Cargando…

Disk solid-phase extraction of multi-class pharmaceutical residues in tap water and hospital wastewater, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses

In this work, a new clean-up and pre-concentration method based on disk solid-phase extraction (SPE) was developed to determine multi-class pharmaceutical residues covering a wide range of polarities (log K(ow) values from −0.5 to 5.1) in water systems, prior to ultra-performance liquid chromatograp...

Descripción completa

Detalles Bibliográficos
Autores principales: Kafeenah, Husam I. S., Osman, Rozita, Bakar, N. K. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9091434/
https://www.ncbi.nlm.nih.gov/pubmed/35558236
http://dx.doi.org/10.1039/c8ra06885b
_version_ 1784704921852968960
author Kafeenah, Husam I. S.
Osman, Rozita
Bakar, N. K. A.
author_facet Kafeenah, Husam I. S.
Osman, Rozita
Bakar, N. K. A.
author_sort Kafeenah, Husam I. S.
collection PubMed
description In this work, a new clean-up and pre-concentration method based on disk solid-phase extraction (SPE) was developed to determine multi-class pharmaceutical residues covering a wide range of polarities (log K(ow) values from −0.5 to 5.1) in water systems, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses. Electrospray ionisation in positive and negative modes was used for the simultaneous determination of both acidic and basic pharmaceuticals. The performances of disk SPE and cartridge SPE were compared. The targeted pharmaceutical compounds list included bronchodilators, antidiabetic drugs, antihypertensive drugs, a lipid-lowering agent, analgesics, and anti-inflammatory drugs. Based on our results, the disk SPE demonstrated a higher sensitivity and recovery value and less analysis time as compared to the cartridge SPE method. The limits of detection (LOD) for the new method ranged from 0.02–3.2 ng L(−1), 0.02–3.1 ng L(−1) and 0.02–4.7 ng L(−1) for tap, effluent and influent wastewater, respectively. The method's absolute recovery values ranged from 70% to 122% for tap water, 62% to 121% for effluent wastewater and 62% to 121% for influent wastewater, except for metformin in which the absolute recovery value was approximately 48% for all samples. Intra-day precision for tap water, effluent and influent wastewater ranged from 3–12%, 4–9% and 2–8%, respectively. The method developed was applied for the determination of targeted pharmaceuticals in tap, effluent, and influent wastewater from one hospital treatment plant in Malaysia. The results revealed that the highest concentrations of certain pharmaceuticals were up to 49 424 ng L(−1) (acetaminophen) and 1763 ng L(−1) (caffeine) in the influent and effluent wastewater, respectively. The results also showed a variation in the treatment efficiencies for the hospital treatment plant from one compound to another. Nevertheless, the removal efficiencies ranged from 0–99%.
format Online
Article
Text
id pubmed-9091434
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90914342022-05-11 Disk solid-phase extraction of multi-class pharmaceutical residues in tap water and hospital wastewater, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses Kafeenah, Husam I. S. Osman, Rozita Bakar, N. K. A. RSC Adv Chemistry In this work, a new clean-up and pre-concentration method based on disk solid-phase extraction (SPE) was developed to determine multi-class pharmaceutical residues covering a wide range of polarities (log K(ow) values from −0.5 to 5.1) in water systems, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses. Electrospray ionisation in positive and negative modes was used for the simultaneous determination of both acidic and basic pharmaceuticals. The performances of disk SPE and cartridge SPE were compared. The targeted pharmaceutical compounds list included bronchodilators, antidiabetic drugs, antihypertensive drugs, a lipid-lowering agent, analgesics, and anti-inflammatory drugs. Based on our results, the disk SPE demonstrated a higher sensitivity and recovery value and less analysis time as compared to the cartridge SPE method. The limits of detection (LOD) for the new method ranged from 0.02–3.2 ng L(−1), 0.02–3.1 ng L(−1) and 0.02–4.7 ng L(−1) for tap, effluent and influent wastewater, respectively. The method's absolute recovery values ranged from 70% to 122% for tap water, 62% to 121% for effluent wastewater and 62% to 121% for influent wastewater, except for metformin in which the absolute recovery value was approximately 48% for all samples. Intra-day precision for tap water, effluent and influent wastewater ranged from 3–12%, 4–9% and 2–8%, respectively. The method developed was applied for the determination of targeted pharmaceuticals in tap, effluent, and influent wastewater from one hospital treatment plant in Malaysia. The results revealed that the highest concentrations of certain pharmaceuticals were up to 49 424 ng L(−1) (acetaminophen) and 1763 ng L(−1) (caffeine) in the influent and effluent wastewater, respectively. The results also showed a variation in the treatment efficiencies for the hospital treatment plant from one compound to another. Nevertheless, the removal efficiencies ranged from 0–99%. The Royal Society of Chemistry 2018-12-03 /pmc/articles/PMC9091434/ /pubmed/35558236 http://dx.doi.org/10.1039/c8ra06885b Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Kafeenah, Husam I. S.
Osman, Rozita
Bakar, N. K. A.
Disk solid-phase extraction of multi-class pharmaceutical residues in tap water and hospital wastewater, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses
title Disk solid-phase extraction of multi-class pharmaceutical residues in tap water and hospital wastewater, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses
title_full Disk solid-phase extraction of multi-class pharmaceutical residues in tap water and hospital wastewater, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses
title_fullStr Disk solid-phase extraction of multi-class pharmaceutical residues in tap water and hospital wastewater, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses
title_full_unstemmed Disk solid-phase extraction of multi-class pharmaceutical residues in tap water and hospital wastewater, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses
title_short Disk solid-phase extraction of multi-class pharmaceutical residues in tap water and hospital wastewater, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (UPLC-MS/MS) analyses
title_sort disk solid-phase extraction of multi-class pharmaceutical residues in tap water and hospital wastewater, prior to ultra-performance liquid chromatographic-tandem mass spectrometry (uplc-ms/ms) analyses
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9091434/
https://www.ncbi.nlm.nih.gov/pubmed/35558236
http://dx.doi.org/10.1039/c8ra06885b
work_keys_str_mv AT kafeenahhusamis disksolidphaseextractionofmulticlasspharmaceuticalresiduesintapwaterandhospitalwastewaterpriortoultraperformanceliquidchromatographictandemmassspectrometryuplcmsmsanalyses
AT osmanrozita disksolidphaseextractionofmulticlasspharmaceuticalresiduesintapwaterandhospitalwastewaterpriortoultraperformanceliquidchromatographictandemmassspectrometryuplcmsmsanalyses
AT bakarnka disksolidphaseextractionofmulticlasspharmaceuticalresiduesintapwaterandhospitalwastewaterpriortoultraperformanceliquidchromatographictandemmassspectrometryuplcmsmsanalyses