Cargando…

Changes in Noncontact Meibography and Noninvasive Tear Break-Up Time Test with Contact Lenses Usage

PURPOSE: The study aimed to determine changes detected by noncontact meibography and noninvasive break-up time test (NIBUT) in individuals with regular use of soft contact lenses and compare these findings with irregular soft contact lenses wearers who not compliant with them and non-wearers control...

Descripción completa

Detalles Bibliográficos
Autores principales: Fattoh, Reham, Mounir, Amr, Anbar, Mohamed, Mohammed, Osama Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9084505/
https://www.ncbi.nlm.nih.gov/pubmed/35547400
http://dx.doi.org/10.2147/OPTH.S362307
_version_ 1784703625599123456
author Fattoh, Reham
Mounir, Amr
Anbar, Mohamed
Mohammed, Osama Ali
author_facet Fattoh, Reham
Mounir, Amr
Anbar, Mohamed
Mohammed, Osama Ali
author_sort Fattoh, Reham
collection PubMed
description PURPOSE: The study aimed to determine changes detected by noncontact meibography and noninvasive break-up time test (NIBUT) in individuals with regular use of soft contact lenses and compare these findings with irregular soft contact lenses wearers who not compliant with them and non-wearers control group. PATIENTS AND METHODS: A prospective nonrandomized case-control study in which individuals were recruited and distributed into three groups: Group A (regular contact lens wearers), group B (irregular contact lens wearers), and group C (non-wearers). Ocular Surface Disease Index (OSDI) was obtained. Noncontact meibography and noninvasive tear break-up time were measured without lenses on using Sirius(®) Scheimpflug Camera. RESULTS: One hundred sixty-six eyes of 83 individuals were included; 36 eyes in group A, 50 eyes in group B, and 80 eyes in group C. The mean total meiboscore was 1.99, 1.61, and 1.28, respectively. The mean meibograde was 3.03, 2.86, and 1.99, respectively. Noninvasive break-up time (NIF-BUT) was 8.42, 11.76, and 13.57 seconds, respectively. CONCLUSION: There is a difference in OSDI score, meibomian score, and break-up time between different study groups. The study results show that there are trends in lens wearers and non-lens wearers. This is useful for the field to understand the differences between lens wearers and non-lens wearers.
format Online
Article
Text
id pubmed-9084505
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-90845052022-05-10 Changes in Noncontact Meibography and Noninvasive Tear Break-Up Time Test with Contact Lenses Usage Fattoh, Reham Mounir, Amr Anbar, Mohamed Mohammed, Osama Ali Clin Ophthalmol Original Research PURPOSE: The study aimed to determine changes detected by noncontact meibography and noninvasive break-up time test (NIBUT) in individuals with regular use of soft contact lenses and compare these findings with irregular soft contact lenses wearers who not compliant with them and non-wearers control group. PATIENTS AND METHODS: A prospective nonrandomized case-control study in which individuals were recruited and distributed into three groups: Group A (regular contact lens wearers), group B (irregular contact lens wearers), and group C (non-wearers). Ocular Surface Disease Index (OSDI) was obtained. Noncontact meibography and noninvasive tear break-up time were measured without lenses on using Sirius(®) Scheimpflug Camera. RESULTS: One hundred sixty-six eyes of 83 individuals were included; 36 eyes in group A, 50 eyes in group B, and 80 eyes in group C. The mean total meiboscore was 1.99, 1.61, and 1.28, respectively. The mean meibograde was 3.03, 2.86, and 1.99, respectively. Noninvasive break-up time (NIF-BUT) was 8.42, 11.76, and 13.57 seconds, respectively. CONCLUSION: There is a difference in OSDI score, meibomian score, and break-up time between different study groups. The study results show that there are trends in lens wearers and non-lens wearers. This is useful for the field to understand the differences between lens wearers and non-lens wearers. Dove 2022-05-05 /pmc/articles/PMC9084505/ /pubmed/35547400 http://dx.doi.org/10.2147/OPTH.S362307 Text en © 2022 Fattoh et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Fattoh, Reham
Mounir, Amr
Anbar, Mohamed
Mohammed, Osama Ali
Changes in Noncontact Meibography and Noninvasive Tear Break-Up Time Test with Contact Lenses Usage
title Changes in Noncontact Meibography and Noninvasive Tear Break-Up Time Test with Contact Lenses Usage
title_full Changes in Noncontact Meibography and Noninvasive Tear Break-Up Time Test with Contact Lenses Usage
title_fullStr Changes in Noncontact Meibography and Noninvasive Tear Break-Up Time Test with Contact Lenses Usage
title_full_unstemmed Changes in Noncontact Meibography and Noninvasive Tear Break-Up Time Test with Contact Lenses Usage
title_short Changes in Noncontact Meibography and Noninvasive Tear Break-Up Time Test with Contact Lenses Usage
title_sort changes in noncontact meibography and noninvasive tear break-up time test with contact lenses usage
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9084505/
https://www.ncbi.nlm.nih.gov/pubmed/35547400
http://dx.doi.org/10.2147/OPTH.S362307
work_keys_str_mv AT fattohreham changesinnoncontactmeibographyandnoninvasivetearbreakuptimetestwithcontactlensesusage
AT mouniramr changesinnoncontactmeibographyandnoninvasivetearbreakuptimetestwithcontactlensesusage
AT anbarmohamed changesinnoncontactmeibographyandnoninvasivetearbreakuptimetestwithcontactlensesusage
AT mohammedosamaali changesinnoncontactmeibographyandnoninvasivetearbreakuptimetestwithcontactlensesusage