Cargando…

Usefulness of Real-Time Quantitative Microvascular Ultrasonography for Differentiation of Graves’ Disease from Destructive Thyroiditis in Thyrotoxic Patients

BACKGROUND: Microvascular ultrasonography (MVUS) is a third-generation Doppler technique that was developed to increase sensitivity compared to conventional Doppler. The purpose of this study was to compare MVUS with conventional color Doppler (CD) and power Doppler (PD) imaging to distinguish Grave...

Descripción completa

Detalles Bibliográficos
Autores principales: Baek, Han-Sang, Park, Ji-Yeon, Jeong, Chai-Ho, Ha, Jeonghoon, Kang, Moo Il, Lim, Dong-Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Endocrine Society 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9081314/
https://www.ncbi.nlm.nih.gov/pubmed/35413779
http://dx.doi.org/10.3803/EnM.2022.1413
_version_ 1784702957456982016
author Baek, Han-Sang
Park, Ji-Yeon
Jeong, Chai-Ho
Ha, Jeonghoon
Kang, Moo Il
Lim, Dong-Jun
author_facet Baek, Han-Sang
Park, Ji-Yeon
Jeong, Chai-Ho
Ha, Jeonghoon
Kang, Moo Il
Lim, Dong-Jun
author_sort Baek, Han-Sang
collection PubMed
description BACKGROUND: Microvascular ultrasonography (MVUS) is a third-generation Doppler technique that was developed to increase sensitivity compared to conventional Doppler. The purpose of this study was to compare MVUS with conventional color Doppler (CD) and power Doppler (PD) imaging to distinguish Graves’ disease (GD) from destructive thyroiditis (DT). METHODS: This prospective study included 101 subjects (46 GDs, 47 DTs, and eight normal controls) from October 2020 to November 2021. All ultrasonography examinations were performed using microvascular flow technology (MV-Flow). The CD, PD, and MVUS images were semi-quantitatively graded according to blood flow patterns. On the MVUS images, vascularity indices (VIs), which were the ratio (%) of color pixels in the total grayscale pixels in a defined region of interest, were obtained automatically. Receiver operating characteristic curve analysis was performed to verify the diagnostic performance of MVUS. The interclass correlation coefficient and Cohen’s kappa analysis were used to analyze the reliability of MVUS (ClinicalTrials.gov:NCT04879173). RESULTS: The area under the curve (AUC) for CD, PD, MVUS, and MVUS-VI was 0.822, 0.844, 0.808, and 0.852 respectively. The optimal cutoff value of the MVUS-VI was 24.95% for distinguishing GD and DT with 87% sensitivity and 80.9% specificity. We found a significant positive correlation of MVUS-VI with thyrotropin receptor antibody (r=0.554) and with thyroid stimulating immunoglobulin bioassay (r=0.841). MVUS showed high intra- and inter-observer reliability from various statistical method. CONCLUSION: In a real time and quantitative manner, MVUS-VI could be helpful to differentiate GD from thyroiditis in thyrotoxic patients, with less inter-observer variability.
format Online
Article
Text
id pubmed-9081314
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Endocrine Society
record_format MEDLINE/PubMed
spelling pubmed-90813142022-05-16 Usefulness of Real-Time Quantitative Microvascular Ultrasonography for Differentiation of Graves’ Disease from Destructive Thyroiditis in Thyrotoxic Patients Baek, Han-Sang Park, Ji-Yeon Jeong, Chai-Ho Ha, Jeonghoon Kang, Moo Il Lim, Dong-Jun Endocrinol Metab (Seoul) Original Article BACKGROUND: Microvascular ultrasonography (MVUS) is a third-generation Doppler technique that was developed to increase sensitivity compared to conventional Doppler. The purpose of this study was to compare MVUS with conventional color Doppler (CD) and power Doppler (PD) imaging to distinguish Graves’ disease (GD) from destructive thyroiditis (DT). METHODS: This prospective study included 101 subjects (46 GDs, 47 DTs, and eight normal controls) from October 2020 to November 2021. All