Cargando…

A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes

In this work, based on the superior electrochemical stability of Li(4)Ti(5)O(12) (LTO) electrodes, LiFePO(4) (LFP)/graphite cells with built-in LTO electrodes as reference electrodes were designed and fabricated. The characteristics of the LTO reference electrodes in the fabricated lithium-ion cells...

Descripción completa

Detalles Bibliográficos
Autores principales: Yi, Shouzhong, Wang, Bo, Chen, Ziang, Wang, Rui, Wang, Dianlong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9080700/
https://www.ncbi.nlm.nih.gov/pubmed/35541153
http://dx.doi.org/10.1039/c8ra03062f
_version_ 1784702847753912320
author Yi, Shouzhong
Wang, Bo
Chen, Ziang
Wang, Rui
Wang, Dianlong
author_facet Yi, Shouzhong
Wang, Bo
Chen, Ziang
Wang, Rui
Wang, Dianlong
author_sort Yi, Shouzhong
collection PubMed
description In this work, based on the superior electrochemical stability of Li(4)Ti(5)O(12) (LTO) electrodes, LiFePO(4) (LFP)/graphite cells with built-in LTO electrodes as reference electrodes were designed and fabricated. The characteristics of the LTO reference electrodes in the fabricated lithium-ion cells were measured and discussed. The experimental data demonstrated that the LTO built-in reference electrodes were simple to prepare and were feasible options for long-term in situ monitoring of the development of potentials and other electrochemical parameters, such as the Li(+) diffusion coefficient (D(Li)) and electrochemical impedance spectroscopy (EIS) information, for both anodes and cathodes. Moreover, it is believed that the adoption of LTO as a reference electrode could be of great significance for long-term monitoring of the charge and discharge behavior of individual electrodes in other kinds of lithium-ion cells.
format Online
Article
Text
id pubmed-9080700
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90807002022-05-09 A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes Yi, Shouzhong Wang, Bo Chen, Ziang Wang, Rui Wang, Dianlong RSC Adv Chemistry In this work, based on the superior electrochemical stability of Li(4)Ti(5)O(12) (LTO) electrodes, LiFePO(4) (LFP)/graphite cells with built-in LTO electrodes as reference electrodes were designed and fabricated. The characteristics of the LTO reference electrodes in the fabricated lithium-ion cells were measured and discussed. The experimental data demonstrated that the LTO built-in reference electrodes were simple to prepare and were feasible options for long-term in situ monitoring of the development of potentials and other electrochemical parameters, such as the Li(+) diffusion coefficient (D(Li)) and electrochemical impedance spectroscopy (EIS) information, for both anodes and cathodes. Moreover, it is believed that the adoption of LTO as a reference electrode could be of great significance for long-term monitoring of the charge and discharge behavior of individual electrodes in other kinds of lithium-ion cells. The Royal Society of Chemistry 2018-05-22 /pmc/articles/PMC9080700/ /pubmed/35541153 http://dx.doi.org/10.1039/c8ra03062f Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Yi, Shouzhong
Wang, Bo
Chen, Ziang
Wang, Rui
Wang, Dianlong
A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes
title A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes
title_full A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes
title_fullStr A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes
title_full_unstemmed A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes
title_short A study on LiFePO(4)/graphite cells with built-in Li(4)Ti(5)O(12) reference electrodes
title_sort study on lifepo(4)/graphite cells with built-in li(4)ti(5)o(12) reference electrodes
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9080700/
https://www.ncbi.nlm.nih.gov/pubmed/35541153
http://dx.doi.org/10.1039/c8ra03062f
work_keys_str_mv AT yishouzhong astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes
AT wangbo astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes
AT chenziang astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes
AT wangrui astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes
AT wangdianlong astudyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes
AT yishouzhong studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes
AT wangbo studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes
AT chenziang studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes
AT wangrui studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes
AT wangdianlong studyonlifepo4graphitecellswithbuiltinli4ti5o12referenceelectrodes