Automated aortic endovascular balloon volume titration prevents re-arrest immediately after return of spontaneous circulation in a swine model of nontraumatic cardiac arrest
OBJECTIVES: Endovascular aortic occlusion as an adjunct to cardiopulmonary resuscitation (CPR) for non-traumatic cardiac arrest is gaining interest. In a recent clinical trial, return of spontaneous circulation (ROSC) was achieved despite prolonged no-flow times. However, 66% of patients re-arrested...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9079240/ https://www.ncbi.nlm.nih.gov/pubmed/35542691 http://dx.doi.org/10.1016/j.resplu.2022.100239 |
Sumario: | OBJECTIVES: Endovascular aortic occlusion as an adjunct to cardiopulmonary resuscitation (CPR) for non-traumatic cardiac arrest is gaining interest. In a recent clinical trial, return of spontaneous circulation (ROSC) was achieved despite prolonged no-flow times. However, 66% of patients re-arrested upon balloon deflation. We aimed to determine if automated titration of endovascular balloon volume following ROSC can augment diastolic blood pressure (DBP) to prevent re-arrest. METHODS: Twenty swine were anesthetized and placed into ventricular fibrillation (VF). Following 7 minutes of no-flow VF and 5 minutes of mechanical CPR, animals were subjected to complete aortic occlusion to adjunct CPR. Upon ROSC, the balloon was either deflated steadily over 5 minutes (control) or underwent automated, dynamic adjustments to maintain a DBP of 60 mmHg (Endovascular Variable Aortic Control, EVAC). RESULTS: ROSC was obtained in ten animals (5 EVAC, 5 REBOA). Sixty percent (3/5) of control animals rearrested while none of the EVAC animals rearrested (p = 0.038). Animals in the EVAC group spent a significantly higher proportion of the post-ROSC period with a DBP > 60 mmHg [median (IQR)] [control 79.7 (72.5–86.0)%; EVAC 97.7 (90.8–99.7)%, p = 0.047]. The EVAC group had a statistically significant reduction in arterial lactate concentration [7.98 (7.4–8.16) mmol/L] compared to control [9.93 (8.86–10.45) mmol/L, p = 0.047]. There were no statistical differences between the two groups in the amount of adrenaline (epinephrine) required. CONCLUSION: In our swine model of cardiac arrest, automated aortic endovascular balloon titration improved DBP and prevented re-arrest in the first 20 minutes after ROSC. |
---|