Embryo/Fetus Doses from (18)F-Fludeoxyglucose Radiopharmaceutical in Positron Emission Tomography/ Computed Tomography

AIM: The embryo/fetus may be accidentally exposed to ionizing radiation. The aim of this study is to calculate embryo/fetus doses in pregnant women who underwent F-18 fludeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) scan. MATERIALS AND METHODS: Between June 2015 and Ju...

Descripción completa

Detalles Bibliográficos
Autores principales: Işıkçı, Nazenin İpek, Demir, Mustafa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9084586/
https://www.ncbi.nlm.nih.gov/pubmed/35548038
http://dx.doi.org/10.4103/jmp.jmp_115_21
_version_ 1784703641312034816
author Işıkçı, Nazenin İpek
Demir, Mustafa
author_facet Işıkçı, Nazenin İpek
Demir, Mustafa
author_sort Işıkçı, Nazenin İpek
collection PubMed
description AIM: The embryo/fetus may be accidentally exposed to ionizing radiation. The aim of this study is to calculate embryo/fetus doses in pregnant women who underwent F-18 fludeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) scan. MATERIALS AND METHODS: Between June 2015 and June 2021, 15 pregnant women underwent F-18 FDG PET/CT applied to the Genetic Research Center (GETAM). The OLINDA/EXM package program was used for internal radiation dosimetry according to the Medical Internal Radiation Dose scheme. FetDose V4 computer software was used to compute the embryo/fetus absorbed dose from CT scan. RESULTS: The amount of the injected F-18 FDG activity to patients varied between 333 and 555 MBq. The mean embryo/fetal dose from F-18 FDG was 7.2 ± 2.8 mGy. In addition, the CT component dose to the embryo/fetus dose ranged from 8.5 to 16 mGy with a mean of 12.14 ± 2.05. CONCLUSIONS: The embryo/fetus dose from F-18 FDG PET/CT was <15 mGy, however, questioning the women's childbearing prior to scintigraphy is the first-line strategy to avoid accidental radiation exposure and stochastic risks.
format Online
Article
Text
id pubmed-9084586
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-90845862022-05-10 Embryo/Fetus Doses from (18)F-Fludeoxyglucose Radiopharmaceutical in Positron Emission Tomography/ Computed Tomography Işıkçı, Nazenin İpek Demir, Mustafa J Med Phys Technical Note AIM: The embryo/fetus may be accidentally exposed to ionizing radiation. The aim of this study is to calculate embryo/fetus doses in pregnant women who underwent F-18 fludeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) scan. MATERIALS AND METHODS: Between June 2015 and June 2021, 15 pregnant women underwent F-18 FDG PET/CT applied to the Genetic Research Center (GETAM). The OLINDA/EXM package program was used for internal radiation dosimetry according to the Medical Internal Radiation Dose scheme. FetDose V4 computer software was used to compute the embryo/fetus absorbed dose from CT scan. RESULTS: The amount of the injected F-18 FDG activity to patients varied between 333 and 555 MBq. The mean embryo/fetal dose from F-18 FDG was 7.2 ± 2.8 mGy. In addition, the CT component dose to the embryo/fetus dose ranged from 8.5 to 16 mGy with a mean of 12.14 ± 2.05. CONCLUSIONS: The embryo/fetus dose from F-18 FDG PET/CT was <15 mGy, however, questioning the women's childbearing prior to scintigraphy is the first-line strategy to avoid accidental radiation exposure and stochastic risks. Wolters Kluwer - Medknow 2022 2022-03-31 /pmc/articles/PMC9084586/ /pubmed/35548038 http://dx.doi.org/10.4103/jmp.jmp_115_21 Text en Copyright: © 2022 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Technical Note
Işıkçı, Nazenin İpek
Demir, Mustafa
Embryo/Fetus Doses from (18)F-Fludeoxyglucose Radiopharmaceutical in Positron Emission Tomography/ Computed Tomography
title Embryo/Fetus Doses from (18)F-Fludeoxyglucose Radiopharmaceutical in Positron Emission Tomography/ Computed Tomography
title_full Embryo/Fetus Doses from (18)F-Fludeoxyglucose Radiopharmaceutical in Positron Emission Tomography/ Computed Tomography
title_fullStr Embryo/Fetus Doses from (18)F-Fludeoxyglucose Radiopharmaceutical in Positron Emission Tomography/ Computed Tomography
title_full_unstemmed Embryo/Fetus Doses from (18)F-Fludeoxyglucose Radiopharmaceutical in Positron Emission Tomography/ Computed Tomography
title_short Embryo/Fetus Doses from (18)F-Fludeoxyglucose Radiopharmaceutical in Positron Emission Tomography/ Computed Tomography
title_sort embryo/fetus doses from (18)f-fludeoxyglucose radiopharmaceutical in positron emission tomography/ computed tomography
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9084586/
https://www.ncbi.nlm.nih.gov/pubmed/35548038
http://dx.doi.org/10.4103/jmp.jmp_115_21
work_keys_str_mv AT isıkcınazeninipek embryofetusdosesfrom18ffludeoxyglucoseradiopharmaceuticalinpositronemissiontomographycomputedtomography
AT demirmustafa embryofetusdosesfrom18ffludeoxyglucoseradiopharmaceuticalinpositronemissiontomographycomputedtomography