Cargando…

Investigation on the thermo-electric-electrochemical characteristics of retired LFP batteries for echelon applications

Electric vehicles (EVs) have been developed to alleviate environmental pollution and climate change, but they leave behind a large amount of retired lithium-ion batteries (LIBs). Since the replacement of LIBs from EVs will lead to considerable waste generation, improving the echelon utilization of r...

Descripción completa

Detalles Bibliográficos
Autores principales: Lv, Youfu, Luo, Weiming, Mo, Ya, Zhang, Guoqing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9092358/
https://www.ncbi.nlm.nih.gov/pubmed/35558830
http://dx.doi.org/10.1039/d2ra02278h
_version_ 1784705123894689792
author Lv, Youfu
Luo, Weiming
Mo, Ya
Zhang, Guoqing
author_facet Lv, Youfu
Luo, Weiming
Mo, Ya
Zhang, Guoqing
author_sort Lv, Youfu
collection PubMed
description Electric vehicles (EVs) have been developed to alleviate environmental pollution and climate change, but they leave behind a large amount of retired lithium-ion batteries (LIBs). Since the replacement of LIBs from EVs will lead to considerable waste generation, improving the echelon utilization of retired LIBs is becoming increasingly critical. In this paper, we studied the thermo-electric-electrochemical performance of retired LiFePO(4) (LFP) batteries using traditional methods, and found that the remaining capacity of retired LFP batteries has a strong correlation with their internal resistance. This result helped us to propose a rapid and elementary classification method for the calibration of the remaining capacity, and to then formulate a test protocol seeking to balance the time spent and the test cost. Besides, the cut-off voltage and charge–discharge current density have a significant impact on the calibration of the remaining capacity, especially for retired LFP batteries with low residual capacity. In the cycle life test and temperature reliability evaluation process, the results demonstrate that the retired LFP batteries have a good service life when under a lower current of charge/discharge, and the capacity reductions were 2.3%, 11.2% and 4.8% for retired LFP batteries with 80% state of health (SOH), 70% SOH and 60% SOH, respectively, after 500 cycles. Finally, considering the temperature reliability, voltage consistency and large current cycling performance of retired LFP batteries, there are still many challenges in their future echelon utilization.
format Online
Article
Text
id pubmed-9092358
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90923582022-05-11 Investigation on the thermo-electric-electrochemical characteristics of retired LFP batteries for echelon applications Lv, Youfu Luo, Weiming Mo, Ya Zhang, Guoqing RSC Adv Chemistry Electric vehicles (EVs) have been developed to alleviate environmental pollution and climate change, but they leave behind a large amount of retired lithium-ion batteries (LIBs). Since the replacement of LIBs from EVs will lead to considerable waste generation, improving the echelon utilization of retired LIBs is becoming increasingly critical. In this paper, we studied the thermo-electric-electrochemical performance of retired LiFePO(4) (LFP) batteries using traditional methods, and found that the remaining capacity of retired LFP batteries has a strong correlation with their internal resistance. This result helped us to propose a rapid and elementary classification method for the calibration of the remaining capacity, and to then formulate a test protocol seeking to balance the time spent and the test cost. Besides, the cut-off voltage and charge–discharge current density have a significant impact on the calibration of the remaining capacity, especially for retired LFP batteries with low residual capacity. In the cycle life test and temperature reliability evaluation process, the results demonstrate that the retired LFP batteries have a good service life when under a lower current of charge/discharge, and the capacity reductions were 2.3%, 11.2% and 4.8% for retired LFP batteries with 80% state of health (SOH), 70% SOH and 60% SOH, respectively, after 500 cycles. Finally, considering the temperature reliability, voltage consistency and large current cycling performance of retired LFP batteries, there are still many challenges in their future echelon utilization. The Royal Society of Chemistry 2022-05-11 /pmc/articles/PMC9092358/ /pubmed/35558830 http://dx.doi.org/10.1039/d2ra02278h Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Lv, Youfu
Luo, Weiming
Mo, Ya
Zhang, Guoqing
Investigation on the thermo-electric-electrochemical characteristics of retired LFP batteries for echelon applications
title Investigation on the thermo-electric-electrochemical characteristics of retired LFP batteries for echelon applications
title_full Investigation on the thermo-electric-electrochemical characteristics of retired LFP batteries for echelon applications
title_fullStr Investigation on the thermo-electric-electrochemical characteristics of retired LFP batteries for echelon applications
title_full_unstemmed Investigation on the thermo-electric-electrochemical characteristics of retired LFP batteries for echelon applications
title_short Investigation on the thermo-electric-electrochemical characteristics of retired LFP batteries for echelon applications
title_sort investigation on the thermo-electric-electrochemical characteristics of retired lfp batteries for echelon applications
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9092358/
https://www.ncbi.nlm.nih.gov/pubmed/35558830
http://dx.doi.org/10.1039/d2ra02278h
work_keys_str_mv AT lvyoufu investigationonthethermoelectricelectrochemicalcharacteristicsofretiredlfpbatteriesforechelonapplications
AT luoweiming investigationonthethermoelectricelectrochemicalcharacteristicsofretiredlfpbatteriesforechelonapplications
AT moya investigationonthethermoelectricelectrochemicalcharacteristicsofretiredlfpbatteriesforechelonapplications
AT zhangguoqing investigationonthethermoelectricelectrochemicalcharacteristicsofretiredlfpbatteriesforechelonapplications