Cargando…

A Multiple Emergency Ventilator as Backup Solution in Pandemic: A Specifically Designed and Dimensioned Device

Goal: To provide a Multiple Emergency Ventilator (MEV) as backup in case of shortage of ICU ventilators and for use in camp hospitals. Methods: MEV provides the same oxygen mixture and peak inspiratory pressure (PIP) to 10 patients. These specifications were fixed: i) gas supply and plugs to double-...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9088806/
https://www.ncbi.nlm.nih.gov/pubmed/35582706
http://dx.doi.org/10.1109/OJEMB.2022.3152673
_version_ 1784704388135124992
collection PubMed
description Goal: To provide a Multiple Emergency Ventilator (MEV) as backup in case of shortage of ICU ventilators and for use in camp hospitals. Methods: MEV provides the same oxygen mixture and peak inspiratory pressure (PIP) to 10 patients. These specifications were fixed: i) gas supply and plugs to double-limb intubation sets compatible to existing systems; ii) fluid-dynamics with no pressure drop and almost complete patients’ uncoupling; iii) individual monitoring of inspiratory and expiratory pressures and flows and control of their timing; iv) easy stocking, transport, installation with self-supporting pipes. Results: A Bell-Jar System (BJS) design permitted to safely fix PIP based on Archimedes’ law. The main distribution line was based on 2” stainless steel pipes assuring the required mechanical properties and over-dimensioned for fluidics. The Windkessel of the BJS and pipeline dead-volumes is 75.65 L and in the worst case of the instantaneous demand of 5 L by 10 patients (0.5 L each) shows an adiabatic PIP drop limited to –6.18%, confirming the needed uncoupling. Consequently, patients’ asynchrony is permitted as needed by pressure-controlled volume-guaranteed and assisted-ventilation. Conclusions: Although MEV is proposed as a backup system, its features may cover the whole set of ventilation modes required by ICU ventilation.
format Online
Article
Text
id pubmed-9088806
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-90888062022-05-13 A Multiple Emergency Ventilator as Backup Solution in Pandemic: A Specifically Designed and Dimensioned Device IEEE Open J Eng Med Biol Article Goal: To provide a Multiple Emergency Ventilator (MEV) as backup in case of shortage of ICU ventilators and for use in camp hospitals. Methods: MEV provides the same oxygen mixture and peak inspiratory pressure (PIP) to 10 patients. These specifications were fixed: i) gas supply and plugs to double-limb intubation sets compatible to existing systems; ii) fluid-dynamics with no pressure drop and almost complete patients’ uncoupling; iii) individual monitoring of inspiratory and expiratory pressures and flows and control of their timing; iv) easy stocking, transport, installation with self-supporting pipes. Results: A Bell-Jar System (BJS) design permitted to safely fix PIP based on Archimedes’ law. The main distribution line was based on 2” stainless steel pipes assuring the required mechanical properties and over-dimensioned for fluidics. The Windkessel of the BJS and pipeline dead-volumes is 75.65 L and in the worst case of the instantaneous demand of 5 L by 10 patients (0.5 L each) shows an adiabatic PIP drop limited to –6.18%, confirming the needed uncoupling. Consequently, patients’ asynchrony is permitted as needed by pressure-controlled volume-guaranteed and assisted-ventilation. Conclusions: Although MEV is proposed as a backup system, its features may cover the whole set of ventilation modes required by ICU ventilation. IEEE 2022-02-18 /pmc/articles/PMC9088806/ /pubmed/35582706 http://dx.doi.org/10.1109/OJEMB.2022.3152673 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
A Multiple Emergency Ventilator as Backup Solution in Pandemic: A Specifically Designed and Dimensioned Device
title A Multiple Emergency Ventilator as Backup Solution in Pandemic: A Specifically Designed and Dimensioned Device
title_full A Multiple Emergency Ventilator as Backup Solution in Pandemic: A Specifically Designed and Dimensioned Device
title_fullStr A Multiple Emergency Ventilator as Backup Solution in Pandemic: A Specifically Designed and Dimensioned Device
title_full_unstemmed A Multiple Emergency Ventilator as Backup Solution in Pandemic: A Specifically Designed and Dimensioned Device
title_short A Multiple Emergency Ventilator as Backup Solution in Pandemic: A Specifically Designed and Dimensioned Device
title_sort multiple emergency ventilator as backup solution in pandemic: a specifically designed and dimensioned device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9088806/
https://www.ncbi.nlm.nih.gov/pubmed/35582706
http://dx.doi.org/10.1109/OJEMB.2022.3152673
work_keys_str_mv AT amultipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT amultipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT amultipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT amultipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT amultipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT amultipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT amultipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT multipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT multipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT multipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT multipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT multipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT multipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice
AT multipleemergencyventilatorasbackupsolutioninpandemicaspecificallydesignedanddimensioneddevice