Cargando…

Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications

The major drawback of Fe-based materials for biodegradable implant applications is their slow degradation rate. Addition of second phase particles into the Fe matrix can increase the degradation rate at the beginning of the corrosion process. However, so far, there is neither quantitative data on in...

Descripción completa

Detalles Bibliográficos
Autores principales: Sikora-Jasinska, M., Chevallier, P., Turgeon, S., Paternoster, C., Mostaed, E., Vedani, M., Mantovani, D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9078673/
https://www.ncbi.nlm.nih.gov/pubmed/35540863
http://dx.doi.org/10.1039/c8ra00404h
_version_ 1784702386966626304
author Sikora-Jasinska, M.
Chevallier, P.
Turgeon, S.
Paternoster, C.
Mostaed, E.
Vedani, M.
Mantovani, D.
author_facet Sikora-Jasinska, M.
Chevallier, P.
Turgeon, S.
Paternoster, C.
Mostaed, E.
Vedani, M.
Mantovani, D.
author_sort Sikora-Jasinska, M.
collection PubMed
description The major drawback of Fe-based materials for biodegradable implant applications is their slow degradation rate. Addition of second phase particles into the Fe matrix can increase the degradation rate at the beginning of the corrosion process. However, so far, there is neither quantitative data on in vitro degradation nor direct experimental evidence for long-term dissolution of Fe-based biodegradable composites. Here, a series of immersion tests at different exposure intervals (20, 50 and 100 days) to modified Hanks' solution were performed to study the degradation behavior of Fe and Fe/Mg(2)Si composites prepared by different powder metallurgy techniques. The results revealed the role of Mg(2)Si in the composition and stability of the protective films formed during the static corrosion experiments. Fe/Mg(2)Si composites showed higher degradation rates than those of pure Fe at all stages of immersion. Degradation rates at distinct exposure intervals strongly depended on the composition and stability of formed oxide, hydroxide, carbonate and phosphate protective films on the degraded surfaces. The release of Fe ions into the solution at later stages of the experiment was limited due to the barrier effect of the insoluble deposit. This fundamental study provided a basis for the processes of protective film formation in modified Hanks' solution, which enables a detailed identification of its characteristic features.
format Online
Article
Text
id pubmed-9078673
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90786732022-05-09 Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications Sikora-Jasinska, M. Chevallier, P. Turgeon, S. Paternoster, C. Mostaed, E. Vedani, M. Mantovani, D. RSC Adv Chemistry The major drawback of Fe-based materials for biodegradable implant applications is their slow degradation rate. Addition of second phase particles into the Fe matrix can increase the degradation rate at the beginning of the corrosion process. However, so far, there is neither quantitative data on in vitro degradation nor direct experimental evidence for long-term dissolution of Fe-based biodegradable composites. Here, a series of immersion tests at different exposure intervals (20, 50 and 100 days) to modified Hanks' solution were performed to study the degradation behavior of Fe and Fe/Mg(2)Si composites prepared by different powder metallurgy techniques. The results revealed the role of Mg(2)Si in the composition and stability of the protective films formed during the static corrosion experiments. Fe/Mg(2)Si composites showed higher degradation rates than those of pure Fe at all stages of immersion. Degradation rates at distinct exposure intervals strongly depended on the composition and stability of formed oxide, hydroxide, carbonate and phosphate protective films on the degraded surfaces. The release of Fe ions into the solution at later stages of the experiment was limited due to the barrier effect of the insoluble deposit. This fundamental study provided a basis for the processes of protective film formation in modified Hanks' solution, which enables a detailed identification of its characteristic features. The Royal Society of Chemistry 2018-03-06 /pmc/articles/PMC9078673/ /pubmed/35540863 http://dx.doi.org/10.1039/c8ra00404h Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Sikora-Jasinska, M.
Chevallier, P.
Turgeon, S.
Paternoster, C.
Mostaed, E.
Vedani, M.
Mantovani, D.
Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications
title Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications
title_full Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications
title_fullStr Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications
title_full_unstemmed Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications
title_short Long-term in vitro degradation behaviour of Fe and Fe/Mg(2)Si composites for biodegradable implant applications
title_sort long-term in vitro degradation behaviour of fe and fe/mg(2)si composites for biodegradable implant applications
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9078673/
https://www.ncbi.nlm.nih.gov/pubmed/35540863
http://dx.doi.org/10.1039/c8ra00404h
work_keys_str_mv AT sikorajasinskam longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications
AT chevallierp longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications
AT turgeons longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications
AT paternosterc longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications
AT mostaede longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications
AT vedanim longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications
AT mantovanid longterminvitrodegradationbehaviouroffeandfemg2sicompositesforbiodegradableimplantapplications