Cargando…
Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications
The major drawback of Fe-based materials for biodegradable implant applications is their slow degradation rate. Addition of second phase particles into the Fe matrix can increase the degradation rate at the beginning of the corrosion process. However, so far, there is neither quantitative data on in...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9078673/ https://www.ncbi.nlm.nih.gov/pubmed/35540863 http://dx.doi.org/10.1039/c8ra00404h |
_version_ | 1784702386966626304 |
---|---|
author | Sikora-Jasinska, M. Chevallier, P. Turgeon, S. Paternoster, C. Mostaed, E. Vedani, M. Mantovani, D. |
author_facet | Sikora-Jasinska, M. Chevallier, P. Turgeon, S. Paternoster, C. Mostaed, E. Vedani, M. Mantovani, D. |
author_sort | Sikora-Jasinska, M. |
collection | PubMed |
description | The major drawback of Fe-based materials for biodegradable implant applications is their slow degradation rate. Addition of second phase particles into the Fe matrix can increase the degradation rate at the beginning of the corrosion process. However, so far, there is neither quantitative data on in vitro degradation nor direct experimental evidence for long-term dissolution of Fe-based biodegradable composites. Here, a series of immersion tests at different exposure intervals (20, 50 and 100 days) to modified Hanks' solution were performed to study the degradation behavior of Fe and Fe/Mg(2)Si composites prepared by different powder metallurgy techniques. The results revealed the role of Mg(2)Si in the composition and stability of the protective films formed during the static corrosion experiments. Fe/Mg(2)Si composites showed higher degradation rates than those of pure Fe at all stages of immersion. Degradation rates at distinct exposure intervals strongly depended on the composition and stability of formed oxide, hydroxide, carbonate and phosphate protective films on the degraded surfaces. The release of Fe ions into the solution at later stages of the experiment was limited due to the barrier effect of the insoluble deposit. This fundamental study provided a basis for the processes of protective film formation in modified Hanks' solution, which enables a detailed identification of its characteristic features. |
format | Online Article Text |
id | pubmed-9078673 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-90786732022-05-09 Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications Sikora-Jasinska, M. Chevallier, P. Turgeon, S. Paternoster, C. Mostaed, E. Vedani, M. Mantovani, D. RSC Adv Chemistry The major drawback of Fe-based materials for biodegradable implant applications is their slow degradation rate. Addition of second phase particles into the Fe matrix can increase the degradation rate at the beginning of the corrosion process. However, so far, there is neither quantitative data on in vitro degradation nor direct experimental evidence for long-term dissolution of Fe-based biodegradable composites. Here, a series of immersion tests at different exposure intervals (20, 50 and 100 days) to modified Hanks' solution were performed to study the degradation behavior of Fe and Fe/Mg(2)Si composites prepared by different powder metallurgy techniques. The results revealed the role of Mg(2)Si in the composition and stability of the protective films formed during the static corrosion experiments. Fe/Mg(2)Si composites showed higher degradation rates than those of pure Fe at all stages of immersion. Degradation rates at distinct exposure intervals strongly depended on the composition and stability of formed oxide, hydroxide, carbonate and phosphate protective films on the degraded surfaces. The release of Fe ions into the solution at later stages of the experiment was limited due to the barrier effect of the insoluble deposit. This fundamental study provided a basis for the processes of protective film formation in modified Hanks' solution, which enables a detailed identification of its characteristic features. The Royal Society of Chemistry 2018-03-06 /pmc/articles/PMC9078673/ /pubmed/35540863 http://dx.doi.org/10.1039/c8ra00404h Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/ |
spellingShingle | Chemistry Sikora-Jasinska, M. Chevallier, P. Turgeon, S. Paternoster, C. Mostaed, E. Vedani, M. Mantovani, D. Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications |
title | Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications |
title_full | Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications |
title_fullStr | Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications |
title_full_unstemmed | Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications |
title_short | Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications |
title_sort | long-term in vitro degradation behaviour of fe and fe/mg(2)si composites for biodegradable implant applications |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9078673/ https://www.ncbi.nlm.nih.gov/pubmed/35540863 http://dx.doi.org/10.1039/c8ra00404h |
work_keys_str_mv | AT sikorajasinskam longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications AT chevallierp longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications AT turgeons longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications AT paternosterc longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications AT mostaede longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications AT vedanim longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications AT mantovanid longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications |