Robustness Assessment of Images From a 0.35T Scanner of an Integrated MRI-Linac: Characterization of Radiomics Features in Phantom and Patient Data
Purpose: Radiomics entails the extraction of quantitative imaging biomarkers (or radiomics features) hypothesized to provide additional pathophysiological and/or clinical information compared to qualitative visual observation and interpretation. This retrospective study explores the variability of r...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9083059/ https://www.ncbi.nlm.nih.gov/pubmed/35521966 http://dx.doi.org/10.1177/15330338221099113 |
_version_ | 1784703338379476992 |
---|---|
author | Ericsson-Szecsenyi, Rebecka Zhang, Geoffrey Redler, Gage Feygelman, Vladimir Rosenberg, Stephen Latifi, Kujtim Ceberg, Crister Moros, Eduardo G. |
author_facet | Ericsson-Szecsenyi, Rebecka Zhang, Geoffrey Redler, Gage Feygelman, Vladimir Rosenberg, Stephen Latifi, Kujtim Ceberg, Crister Moros, Eduardo G. |
author_sort | Ericsson-Szecsenyi, Rebecka |
collection | PubMed |
description | Purpose: Radiomics entails the extraction of quantitative imaging biomarkers (or radiomics features) hypothesized to provide additional pathophysiological and/or clinical information compared to qualitative visual observation and interpretation. This retrospective study explores the variability of radiomics features extracted from images acquired with the 0.35 T scanner of an integrated MRI-Linac. We hypothesized we would be able to identify features with high repeatability and reproducibility over various imaging conditions using phantom and patient imaging studies. We also compared findings from the literature relevant to our results. Methods: Eleven scans of a Magphan(®) RT phantom over 13 months and 11 scans of a ViewRay Daily QA phantom over 11 days constituted the phantom data. Patient datasets included 50 images from ten anonymized stereotactic body radiation therapy (SBRT) pancreatic cancer patients (50 Gy in 5 fractions). A True Fast Imaging with Steady-State Free Precession (TRUFI) pulse sequence was selected, using a voxel resolution of 1.5 mm × 1.5 mm × 1.5 mm and 1.5 mm × 1.5 mm × 3.0 mm for phantom and patient data, respectively. A total of 1087 shape-based, first, second, and higher order features were extracted followed by robustness analysis. Robustness was assessed with the Coefficient of Variation (CoV < 5%). Results: We identified 130 robust features across the datasets. Robust features were found within each category, except for 2 second-order sub-groups, namely, Gray Level Size Zone Matrix (GLSZM) and Neighborhood Gray Tone Difference Matrix (NGTDM). Additionally, several robust features agreed with findings from other stability assessments or predictive performance studies in the literature. Conclusion: We verified the stability of the 0.35 T scanner of an integrated MRI-Linac for longitudinal radiomics phantom studies and identified robust features over various imaging conditions. We conclude that phantom measurements can be used to identify robust radiomics features. More stability assessment research is warranted. |
format | Online Article Text |
id | pubmed-9083059 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-90830592022-05-10 Robustness Assessment of Images From a 0.35T Scanner of an Integrated MRI-Linac: Characterization of Radiomics Features in Phantom and Patient Data Ericsson-Szecsenyi, Rebecka Zhang, Geoffrey Redler, Gage Feygelman, Vladimir Rosenberg, Stephen Latifi, Kujtim Ceberg, Crister Moros, Eduardo G. Technol Cancer Res Treat Original Article Purpose: Radiomics entails the extraction of quantitative imaging biomarkers (or radiomics features) hypothesized to provide additional pathophysiological and/or clinical information compared to qualitative visual observation and interpretation. This retrospective study explores the variability of radiomics features extracted from images acquired with the 0.35 T scanner of an integrated MRI-Linac. We hypothesized we would be able to identify features with high repeatability and reproducibility over various imaging conditions using phantom and patient imaging studies. We also compared findings from the literature relevant to our results. Methods: Eleven scans of a Magphan(®) RT phantom over 13 months and 11 scans of a ViewRay Daily QA phantom over 11 days constituted the phantom data. Patient datasets included 50 images from ten anonymized stereotactic body radiation therapy (SBRT) pancreatic cancer patients (50 Gy in 5 fractions). A True Fast Imaging with Steady-State Free Precession (TRUFI) pulse sequence was selected, using a voxel resolution of 1.5 mm × 1.5 mm × 1.5 mm and 1.5 mm × 1.5 mm × 3.0 mm for phantom and patient data, respectively. A total of 1087 shape-based, first, second, and higher order features were extracted followed by robustness analysis. Robustness was assessed with the Coefficient of Variation (CoV < 5%). Results: We identified 130 robust features across the datasets. Robust features were found within each category, except for 2 second-order sub-groups, namely, Gray Level Size Zone Matrix (GLSZM) and Neighborhood Gray Tone Difference Matrix (NGTDM). Additionally, several robust features agreed with findings from other stability assessments or predictive performance studies in the literature. Conclusion: We verified the stability of the 0.35 T scanner of an integrated MRI-Linac for longitudinal radiomics phantom studies and identified robust features over various imaging conditions. We conclude that phantom measurements can be used to identify robust radiomics features. More stability assessment research is warranted. SAGE Publications 2022-05-06 /pmc/articles/PMC9083059/ /pubmed/35521966 http://dx.doi.org/10.1177/15330338221099113 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Ericsson-Szecsenyi, Rebecka Zhang, Geoffrey Redler, Gage Feygelman, Vladimir Rosenberg, Stephen Latifi, Kujtim Ceberg, Crister Moros, Eduardo G. Robustness Assessment of Images From a 0.35T Scanner of an Integrated MRI-Linac: Characterization of Radiomics Features in Phantom and Patient Data |
title | Robustness Assessment of Images From a 0.35T Scanner of an Integrated MRI-Linac: Characterization of Radiomics Features in Phantom and Patient Data |
title_full | Robustness Assessment of Images From a 0.35T Scanner of an Integrated MRI-Linac: Characterization of Radiomics Features in Phantom and Patient Data |
title_fullStr | Robustness Assessment of Images From a 0.35T Scanner of an Integrated MRI-Linac: Characterization of Radiomics Features in Phantom and Patient Data |
title_full_unstemmed | Robustness Assessment of Images From a 0.35T Scanner of an Integrated MRI-Linac: Characterization of Radiomics Features in Phantom and Patient Data |
title_short | Robustness Assessment of Images From a 0.35T Scanner of an Integrated MRI-Linac: Characterization of Radiomics Features in Phantom and Patient Data |
title_sort | robustness assessment of images from a 0.35t scanner of an integrated mri-linac: characterization of radiomics features in phantom and patient data |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9083059/ https://www.ncbi.nlm.nih.gov/pubmed/35521966 http://dx.doi.org/10.1177/15330338221099113 |
work_keys_str_mv | AT ericssonszecsenyirebecka robustnessassessmentofimagesfroma035tscannerofanintegratedmrilinaccharacterizationofradiomicsfeaturesinphantomandpatientdata AT zhanggeoffrey robustnessassessmentofimagesfroma035tscannerofanintegratedmrilinaccharacterizationofradiomicsfeaturesinphantomandpatientdata AT redlergage robustnessassessmentofimagesfroma035tscannerofanintegratedmrilinaccharacterizationofradiomicsfeaturesinphantomandpatientdata AT feygelmanvladimir robustnessassessmentofimagesfroma035tscannerofanintegratedmrilinaccharacterizationofradiomicsfeaturesinphantomandpatientdata AT rosenbergstephen robustnessassessmentofimagesfroma035tscannerofanintegratedmrilinaccharacterizationofradiomicsfeaturesinphantomandpatientdata AT latifikujtim robustnessassessmentofimagesfroma035tscannerofanintegratedmrilinaccharacterizationofradiomicsfeaturesinphantomandpatientdata AT cebergcrister robustnessassessmentofimagesfroma035tscannerofanintegratedmrilinaccharacterizationofradiomicsfeaturesinphantomandpatientdata AT moroseduardog robustnessassessmentofimagesfroma035tscannerofanintegratedmrilinaccharacterizationofradiomicsfeaturesinphantomandpatientdata |