Cargando…

Sensitive and accurate detection of ALP activity using a fluorescence on–off–on switch and mass barcode signal amplification

Alkaline phosphatase (ALP) is an important biomarker for many diseases. Therefore, the sensitive and accurate detection of ALP activity is essential for fundamental biochemical processes and clinic diagnosis. Herein, we design a fluorescent on–off–on switch for sensitive and visual detection of ALP...

Descripción completa

Detalles Bibliográficos
Autores principales: Shu, Chang, Li, Duo, Li, Tengfei, Ji, Shunli, Ding, Li
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9088893/
https://www.ncbi.nlm.nih.gov/pubmed/35558943
http://dx.doi.org/10.1039/c8ra06973e
_version_ 1784704406520856576
author Shu, Chang
Li, Duo
Li, Tengfei
Ji, Shunli
Ding, Li
author_facet Shu, Chang
Li, Duo
Li, Tengfei
Ji, Shunli
Ding, Li
author_sort Shu, Chang
collection PubMed
description Alkaline phosphatase (ALP) is an important biomarker for many diseases. Therefore, the sensitive and accurate detection of ALP activity is essential for fundamental biochemical processes and clinic diagnosis. Herein, we design a fluorescent on–off–on switch for sensitive and visual detection of ALP activity. Meanwhile, mass barcode-modified quantum dots (QDs) amplified the LC-MS/MS detection signal in complex biological samples. Firstly, the QDs were modified with phosphorylated Gly-Gly-Phe-Phe-Tyr (OPO(3)H(2)) peptide (GGFFYp) and the mass barcode. The fluorescence of QDs-SS-Yp was quenched by fluorescence resonance energy transfer (FRET) between QDs-SS-Yp and dansyl chloride (DNS). ALP can hydrolyze the phosphorylated peptide to form peptide self-assemblies on the QDs-SS-Yp surfaces. The effective separation distance between the QDs-SS-Yp donor and DNS acceptor becomes larger, restricting FRET between the QDs-SS-Yp and DNS. At this point, the obvious QDs-SS-Yp fluorescence signal can be restored. However, the absence of ALP results in no peptide self-assembly on the QDs-SS-Yp surface and no obvious QDs-SS-Yp fluorescence signal was detected. Therefore, the ALP activity can be analyzed according to the degree of fluorescence restoration by the fluorescence on–off–on switch. Finally, the small tag molecules obtained by cleaving the disulfide bond of the QDs-SS-Yp as a mass barcode were used to amplify the LC-MS/MS detection signal. The proposed approach shows a good linear relationship (from 0.01 to 2.4 U L(−1)) and has the significant advantage of a low detection limit of 0.001 U L(−1).
format Online
Article
Text
id pubmed-9088893
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90888932022-05-11 Sensitive and accurate detection of ALP activity using a fluorescence on–off–on switch and mass barcode signal amplification Shu, Chang Li, Duo Li, Tengfei Ji, Shunli Ding, Li RSC Adv Chemistry Alkaline phosphatase (ALP) is an important biomarker for many diseases. Therefore, the sensitive and accurate detection of ALP activity is essential for fundamental biochemical processes and clinic diagnosis. Herein, we design a fluorescent on–off–on switch for sensitive and visual detection of ALP activity. Meanwhile, mass barcode-modified quantum dots (QDs) amplified the LC-MS/MS detection signal in complex biological samples. Firstly, the QDs were modified with phosphorylated Gly-Gly-Phe-Phe-Tyr (OPO(3)H(2)) peptide (GGFFYp) and the mass barcode. The fluorescence of QDs-SS-Yp was quenched by fluorescence resonance energy transfer (FRET) between QDs-SS-Yp and dansyl chloride (DNS). ALP can hydrolyze the phosphorylated peptide to form peptide self-assemblies on the QDs-SS-Yp surfaces. The effective separation distance between the QDs-SS-Yp donor and DNS acceptor becomes larger, restricting FRET between the QDs-SS-Yp and DNS. At this point, the obvious QDs-SS-Yp fluorescence signal can be restored. However, the absence of ALP results in no peptide self-assembly on the QDs-SS-Yp surface and no obvious QDs-SS-Yp fluorescence signal was detected. Therefore, the ALP activity can be analyzed according to the degree of fluorescence restoration by the fluorescence on–off–on switch. Finally, the small tag molecules obtained by cleaving the disulfide bond of the QDs-SS-Yp as a mass barcode were used to amplify the LC-MS/MS detection signal. The proposed approach shows a good linear relationship (from 0.01 to 2.4 U L(−1)) and has the significant advantage of a low detection limit of 0.001 U L(−1). The Royal Society of Chemistry 2018-10-29 /pmc/articles/PMC9088893/ /pubmed/35558943 http://dx.doi.org/10.1039/c8ra06973e Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Shu, Chang
Li, Duo
Li, Tengfei
Ji, Shunli
Ding, Li
Sensitive and accurate detection of ALP activity using a fluorescence on–off–on switch and mass barcode signal amplification
title Sensitive and accurate detection of ALP activity using a fluorescence on–off–on switch and mass barcode signal amplification
title_full Sensitive and accurate detection of ALP activity using a fluorescence on–off–on switch and mass barcode signal amplification
title_fullStr Sensitive and accurate detection of ALP activity using a fluorescence on–off–on switch and mass barcode signal amplification
title_full_unstemmed Sensitive and accurate detection of ALP activity using a fluorescence on–off–on switch and mass barcode signal amplification
title_short Sensitive and accurate detection of ALP activity using a fluorescence on–off–on switch and mass barcode signal amplification
title_sort sensitive and accurate detection of alp activity using a fluorescence on–off–on switch and mass barcode signal amplification
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9088893/
https://www.ncbi.nlm.nih.gov/pubmed/35558943
http://dx.doi.org/10.1039/c8ra06973e
work_keys_str_mv AT shuchang sensitiveandaccuratedetectionofalpactivityusingafluorescenceonoffonswitchandmassbarcodesignalamplification
AT liduo sensitiveandaccuratedetectionofalpactivityusingafluorescenceonoffonswitchandmassbarcodesignalamplification
AT litengfei sensitiveandaccuratedetectionofalpactivityusingafluorescenceonoffonswitchandmassbarcodesignalamplification
AT jishunli sensitiveandaccuratedetectionofalpactivityusingafluorescenceonoffonswitchandmassbarcodesignalamplification
AT dingli sensitiveandaccuratedetectionofalpactivityusingafluorescenceonoffonswitchandmassbarcodesignalamplification