Cargando…
Fatigue Failure of Outer Metal Dome of Bipolar Monoblock Shell in Hemiarthroplasty Hip: Case Report and Review of Literature
INTRODUCTION: We report a rare case of transmural wear-through of the polyethylene inner liner leading to fatigue failure of polished outer metallic dome of bipolar monoblock shell in cemented hemiarthroplasty 5-years after the index surgery. CASE PRESENTATION: A 62-year-old active man reported with...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9091384/ https://www.ncbi.nlm.nih.gov/pubmed/35611295 http://dx.doi.org/10.13107/jocr.2022.v12.i01.2618 |
_version_ | 1784704909668515840 |
---|---|
author | Shah, Vikram Indrajit Pachore, Javahir A Upadhyay, Sachin Shah, Kalpesh |
author_facet | Shah, Vikram Indrajit Pachore, Javahir A Upadhyay, Sachin Shah, Kalpesh |
author_sort | Shah, Vikram Indrajit |
collection | PubMed |
description | INTRODUCTION: We report a rare case of transmural wear-through of the polyethylene inner liner leading to fatigue failure of polished outer metallic dome of bipolar monoblock shell in cemented hemiarthroplasty 5-years after the index surgery. CASE PRESENTATION: A 62-year-old active man reported with 6 months of worsening right hip pain. He had undergone cemented bipolar hemiarthroplasty for sub-capital fracture of the right femur 5 years back. Radiographs demonstrate significant full-thickness wear-through of the Cobalt-Chromium head through the polyethylene inner liner and outer metal dome into the acetabulum. Biomechanics study revealed inadequate thickness of outer metallic dome of monoblock shell. Revision Total hip arthroplasty was performed. At the 5-year follow-up, radiographs show stable components and no clinical abnormality. CONCLUSION: Albeit rare, this failure mode aimed to raised awareness, routine follow-up, and quality assurance. |
format | Online Article Text |
id | pubmed-9091384 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-90913842022-05-23 Fatigue Failure of Outer Metal Dome of Bipolar Monoblock Shell in Hemiarthroplasty Hip: Case Report and Review of Literature Shah, Vikram Indrajit Pachore, Javahir A Upadhyay, Sachin Shah, Kalpesh J Orthop Case Rep Case Report INTRODUCTION: We report a rare case of transmural wear-through of the polyethylene inner liner leading to fatigue failure of polished outer metallic dome of bipolar monoblock shell in cemented hemiarthroplasty 5-years after the index surgery. CASE PRESENTATION: A 62-year-old active man reported with 6 months of worsening right hip pain. He had undergone cemented bipolar hemiarthroplasty for sub-capital fracture of the right femur 5 years back. Radiographs demonstrate significant full-thickness wear-through of the Cobalt-Chromium head through the polyethylene inner liner and outer metal dome into the acetabulum. Biomechanics study revealed inadequate thickness of outer metallic dome of monoblock shell. Revision Total hip arthroplasty was performed. At the 5-year follow-up, radiographs show stable components and no clinical abnormality. CONCLUSION: Albeit rare, this failure mode aimed to raised awareness, routine follow-up, and quality assurance. Indian Orthopaedic Research Group 2022-01 2022-01 /pmc/articles/PMC9091384/ /pubmed/35611295 http://dx.doi.org/10.13107/jocr.2022.v12.i01.2618 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Shah, Vikram Indrajit Pachore, Javahir A Upadhyay, Sachin Shah, Kalpesh Fatigue Failure of Outer Metal Dome of Bipolar Monoblock Shell in Hemiarthroplasty Hip: Case Report and Review of Literature |
title | Fatigue Failure of Outer Metal Dome of Bipolar Monoblock Shell in Hemiarthroplasty Hip: Case Report and Review of Literature |
title_full | Fatigue Failure of Outer Metal Dome of Bipolar Monoblock Shell in Hemiarthroplasty Hip: Case Report and Review of Literature |
title_fullStr | Fatigue Failure of Outer Metal Dome of Bipolar Monoblock Shell in Hemiarthroplasty Hip: Case Report and Review of Literature |
title_full_unstemmed | Fatigue Failure of Outer Metal Dome of Bipolar Monoblock Shell in Hemiarthroplasty Hip: Case Report and Review of Literature |
title_short | Fatigue Failure of Outer Metal Dome of Bipolar Monoblock Shell in Hemiarthroplasty Hip: Case Report and Review of Literature |
title_sort | fatigue failure of outer metal dome of bipolar monoblock shell in hemiarthroplasty hip: case report and review of literature |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9091384/ https://www.ncbi.nlm.nih.gov/pubmed/35611295 http://dx.doi.org/10.13107/jocr.2022.v12.i01.2618 |
work_keys_str_mv | AT shahvikramindrajit fatiguefailureofoutermetaldomeofbipolarmonoblockshellinhemiarthroplastyhipcasereportandreviewofliterature AT pachorejavahira fatiguefailureofoutermetaldomeofbipolarmonoblockshellinhemiarthroplastyhipcasereportandreviewofliterature AT upadhyaysachin fatiguefailureofoutermetaldomeofbipolarmonoblockshellinhemiarthroplastyhipcasereportandreviewofliterature AT shahkalpesh fatiguefailureofoutermetaldomeofbipolarmonoblockshellinhemiarthroplastyhipcasereportandreviewofliterature |