Cargando…
Monte Carlo Dose Calculation – A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions
To provide accurate and fast 3-D dose verification for hypofractionated stereotactic radiotherapy (SRT/SBRT) of small and multi targets calculated with a Varian Eclipse treatment planning system (TPS) delivered on a Varian accelerator. Ten brain and lung hypofractionated SRT/SBRT linac-based and Cyb...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9084579/ https://www.ncbi.nlm.nih.gov/pubmed/35548031 http://dx.doi.org/10.4103/jmp.jmp_123_21 |
_version_ | 1784703639560912896 |
---|---|
author | Lin, Teh Wang, Lu Charlie Ma, C-M |
author_facet | Lin, Teh Wang, Lu Charlie Ma, C-M |
author_sort | Lin, Teh |
collection | PubMed |
description | To provide accurate and fast 3-D dose verification for hypofractionated stereotactic radiotherapy (SRT/SBRT) of small and multi targets calculated with a Varian Eclipse treatment planning system (TPS) delivered on a Varian accelerator. Ten brain and lung hypofractionated SRT/SBRT linac-based and CyberKnife plans were generated by the Eclipse system for delivery on the accelerator with the Millenium-120 leaf multileaf collimator (MLC) and Multiplan for the CyberKnife machine. These clinical SRT/SBRT plans required accurate quality assurance measurements to obtain absolute point dose and 3-D dose distributions due to the low number of fractions and high fraction doses. For small-field and multi-target plans, the EGS4/MCSIM code was used to calculate the dose distribution. A 0.125 cc ion chamber, a 0.016 cc pin-point chamber and Kodak EDR2 film were used for the measurements and the results were compared with Monte Carlo (MC) calculations. The dosimetry for small-field and multi-target treatment plans is challenging due to the comparable range of secondary electrons and the field sizes defined by SRT/SBRT MLC segments. Our MC simulations can accurately reproduce the linac dose distributions (within 1%/1 mm) three dimensionally. For the clinical SRT/SBRT plans investigated in this work, the MC doses agreed within 3% with ion chamber measurements and within 2%/2 mm with film measurements. The doses calculated by the Eclipse AAA algorithm and Multiplan differed by no more than 5% from MC calculations for small (4–40 cc) Planning Target Volumes (PTVs). MC dose calculation provides accurate and fast 3-D dose verification for hypofractionated SRT for small and multi-target treatment plans generated by a Varian Eclipse TPS on a Varian accelerator and Multiplan treatment planning on the CyberKnife System. |
format | Online Article Text |
id | pubmed-9084579 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-90845792022-05-10 Monte Carlo Dose Calculation – A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions Lin, Teh Wang, Lu Charlie Ma, C-M J Med Phys Technical Note To provide accurate and fast 3-D dose verification for hypofractionated stereotactic radiotherapy (SRT/SBRT) of small and multi targets calculated with a Varian Eclipse treatment planning system (TPS) delivered on a Varian accelerator. Ten brain and lung hypofractionated SRT/SBRT linac-based and CyberKnife plans were generated by the Eclipse system for delivery on the accelerator with the Millenium-120 leaf multileaf collimator (MLC) and Multiplan for the CyberKnife machine. These clinical SRT/SBRT plans required accurate quality assurance measurements to obtain absolute point dose and 3-D dose distributions due to the low number of fractions and high fraction doses. For small-field and multi-target plans, the EGS4/MCSIM code was used to calculate the dose distribution. A 0.125 cc ion chamber, a 0.016 cc pin-point chamber and Kodak EDR2 film were used for the measurements and the results were compared with Monte Carlo (MC) calculations. The dosimetry for small-field and multi-target treatment plans is challenging due to the comparable range of secondary electrons and the field sizes defined by SRT/SBRT MLC segments. Our MC simulations can accurately reproduce the linac dose distributions (within 1%/1 mm) three dimensionally. For the clinical SRT/SBRT plans investigated in this work, the MC doses agreed within 3% with ion chamber measurements and within 2%/2 mm with film measurements. The doses calculated by the Eclipse AAA algorithm and Multiplan differed by no more than 5% from MC calculations for small (4–40 cc) Planning Target Volumes (PTVs). MC dose calculation provides accurate and fast 3-D dose verification for hypofractionated SRT for small and multi-target treatment plans generated by a Varian Eclipse TPS on a Varian accelerator and Multiplan treatment planning on the CyberKnife System. Wolters Kluwer - Medknow 2022 2022-03-31 /pmc/articles/PMC9084579/ /pubmed/35548031 http://dx.doi.org/10.4103/jmp.jmp_123_21 Text en Copyright: © 2022 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Technical Note Lin, Teh Wang, Lu Charlie Ma, C-M Monte Carlo Dose Calculation – A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions |
title | Monte Carlo Dose Calculation – A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions |
title_full | Monte Carlo Dose Calculation – A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions |
title_fullStr | Monte Carlo Dose Calculation – A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions |
title_full_unstemmed | Monte Carlo Dose Calculation – A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions |
title_short | Monte Carlo Dose Calculation – A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions |
title_sort | monte carlo dose calculation – a qa method for srt and sbrt plans in treating multiple and small metastatic lesions |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9084579/ https://www.ncbi.nlm.nih.gov/pubmed/35548031 http://dx.doi.org/10.4103/jmp.jmp_123_21 |
work_keys_str_mv | AT linteh montecarlodosecalculationaqamethodforsrtandsbrtplansintreatingmultipleandsmallmetastaticlesions AT wanglu montecarlodosecalculationaqamethodforsrtandsbrtplansintreatingmultipleandsmallmetastaticlesions AT charliemacm montecarlodosecalculationaqamethodforsrtandsbrtplansintreatingmultipleandsmallmetastaticlesions |