Cargando…

Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media

The electrochemical behavior of phenolic isomers hydroquinone (HQ), catechol (CC) and resorcinol (RC) was examined in poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode (P1,5-DAN/GC M.E.) by cyclic voltammetry (CV), square wave voltammetry (SWV) and chronoamperometry (CA) techniques in pe...

Descripción completa

Detalles Bibliográficos
Autores principales: Hassan, Khalid Mahmoud, Hathoot, Abla Ahmed, Abo oura, Mohamed Fathi, Azzem, Magdi Abdel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9078241/
https://www.ncbi.nlm.nih.gov/pubmed/35540423
http://dx.doi.org/10.1039/c7ra13665j
_version_ 1784702285248462848
author Hassan, Khalid Mahmoud
Hathoot, Abla Ahmed
Abo oura, Mohamed Fathi
Azzem, Magdi Abdel
author_facet Hassan, Khalid Mahmoud
Hathoot, Abla Ahmed
Abo oura, Mohamed Fathi
Azzem, Magdi Abdel
author_sort Hassan, Khalid Mahmoud
collection PubMed
description The electrochemical behavior of phenolic isomers hydroquinone (HQ), catechol (CC) and resorcinol (RC) was examined in poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode (P1,5-DAN/GC M.E.) by cyclic voltammetry (CV), square wave voltammetry (SWV) and chronoamperometry (CA) techniques in perchloric acid (HClO(4)) and phosphate buffer solution (PBS, pH 7.0). P1,5-DAN/GC M.E. was investigated for simultaneous determination of HQ, CC and RC in single, binary and ternary systems. Oxidation peak potentials were negatively shifted with increasing oxidation peak current for HQ, CC and RC at P1,5-DAN/GC M.E. compared with bare GC electrode. The obtained results illustrate that the former electrode exhibits better performance towards the three isomers in PBS rather than in HClO(4) solution. The catalytic currents for different concentrations of HQ, CC and RC showed good relationship in the range of 0.1–100 μM for all analytes and low detection limits (LOD) of 0.034, 0.059 and 0.14 μM for them, respectively, in a ternary system in PBS at pH 7.0. This method has been practically applied for the detection of these isomers in tap water with acceptable results.
format Online
Article
Text
id pubmed-9078241
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90782412022-05-09 Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media Hassan, Khalid Mahmoud Hathoot, Abla Ahmed Abo oura, Mohamed Fathi Azzem, Magdi Abdel RSC Adv Chemistry The electrochemical behavior of phenolic isomers hydroquinone (HQ), catechol (CC) and resorcinol (RC) was examined in poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode (P1,5-DAN/GC M.E.) by cyclic voltammetry (CV), square wave voltammetry (SWV) and chronoamperometry (CA) techniques in perchloric acid (HClO(4)) and phosphate buffer solution (PBS, pH 7.0). P1,5-DAN/GC M.E. was investigated for simultaneous determination of HQ, CC and RC in single, binary and ternary systems. Oxidation peak potentials were negatively shifted with increasing oxidation peak current for HQ, CC and RC at P1,5-DAN/GC M.E. compared with bare GC electrode. The obtained results illustrate that the former electrode exhibits better performance towards the three isomers in PBS rather than in HClO(4) solution. The catalytic currents for different concentrations of HQ, CC and RC showed good relationship in the range of 0.1–100 μM for all analytes and low detection limits (LOD) of 0.034, 0.059 and 0.14 μM for them, respectively, in a ternary system in PBS at pH 7.0. This method has been practically applied for the detection of these isomers in tap water with acceptable results. The Royal Society of Chemistry 2018-02-07 /pmc/articles/PMC9078241/ /pubmed/35540423 http://dx.doi.org/10.1039/c7ra13665j Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Hassan, Khalid Mahmoud
Hathoot, Abla Ahmed
Abo oura, Mohamed Fathi
Azzem, Magdi Abdel
Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media
title Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media
title_full Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media
title_fullStr Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media
title_full_unstemmed Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media
title_short Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media
title_sort simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9078241/
https://www.ncbi.nlm.nih.gov/pubmed/35540423
http://dx.doi.org/10.1039/c7ra13665j
work_keys_str_mv AT hassankhalidmahmoud simultaneousandselectiveelectrochemicaldeterminationofhydroquinonecatecholandresorcinolatpoly15diaminonaphthaleneglassycarbonmodifiedelectrodeindifferentmedia
AT hathootablaahmed simultaneousandselectiveelectrochemicaldeterminationofhydroquinonecatecholandresorcinolatpoly15diaminonaphthaleneglassycarbonmodifiedelectrodeindifferentmedia
AT aboouramohamedfathi simultaneousandselectiveelectrochemicaldeterminationofhydroquinonecatecholandresorcinolatpoly15diaminonaphthaleneglassycarbonmodifiedelectrodeindifferentmedia
AT azzemmagdiabdel simultaneousandselectiveelectrochemicaldeterminationofhydroquinonecatecholandresorcinolatpoly15diaminonaphthaleneglassycarbonmodifiedelectrodeindifferentmedia