placing the temporary restoration and then 1 month and 1 year after placing the final restoration. Outcomes. At the 1-year follow-up, healthy soft tissues were observed, and peri-implant bone levels were stable. Patient satisfaction after the treatment was high. CONCLUSION: The three reported cases demonstrate the potential for predictable immediate implant placement and chairside provisionalization using a digital workflow. Hindawi 2022-04-01 /pmc/articles/PMC9076344/ /pubmed/35527725 http://dx.doi.org/10.1155/2022/5114332 Text en Copyright © 2022 Vincent J. J. Donker et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Donker, Vincent J. J. Raghoebar, Gerry M. Vissink, Arjan Meijer, Henny J. A. Digital Workflow for Immediate Implant Placement and Chairside Provisionalization in the Esthetic Zone |
title | Digital Workflow for Immediate Implant Placement and Chairside Provisionalization in the Esthetic Zone |
title_full | Digital Workflow for Immediate Implant Placement and Chairside Provisionalization in the Esthetic Zone |
title_fullStr | Digital Workflow for Immediate Implant Placement and Chairside Provisionalization in the Esthetic Zone |
title_full_unstemmed | Digital Workflow for Immediate Implant Placement and Chairside Provisionalization in the Esthetic Zone |
title_short | Digital Workflow for Immediate Implant Placement and Chairside Provisionalization in the Esthetic Zone |
title_sort | digital workflow for immediate implant placement and chairside provisionalization in the esthetic zone |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9076344/ https://www.ncbi.nlm.nih.gov/pubmed/35527725 http://dx.doi.org/10.1155/2022/5114332 |
work_keys_str_mv | AT donkervincentjj digitalworkflowforimmediateimplantplacementandchairsideprovisionalizationintheestheticzone AT raghoebargerrym digitalworkflowforimmediateimplantplacementandchairsideprovisionalizationintheestheticzone AT vissinkarjan digitalworkflowforimmediateimplantplacementandchairsideprovisionalizationintheestheticzone AT meijerhennyja digitalworkflowforimmediateimplantplacementandchairsideprovisionalizationintheestheticzone |