Cargando…
A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes
In this work, based on the superior electrochemical stability of Li(4)Ti(5)O(12) (LTO) electrodes, LiFePO(4) (LFP)/graphite cells with built-in LTO electrodes as reference electrodes were designed and fabricated. The characteristics of the LTO reference electrodes in the fabricated lithium-ion cells...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9080700/ https://www.ncbi.nlm.nih.gov/pubmed/35541153 http://dx.doi.org/10.1039/c8ra03062f |
_version_ | 1784702847753912320 |
---|---|
author | Yi, Shouzhong Wang, Bo Chen, Ziang Wang, Rui Wang, Dianlong |
author_facet | Yi, Shouzhong Wang, Bo Chen, Ziang Wang, Rui Wang, Dianlong |
author_sort | Yi, Shouzhong |
collection | PubMed |
description | In this work, based on the superior electrochemical stability of Li(4)Ti(5)O(12) (LTO) electrodes, LiFePO(4) (LFP)/graphite cells with built-in LTO electrodes as reference electrodes were designed and fabricated. The characteristics of the LTO reference electrodes in the fabricated lithium-ion cells were measured and discussed. The experimental data demonstrated that the LTO built-in reference electrodes were simple to prepare and were feasible options for long-term in situ monitoring of the development of potentials and other electrochemical parameters, such as the Li(+) diffusion coefficient (D(Li)) and electrochemical impedance spectroscopy (EIS) information, for both anodes and cathodes. Moreover, it is believed that the adoption of LTO as a reference electrode could be of great significance for long-term monitoring of the charge and discharge behavior of individual electrodes in other kinds of lithium-ion cells. |
format | Online Article Text |
id | pubmed-9080700 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-90807002022-05-09 A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes Yi, Shouzhong Wang, Bo Chen, Ziang Wang, Rui Wang, Dianlong RSC Adv Chemistry In this work, based on the superior electrochemical stability of Li(4)Ti(5)O(12) (LTO) electrodes, LiFePO(4) (LFP)/graphite cells with built-in LTO electrodes as reference electrodes were designed and fabricated. The characteristics of the LTO reference electrodes in the fabricated lithium-ion cells were measured and discussed. The experimental data demonstrated that the LTO built-in reference electrodes were simple to prepare and were feasible options for long-term in situ monitoring of the development of potentials and other electrochemical parameters, such as the Li(+) diffusion coefficient (D(Li)) and electrochemical impedance spectroscopy (EIS) information, for both anodes and cathodes. Moreover, it is believed that the adoption of LTO as a reference electrode could be of great significance for long-term monitoring of the charge and discharge behavior of individual electrodes in other kinds of lithium-ion cells. The Royal Society of Chemistry 2018-05-22 /pmc/articles/PMC9080700/ /pubmed/35541153 http://dx.doi.org/10.1039/c8ra03062f Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Yi, Shouzhong Wang, Bo Chen, Ziang Wang, Rui Wang, Dianlong A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes |
title | A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes |
title_full | A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes |
title_fullStr | A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes |
title_full_unstemmed | A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes |
title_short | A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes |
title_sort | study on lifepo(4)/graphite cells with built-in li(4)ti(5)o(12) reference electrodes |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9080700/ https://www.ncbi.nlm.nih.gov/pubmed/35541153 http://dx.doi.org/10.1039/c8ra03062f |
work_keys_str_mv | AT yishouzhong astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes AT wangbo astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes AT chenziang astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes AT wangrui astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes AT wangdianlong astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes AT yishouzhong studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes AT wangbo studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes AT chenziang studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes AT wangrui studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes AT wangdianlong studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes |