Cargando…

Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system

BACKGROUND: A new compact superconducting synchrocyclotron single-room proton solution delivers pulsed proton beams to each spot through several irradiation bursts calculated by an iterative layer delivery algorithm. Such a mechanism results in a new beam parameter, burst switching time (BST) in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Lewei, Liu, Gang, Chen, Shupeng, Shen, Jiajian, Zheng, Weili, Qin, An, Yan, Di, Li, Xiaoqiang, Ding, Xuanfeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9077949/
https://www.ncbi.nlm.nih.gov/pubmed/35525993
http://dx.doi.org/10.1186/s13014-022-02055-w
_version_ 1784702222717681664
author Zhao, Lewei
Liu, Gang
Chen, Shupeng
Shen, Jiajian
Zheng, Weili
Qin, An
Yan, Di
Li, Xiaoqiang
Ding, Xuanfeng
author_facet Zhao, Lewei
Liu, Gang
Chen, Shupeng
Shen, Jiajian
Zheng, Weili
Qin, An
Yan, Di
Li, Xiaoqiang
Ding, Xuanfeng
author_sort Zhao, Lewei
collection PubMed
description BACKGROUND: A new compact superconducting synchrocyclotron single-room proton solution delivers pulsed proton beams to each spot through several irradiation bursts calculated by an iterative layer delivery algorithm. Such a mechanism results in a new beam parameter, burst switching time (BST) in the total beam delivery time (BDT) which has never been studied before. In this study, we propose an experimental approach to build an accurate BDT and sequence prediction model for this new proton solution. METHODS: Test fields and clinical treatment plans were used to investigate each beam delivery parameter that impacted BDT. The machine delivery log files were retrospectively analyzed to quantitatively model energy layer switching time (ELST), spot switching time (SSWT), spot spill time (SSPT), and BST. A total of 102 clinical IMPT treatment fields’ log files were processed to validate the accuracy of the BDT prediction model in comparison with the result from the current commercial system. Interplay effect is also investigated as a clinical application by comparing this new delivery system model with a conventional cyclotron accelerator model. RESULTS: The study finds that BST depends on the amount of data to be transmitted between two sequential radiation bursts, including a machine irradiation log file of the previous burst and a command file to instruct the proton system to deliver the next burst. The 102 clinical treatment fields showed that the accuracy of each component of the BDT matches well between machine log files and BDT prediction model. More specifically, the difference of ELST, SSWT, SSPT, and BST were (− 3.1 ± 5.7)%, (5.9 ± 3.9)%, (2.6 ± 8.7)%, and (− 2.3 ± 5.3)%, respectively. The average total BDT was about (2.1 ± 3.0)% difference compared to the treatment log files, which was significantly improved from the current commercial proton system prediction (58 ± 15)%. Compared to the conventional cyclotron system, the burst technique from synchrocyclotron effectively reduced the interplay effect in mobile tumor treatment. CONCLUSION: An accurate BDT and sequence prediction model was established for this new clinical compact superconducting synchrocyclotron single-room proton solution. Its application could help users of similar facilities better assess the interplay effect and estimate daily patient treatment throughput. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-022-02055-w.
format Online
Article
Text
id pubmed-9077949
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-90779492022-05-08 Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system Zhao, Lewei Liu, Gang Chen, Shupeng Shen, Jiajian Zheng, Weili Qin, An Yan, Di Li, Xiaoqiang Ding, Xuanfeng Radiat Oncol Methodology BACKGROUND: A new compact superconducting synchrocyclotron single-room proton solution delivers pulsed proton beams to each spot through several irradiation bursts calculated by an iterative layer delivery algorithm. Such a mechanism results in a new beam parameter, burst switching time (BST) in the total beam delivery time (BDT) which has never been studied before. In this study, we propose an experimental approach to build an accurate BDT and sequence prediction model for this new proton solution. METHODS: Test fields and clinical treatment plans were used to investigate each beam delivery parameter that impacted BDT. The machine delivery log files were retrospectively analyzed to quantitatively model energy layer switching time (ELST), spot switching time (SSWT), spot spill time (SSPT), and BST. A total of 102 clinical IMPT treatment fields’ log files were processed to validate the accuracy of the BDT prediction model in comparison with the result from the current commercial system. Interplay effect is also investigated as a clinical application by comparing this new delivery system model with a conventional cyclotron accelerator model. RESULTS: The study finds that BST depends on the amount of data to be transmitted between two sequential radiation bursts, including a machine irradiation log file of the previous burst and a command file to instruct the proton system to deliver the next burst. The 102 clinical treatment fields showed that the accuracy of each component of the BDT matches well between machine log files and BDT prediction model. More specifically, the difference of ELST, SSWT, SSPT, and BST were (− 3.1 ± 5.7)%, (5.9 ± 3.9)%, (2.6 ± 8.7)%, and (− 2.3 ± 5.3)%, respectively. The average total BDT was about (2.1 ± 3.0)% difference compared to the treatment log files, which was significantly improved from the current commercial proton system prediction (58 ± 15)%. Compared to the conventional cyclotron system, the burst technique from synchrocyclotron effectively reduced the interplay effect in mobile tumor treatment. CONCLUSION: An accurate BDT and sequence prediction model was established for this new clinical compact superconducting synchrocyclotron single-room proton solution. Its application could help users of similar facilities better assess the interplay effect and estimate daily patient treatment throughput. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-022-02055-w. BioMed Central 2022-05-07 /pmc/articles/PMC9077949/ /pubmed/35525993 http://dx.doi.org/10.1186/s13014-022-02055-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Methodology
Zhao, Lewei
Liu, Gang
Chen, Shupeng
Shen, Jiajian
Zheng, Weili
Qin, An
Yan, Di
Li, Xiaoqiang
Ding, Xuanfeng
Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system
title Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system
title_full Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system
title_fullStr Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system
title_full_unstemmed Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system
title_short Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system
title_sort developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9077949/
https://www.ncbi.nlm.nih.gov/pubmed/35525993
http://dx.doi.org/10.1186/s13014-022-02055-w
work_keys_str_mv AT zhaolewei developinganaccuratemodelofspotscanningtreatmentdeliverytimeandsequenceforacompactsuperconductingsynchrocyclotronprotontherapysystem
AT liugang developinganaccuratemodelofspotscanningtreatmentdeliverytimeandsequenceforacompactsuperconductingsynchrocyclotronprotontherapysystem
AT chenshupeng developinganaccuratemodelofspotscanningtreatmentdeliverytimeandsequenceforacompactsuperconductingsynchrocyclotronprotontherapysystem
AT shenjiajian developinganaccuratemodelofspotscanningtreatmentdeliverytimeandsequenceforacompactsuperconductingsynchrocyclotronprotontherapysystem
AT zhengweili developinganaccuratemodelofspotscanningtreatmentdeliverytimeandsequenceforacompactsuperconductingsynchrocyclotronprotontherapysystem
AT qinan developinganaccuratemodelofspotscanningtreatmentdeliverytimeandsequenceforacompactsuperconductingsynchrocyclotronprotontherapysystem
AT yandi developinganaccuratemodelofspotscanningtreatmentdeliverytimeandsequenceforacompactsuperconductingsynchrocyclotronprotontherapysystem
AT lixiaoqiang developinganaccuratemodelofspotscanningtreatmentdeliverytimeandsequenceforacompactsuperconductingsynchrocyclotronprotontherapysystem
AT dingxuanfeng developinganaccuratemodelofspotscanningtreatmentdeliverytimeandsequenceforacompactsuperconductingsynchrocyclotronprotontherapysystem