The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery

OBJECTIVES: To retrospectively analyse the potential influencing factors of CT-guided hook wire localization failure prior to thoracoscopic resection surgery of ground glass nodules (GGNs), and determine the main risk elements for localization failure. METHODS: In all, 372 patients were included in...

Descripción completa

Detalles Bibliográficos
Autores principales: Ala, Musu, Liu, Junzhong, Kou, Jieli, Wang, Xinhua, Sun, Minfeng, Hao, Changcheng, Wu, Jianlin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9092699/
https://www.ncbi.nlm.nih.gov/pubmed/35546677
http://dx.doi.org/10.1186/s13019-022-01866-y
_version_ 1784705187325149184
author Ala, Musu
Liu, Junzhong
Kou, Jieli
Wang, Xinhua
Sun, Minfeng
Hao, Changcheng
Wu, Jianlin
author_facet Ala, Musu
Liu, Junzhong
Kou, Jieli
Wang, Xinhua
Sun, Minfeng
Hao, Changcheng
Wu, Jianlin
author_sort Ala, Musu
collection PubMed
description OBJECTIVES: To retrospectively analyse the potential influencing factors of CT-guided hook wire localization failure prior to thoracoscopic resection surgery of ground glass nodules (GGNs), and determine the main risk elements for localization failure. METHODS: In all, 372 patients were included in this study, with 21 patients showing localization failure. The related parameters of patients, GGNs, and localization were analysed through univariate and multiple logistic regression analysis to determine the risk factors of localization failure. RESULTS: Univariate logistic regression analysis indicated that trans-fissure (odds ratio [OR] 4.896, 95% confidence interval [CI] 1.489–13.939); trans-emphysema (OR 3.538, 95% CI 1.343–8.827); localization time (OR 0.956, 95% CI 0.898–1.019); multi-nodule localization (OR 2.597, 95% CI 1.050–6.361); and pneumothorax (OR 10.326, 95% CI 3.414–44.684) were risk factors for localization failure, and the p-values of these factors were < 0.05. However, according to the results of multivariate analysis, pneumothorax (OR 5.998, 95% CI 1.680–28.342) was an exclusive risk factor for the failure of preoperative localization of GGNs. CONCLUSION: CT-guided hook wire localization of GGNs prior to thoracoscopic surgery is often known to fail; however, the incidence is low. Pneumothorax is an independent risk factor for failure in the localization process.
format Online
Article
Text
id pubmed-9092699
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-90926992022-05-12 The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery Ala, Musu Liu, Junzhong Kou, Jieli Wang, Xinhua Sun, Minfeng Hao, Changcheng Wu, Jianlin J Cardiothorac Surg Research Article OBJECTIVES: To retrospectively analyse the potential influencing factors of CT-guided hook wire localization failure prior to thoracoscopic resection surgery of ground glass nodules (GGNs), and determine the main risk elements for localization failure. METHODS: In all, 372 patients were included in this study, with 21 patients showing localization failure. The related parameters of patients, GGNs, and localization were analysed through univariate and multiple logistic regression analysis to determine the risk factors of localization failure. RESULTS: Univariate logistic regression analysis indicated that trans-fissure (odds ratio [OR] 4.896, 95% confidence interval [CI] 1.489–13.939); trans-emphysema (OR 3.538, 95% CI 1.343–8.827); localization time (OR 0.956, 95% CI 0.898–1.019); multi-nodule localization (OR 2.597, 95% CI 1.050–6.361); and pneumothorax (OR 10.326, 95% CI 3.414–44.684) were risk factors for localization failure, and the p-values of these factors were < 0.05. However, according to the results of multivariate analysis, pneumothorax (OR 5.998, 95% CI 1.680–28.342) was an exclusive risk factor for the failure of preoperative localization of GGNs. CONCLUSION: CT-guided hook wire localization of GGNs prior to thoracoscopic surgery is often known to fail; however, the incidence is low. Pneumothorax is an independent risk factor for failure in the localization process. BioMed Central 2022-05-11 /pmc/articles/PMC9092699/ /pubmed/35546677 http://dx.doi.org/10.1186/s13019-022-01866-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Ala, Musu
Liu, Junzhong
Kou, Jieli
Wang, Xinhua
Sun, Minfeng
Hao, Changcheng
Wu, Jianlin
The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery
title The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery
title_full The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery
title_fullStr The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery
title_full_unstemmed The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery
title_short The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery
title_sort risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9092699/
https://www.ncbi.nlm.nih.gov/pubmed/35546677
http://dx.doi.org/10.1186/s13019-022-01866-y
work_keys_str_mv AT alamusu theriskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT liujunzhong theriskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT koujieli theriskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT wangxinhua theriskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT sunminfeng theriskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT haochangcheng theriskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT wujianlin theriskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT alamusu riskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT liujunzhong riskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT koujieli riskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT wangxinhua riskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT sunminfeng riskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT haochangcheng riskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery
AT wujianlin riskfactorsforthefailureofhookwirelocalizationofgroundglassnodulespriortothoracoscopicsurgery