Cargando…
Evaluation of SARS-CoV-2 genome detection by real-time PCR assay using pooled specimens
Objective: To evaluate SARS-CoV-2 genome detection using pooled samples by RT-qPCR assay, compared to individual samples. Method: At first all samples were tested individually using two commercial methods targeting ORF1ab, NP and E genes. Then, four experimental groups of samples were pooled and eva...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Future Medicine Ltd
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9090217/ https://www.ncbi.nlm.nih.gov/pubmed/35586148 http://dx.doi.org/10.2217/fvl-2021-0014 |
_version_ | 1784704674305146880 |
---|---|
author | Tavakoli, Forough Yavarian, Jila Shafiei Jandaghi, Nazanin Zahra Sadeghi, Kaveh Ghavami, Nastaran Salimi, Vahid Mokhtari-Azad, Talat |
author_facet | Tavakoli, Forough Yavarian, Jila Shafiei Jandaghi, Nazanin Zahra Sadeghi, Kaveh Ghavami, Nastaran Salimi, Vahid Mokhtari-Azad, Talat |
author_sort | Tavakoli, Forough |
collection | PubMed |
description | Objective: To evaluate SARS-CoV-2 genome detection using pooled samples by RT-qPCR assay, compared to individual samples. Method: At first all samples were tested individually using two commercial methods targeting ORF1ab, NP and E genes. Then, four experimental groups of samples were pooled and evaluated using the same detection methods. Findings: Compared to the individual sample testing, the sample pooling conserved the sensitivity of the detection in all groups of pooled samples when the Ct value in single test was lower than 33. Conclusion: Specimen pooling may fail to detect positive samples with high Ct values. However, in scarcity of reagents or in population surveys, it could be considered as an alternative method in low prevalence settings. |
format | Online Article Text |
id | pubmed-9090217 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Future Medicine Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-90902172022-05-16 Evaluation of SARS-CoV-2 genome detection by real-time PCR assay using pooled specimens Tavakoli, Forough Yavarian, Jila Shafiei Jandaghi, Nazanin Zahra Sadeghi, Kaveh Ghavami, Nastaran Salimi, Vahid Mokhtari-Azad, Talat Future Virol Methodology Objective: To evaluate SARS-CoV-2 genome detection using pooled samples by RT-qPCR assay, compared to individual samples. Method: At first all samples were tested individually using two commercial methods targeting ORF1ab, NP and E genes. Then, four experimental groups of samples were pooled and evaluated using the same detection methods. Findings: Compared to the individual sample testing, the sample pooling conserved the sensitivity of the detection in all groups of pooled samples when the Ct value in single test was lower than 33. Conclusion: Specimen pooling may fail to detect positive samples with high Ct values. However, in scarcity of reagents or in population surveys, it could be considered as an alternative method in low prevalence settings. Future Medicine Ltd 2022-05-09 2022-04 /pmc/articles/PMC9090217/ /pubmed/35586148 http://dx.doi.org/10.2217/fvl-2021-0014 Text en © 2022 Future Medicine Ltd https://creativecommons.org/licenses/by/4.0/This work is licensed under the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) |
spellingShingle | Methodology Tavakoli, Forough Yavarian, Jila Shafiei Jandaghi, Nazanin Zahra Sadeghi, Kaveh Ghavami, Nastaran Salimi, Vahid Mokhtari-Azad, Talat Evaluation of SARS-CoV-2 genome detection by real-time PCR assay using pooled specimens |
title | Evaluation of SARS-CoV-2 genome detection by real-time PCR assay using pooled specimens |
title_full | Evaluation of SARS-CoV-2 genome detection by real-time PCR assay using pooled specimens |
title_fullStr | Evaluation of SARS-CoV-2 genome detection by real-time PCR assay using pooled specimens |
title_full_unstemmed | Evaluation of SARS-CoV-2 genome detection by real-time PCR assay using pooled specimens |
title_short | Evaluation of SARS-CoV-2 genome detection by real-time PCR assay using pooled specimens |
title_sort | evaluation of sars-cov-2 genome detection by real-time pcr assay using pooled specimens |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9090217/ https://www.ncbi.nlm.nih.gov/pubmed/35586148 http://dx.doi.org/10.2217/fvl-2021-0014 |
work_keys_str_mv | AT tavakoliforough evaluationofsarscov2genomedetectionbyrealtimepcrassayusingpooledspecimens AT yavarianjila evaluationofsarscov2genomedetectionbyrealtimepcrassayusingpooledspecimens AT shafieijandaghinazaninzahra evaluationofsarscov2genomedetectionbyrealtimepcrassayusingpooledspecimens AT sadeghikaveh evaluationofsarscov2genomedetectionbyrealtimepcrassayusingpooledspecimens AT ghavaminastaran evaluationofsarscov2genomedetectionbyrealtimepcrassayusingpooledspecimens AT salimivahid evaluationofsarscov2genomedetectionbyrealtimepcrassayusingpooledspecimens AT mokhtariazadtalat evaluationofsarscov2genomedetectionbyrealtimepcrassayusingpooledspecimens |