ultrasonography examinations were performed using microvascular flow technology (MV-Flow). The CD, PD, and MVUS images were semi-quantitatively graded according to blood flow patterns. On the MVUS images, vascularity indices (VIs), which were the ratio (%) of color pixels in the total grayscale pixels in a defined region of interest, were obtained automatically. Receiver operating characteristic curve analysis was performed to verify the diagnostic performance of MVUS. The interclass correlation coefficient and Cohen’s kappa analysis were used to analyze the reliability of MVUS (ClinicalTrials.gov:NCT04879173). RESULTS: The area under the curve (AUC) for CD, PD, MVUS, and MVUS-VI was 0.822, 0.844, 0.808, and 0.852 respectively. The optimal cutoff value of the MVUS-VI was 24.95% for distinguishing GD and DT with 87% sensitivity and 80.9% specificity. We found a significant positive correlation of MVUS-VI with thyrotropin receptor antibody (r=0.554) and with thyroid stimulating immunoglobulin bioassay (r=0.841). MVUS showed high intra- and inter-observer reliability from various statistical method. CONCLUSION: In a real time and quantitative manner, MVUS-VI could be helpful to differentiate GD from thyroiditis in thyrotoxic patients, with less inter-observer variability. Korean Endocrine Society 2022-04 2022-04-13 /pmc/articles/PMC9081314/ /pubmed/35413779 http://dx.doi.org/10.3803/EnM.2022.1413 Text en Copyright © 2022 Korean Endocrine Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Baek, Han-Sang
Park, Ji-Yeon
Jeong, Chai-Ho
Ha, Jeonghoon
Kang, Moo Il
Lim, Dong-Jun
Usefulness of Real-Time Quantitative Microvascular Ultrasonography for Differentiation of Graves’ Disease from Destructive Thyroiditis in Thyrotoxic Patients
title Usefulness of Real-Time Quantitative Microvascular Ultrasonography for Differentiation of Graves’ Disease from Destructive Thyroiditis in Thyrotoxic Patients
title_full Usefulness of Real-Time Quantitative Microvascular Ultrasonography for Differentiation of Graves’ Disease from Destructive Thyroiditis in Thyrotoxic Patients
title_fullStr Usefulness of Real-Time Quantitative Microvascular Ultrasonography for Differentiation of Graves’ Disease from Destructive Thyroiditis in Thyrotoxic Patients
title_full_unstemmed Usefulness of Real-Time Quantitative Microvascular Ultrasonography for Differentiation of Graves’ Disease from Destructive Thyroiditis in Thyrotoxic Patients
title_short Usefulness of Real-Time Quantitative Microvascular Ultrasonography for Differentiation of Graves’ Disease from Destructive Thyroiditis in Thyrotoxic Patients
title_sort usefulness of real-time quantitative microvascular ultrasonography for differentiation of graves’ disease from destructive thyroiditis in thyrotoxic patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9081314/
https://www.ncbi.nlm.nih.gov/pubmed/35413779
http://dx.doi.org/10.3803/EnM.2022.1413
work_keys_str_mv AT baekhansang usefulnessofrealtimequantitativemicrovascularultrasonographyfordifferentiationofgravesdiseasefromdestructivethyroiditisinthyrotoxicpatients
AT parkjiyeon usefulnessofrealtimequantitativemicrovascularultrasonographyfordifferentiationofgravesdiseasefromdestructivethyroiditisinthyrotoxicpatients
AT jeongchaiho usefulnessofrealtimequantitativemicrovascularultrasonographyfordifferentiationofgravesdiseasefromdestructivethyroiditisinthyrotoxicpatients
AT hajeonghoon usefulnessofrealtimequantitativemicrovascularultrasonographyfordifferentiationofgravesdiseasefromdestructivethyroiditisinthyrotoxicpatients
AT kangmooil usefulnessofrealtimequantitativemicrovascularultrasonographyfordifferentiationofgravesdiseasefromdestructivethyroiditisinthyrotoxicpatients
AT limdongjun usefulnessofrealtimequantitativemicrovascularultrasonographyfordifferentiationofgravesdiseasefromdestructivethyroiditisinthyrotoxicpatients