Cargando…
Magnet-Guided Bionic System with LIFU Responsiveness and Natural Thrombus Tropism for Enhanced Thrombus-Targeting Ability
BACKGROUND: Arterial thrombosis is a serious threat to human health. Recently, many thrombus-targeted nanoparticles (NPs) have been constructed for detecting thrombi or monitoring thrombolysis, but their thrombus-targeting performance is limited. Considering this drawback, we designed a specific bio...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9087377/ https://www.ncbi.nlm.nih.gov/pubmed/35558339 http://dx.doi.org/10.2147/IJN.S357050 |
_version_ | 1784704191371935744 |
---|---|
author | Fang, Ni Liu, Jia Hou, Jingxin Zhong, Yixin Luo, Ying Hu, Liu Zhang, Wenli Wang, Junrui Xu, Jie Zhou, Jun Zhang, Yu Ran, Haitao Guo, Dajing |
author_facet | Fang, Ni Liu, Jia Hou, Jingxin Zhong, Yixin Luo, Ying Hu, Liu Zhang, Wenli Wang, Junrui Xu, Jie Zhou, Jun Zhang, Yu Ran, Haitao Guo, Dajing |
author_sort | Fang, Ni |
collection | PubMed |
description | BACKGROUND: Arterial thrombosis is a serious threat to human health. Recently, many thrombus-targeted nanoparticles (NPs) have been constructed for detecting thrombi or monitoring thrombolysis, but their thrombus-targeting performance is limited. Considering this drawback, we designed a specific bionic system with enhanced thrombus-targeting ability. MATERIALS AND METHODS: In the bionic system, gelatin was chosen as a carrier, and Fe(3)O(4) served as a magnetic navigation medium and a magnetic resonance (MR) imaging agent. The CREKA peptide, which targets fibrin, was conjugated to the surface of gelatin to prepare targeted NPs (TNPs), which were then engulfed by macrophages to construct the bionic system. At the targeted site, the bionic system released its interior TNPs under low-intensity focused ultrasound (LIFU) irradiation. Moreover, the targeting performance was further improved by the conjugated CREKA peptide. RESULTS: In this study, we successfully constructed a bionic system and demonstrated its targeting ability in vitro and in vivo. The results indicated that most TNPs were released from macrophages under LIFU irradiation at 2 W/cm(2) for 10 min in vitro. Additionally, the enhanced thrombus-targeting ability, based on the natural tropism of macrophages toward inflammatory thrombi, magnetic navigation and the CREKA peptide, was verified ex vivo and in vivo. Moreover, compared with the bionic system group, the group treated with TNPs had significantly decreased liver and spleen signals in MR images and significantly enhanced liver and spleen signals in fluorescence images, indicating that the bionic system is less likely to be cleared by the reticuloendothelial system (RES) than TNPs, which may promote the accumulation of the bionic system at the site of the thrombus. CONCLUSION: These results suggest that the magnet-guided bionic system with LIFU responsiveness is an excellent candidate for targeting thrombi and holds promise as an innovative drug delivery system for thrombolytic therapy. |
format | Online Article Text |
id | pubmed-9087377 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-90873772022-05-11 Magnet-Guided Bionic System with LIFU Responsiveness and Natural Thrombus Tropism for Enhanced Thrombus-Targeting Ability Fang, Ni Liu, Jia Hou, Jingxin Zhong, Yixin Luo, Ying Hu, Liu Zhang, Wenli Wang, Junrui Xu, Jie Zhou, Jun Zhang, Yu Ran, Haitao Guo, Dajing Int J Nanomedicine Original Research BACKGROUND: Arterial thrombosis is a serious threat to human health. Recently, many thrombus-targeted nanoparticles (NPs) have been constructed for detecting thrombi or monitoring thrombolysis, but their thrombus-targeting performance is limited. Considering this drawback, we designed a specific bionic system with enhanced thrombus-targeting ability. MATERIALS AND METHODS: In the bionic system, gelatin was chosen as a carrier, and Fe(3)O(4) served as a magnetic navigation medium and a magnetic resonance (MR) imaging agent. The CREKA peptide, which targets fibrin, was conjugated to the surface of gelatin to prepare targeted NPs (TNPs), which were then engulfed by macrophages to construct the bionic system. At the targeted site, the bionic system released its interior TNPs under low-intensity focused ultrasound (LIFU) irradiation. Moreover, the targeting performance was further improved by the conjugated CREKA peptide. RESULTS: In this study, we successfully constructed a bionic system and demonstrated its targeting ability in vitro and in vivo. The results indicated that most TNPs were released from macrophages under LIFU irradiation at 2 W/cm(2) for 10 min in vitro. Additionally, the enhanced thrombus-targeting ability, based on the natural tropism of macrophages toward inflammatory thrombi, magnetic navigation and the CREKA peptide, was verified ex vivo and in vivo. Moreover, compared with the bionic system group, the group treated with TNPs had significantly decreased liver and spleen signals in MR images and significantly enhanced liver and spleen signals in fluorescence images, indicating that the bionic system is less likely to be cleared by the reticuloendothelial system (RES) than TNPs, which may promote the accumulation of the bionic system at the site of the thrombus. CONCLUSION: These results suggest that the magnet-guided bionic system with LIFU responsiveness is an excellent candidate for targeting thrombi and holds promise as an innovative drug delivery system for thrombolytic therapy. Dove 2022-05-04 /pmc/articles/PMC9087377/ /pubmed/35558339 http://dx.doi.org/10.2147/IJN.S357050 Text en © 2022 Fang et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Fang, Ni Liu, Jia Hou, Jingxin Zhong, Yixin Luo, Ying Hu, Liu Zhang, Wenli Wang, Junrui Xu, Jie Zhou, Jun Zhang, Yu Ran, Haitao Guo, Dajing Magnet-Guided Bionic System with LIFU Responsiveness and Natural Thrombus Tropism for Enhanced Thrombus-Targeting Ability |
title | Magnet-Guided Bionic System with LIFU Responsiveness and Natural Thrombus Tropism for Enhanced Thrombus-Targeting Ability |
title_full | Magnet-Guided Bionic System with LIFU Responsiveness and Natural Thrombus Tropism for Enhanced Thrombus-Targeting Ability |
title_fullStr | Magnet-Guided Bionic System with LIFU Responsiveness and Natural Thrombus Tropism for Enhanced Thrombus-Targeting Ability |
title_full_unstemmed | Magnet-Guided Bionic System with LIFU Responsiveness and Natural Thrombus Tropism for Enhanced Thrombus-Targeting Ability |
title_short | Magnet-Guided Bionic System with LIFU Responsiveness and Natural Thrombus Tropism for Enhanced Thrombus-Targeting Ability |
title_sort | magnet-guided bionic system with lifu responsiveness and natural thrombus tropism for enhanced thrombus-targeting ability |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9087377/ https://www.ncbi.nlm.nih.gov/pubmed/35558339 http://dx.doi.org/10.2147/IJN.S357050 |
work_keys_str_mv | AT fangni magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT liujia magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT houjingxin magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT zhongyixin magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT luoying magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT huliu magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT zhangwenli magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT wangjunrui magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT xujie magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT zhoujun magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT zhangyu magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT ranhaitao magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability AT guodajing magnetguidedbionicsystemwithlifuresponsivenessandnaturalthrombustropismforenhancedthrombustargetingability |