Cargando…

Novel ionic polymer–metal composite actuator based on sulfonated poly(1,4-phenylene ether-ether-sulfone) and polyvinylidene fluoride/sulfonated graphene oxide

In the present work, sulfonated graphene oxide and sulfonated poly(1,4-phenylene ether-ether-sulfone) were blended with polyvinylidene fluoride to create a novel ionic polymer–metal composite actuator with enhanced performance. An ionic polymer–metal composite membrane in the protonated form was pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Khan, Ajahar, Jain, Ravi Kant, Ghosh, Bhaskar, Inamuddin, Asiri, Abdullah M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9082661/
https://www.ncbi.nlm.nih.gov/pubmed/35539767
http://dx.doi.org/10.1039/c8ra03554g
_version_ 1784703252266221568
author Khan, Ajahar
Jain, Ravi Kant
Ghosh, Bhaskar
Inamuddin,
Asiri, Abdullah M.
author_facet Khan, Ajahar
Jain, Ravi Kant
Ghosh, Bhaskar
Inamuddin,
Asiri, Abdullah M.
author_sort Khan, Ajahar
collection PubMed
description In the present work, sulfonated graphene oxide and sulfonated poly(1,4-phenylene ether-ether-sulfone) were blended with polyvinylidene fluoride to create a novel ionic polymer–metal composite actuator with enhanced performance. An ionic polymer–metal composite membrane in the protonated form was prepared by casting a composite blend of sulfonated poly(1,4-phenylene ether-ether-sulfone), polyvinylidene fluoride and sulfonated graphene oxide onto a plating of platinum metal as the electrode. The degree of sulfonation of poly(1,4-phenylene ether-ether-sulfone) was characterized using ion-exchange capacity measurements. Energy dispersive X-ray and transmittance electron microscopy analyses were carried out to analyze the chemical composition and detailed structure. Deposition of the platinum electrode and the surface morphology of the proposed ionic polymer–metal composite actuator were assessed using scanning electron microscopy analysis. The electrical properties were measured using cyclic voltammetry, linear sweep voltammetry and proton conductivity. These measurements confirmed the better actuation performance of the fabricated ionic polymer–metal composite actuator compared to other expensive ionic polymer-based actuators, in terms of its high ion-exchange capacity, good proton conductivity, high current density and large bending deflection. The robust, flexible and mechanically strong membrane actuator, fabricated via the synergistic combination of sulfonated poly(1,4-phenylene ether-ether-sulfone), polyvinylidene fluoride and sulfonated graphene oxide, has considerable potential as an actuator material for robotic, bio-mimetic and other applications.
format Online
Article
Text
id pubmed-9082661
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90826612022-05-09 Novel ionic polymer–metal composite actuator based on sulfonated poly(1,4-phenylene ether-ether-sulfone) and polyvinylidene fluoride/sulfonated graphene oxide Khan, Ajahar Jain, Ravi Kant Ghosh, Bhaskar Inamuddin, Asiri, Abdullah M. RSC Adv Chemistry In the present work, sulfonated graphene oxide and sulfonated poly(1,4-phenylene ether-ether-sulfone) were blended with polyvinylidene fluoride to create a novel ionic polymer–metal composite actuator with enhanced performance. An ionic polymer–metal composite membrane in the protonated form was prepared by casting a composite blend of sulfonated poly(1,4-phenylene ether-ether-sulfone), polyvinylidene fluoride and sulfonated graphene oxide onto a plating of platinum metal as the electrode. The degree of sulfonation of poly(1,4-phenylene ether-ether-sulfone) was characterized using ion-exchange capacity measurements. Energy dispersive X-ray and transmittance electron microscopy analyses were carried out to analyze the chemical composition and detailed structure. Deposition of the platinum electrode and the surface morphology of the proposed ionic polymer–metal composite actuator were assessed using scanning electron microscopy analysis. The electrical properties were measured using cyclic voltammetry, linear sweep voltammetry and proton conductivity. These measurements confirmed the better actuation performance of the fabricated ionic polymer–metal composite actuator compared to other expensive ionic polymer-based actuators, in terms of its high ion-exchange capacity, good proton conductivity, high current density and large bending deflection. The robust, flexible and mechanically strong membrane actuator, fabricated via the synergistic combination of sulfonated poly(1,4-phenylene ether-ether-sulfone), polyvinylidene fluoride and sulfonated graphene oxide, has considerable potential as an actuator material for robotic, bio-mimetic and other applications. The Royal Society of Chemistry 2018-07-16 /pmc/articles/PMC9082661/ /pubmed/35539767 http://dx.doi.org/10.1039/c8ra03554g Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Khan, Ajahar
Jain, Ravi Kant
Ghosh, Bhaskar
Inamuddin,
Asiri, Abdullah M.
Novel ionic polymer–metal composite actuator based on sulfonated poly(1,4-phenylene ether-ether-sulfone) and polyvinylidene fluoride/sulfonated graphene oxide
title Novel ionic polymer–metal composite actuator based on sulfonated poly(1,4-phenylene ether-ether-sulfone) and polyvinylidene fluoride/sulfonated graphene oxide
title_full Novel ionic polymer–metal composite actuator based on sulfonated poly(1,4-phenylene ether-ether-sulfone) and polyvinylidene fluoride/sulfonated graphene oxide
title_fullStr Novel ionic polymer–metal composite actuator based on sulfonated poly(1,4-phenylene ether-ether-sulfone) and polyvinylidene fluoride/sulfonated graphene oxide
title_full_unstemmed Novel ionic polymer–metal composite actuator based on sulfonated poly(1,4-phenylene ether-ether-sulfone) and polyvinylidene fluoride/sulfonated graphene oxide
title_short Novel ionic polymer–metal composite actuator based on sulfonated poly(1,4-phenylene ether-ether-sulfone) and polyvinylidene fluoride/sulfonated graphene oxide
title_sort novel ionic polymer–metal composite actuator based on sulfonated poly(1,4-phenylene ether-ether-sulfone) and polyvinylidene fluoride/sulfonated graphene oxide
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9082661/
https://www.ncbi.nlm.nih.gov/pubmed/35539767
http://dx.doi.org/10.1039/c8ra03554g
work_keys_str_mv AT khanajahar novelionicpolymermetalcompositeactuatorbasedonsulfonatedpoly14phenyleneetherethersulfoneandpolyvinylidenefluoridesulfonatedgrapheneoxide
AT jainravikant novelionicpolymermetalcompositeactuatorbasedonsulfonatedpoly14phenyleneetherethersulfoneandpolyvinylidenefluoridesulfonatedgrapheneoxide
AT ghoshbhaskar novelionicpolymermetalcompositeactuatorbasedonsulfonatedpoly14phenyleneetherethersulfoneandpolyvinylidenefluoridesulfonatedgrapheneoxide
AT inamuddin novelionicpolymermetalcompositeactuatorbasedonsulfonatedpoly14phenyleneetherethersulfoneandpolyvinylidenefluoridesulfonatedgrapheneoxide
AT asiriabdullahm novelionicpolymermetalcompositeactuatorbasedonsulfonatedpoly14phenyleneetherethersulfoneandpolyvinylidenefluoridesulfonatedgrapheneoxide