A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis
PURPOSE: This study evaluated screw loosening and 3D crown displacement after cyclic loading of implant-supported incisor crowns cemented with original titanium bases or with three compatible, nonoriginal components. MATERIALS AND METHODS: A total of 32 dental implants were divided into four groups...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9095448/ https://www.ncbi.nlm.nih.gov/pubmed/35601348 http://dx.doi.org/10.4047/jap.2022.14.2.70 |
_version_ | 1784705753015123968 |
---|---|
author | Ožiūnas, Rimantas Sakalauskienė, Jurgina Jegelevičius, Darius Janužis, Gintaras |
author_facet | Ožiūnas, Rimantas Sakalauskienė, Jurgina Jegelevičius, Darius Janužis, Gintaras |
author_sort | Ožiūnas, Rimantas |
collection | PubMed |
description | PURPOSE: This study evaluated screw loosening and 3D crown displacement after cyclic loading of implant-supported incisor crowns cemented with original titanium bases or with three compatible, nonoriginal components. MATERIALS AND METHODS: A total of 32 dental implants were divided into four groups (n = 8 each): Group 1 used original titanium bases, while Groups 2-4 used compatible components. The reverse torque value (RTV) was evaluated prior to and after cyclic loading (1,200,000 cycles). Samples (prior to and after cyclic loading) were scanned with a microcomputed tomography (micro-CT). Preload and postload files were superimposed by 3D inspection software, and 3D crown displacement analysis was performed using root-mean-square (RMS) values. All datasets were analyzed using one-way ANOVA and Tukey’s post hoc analysis. RESULTS: Significant variations were observed in the postload RTV, depending on the titanium base brand (P < .001). The mean postload RTVs were significantly higher in Groups 1 and 2 than in the other study groups. While evaluating 3D crown displacement, the lowest mean RMS value was shown in the original Group 1, with the highest RMS value occurring in Group 4. CONCLUSION: Within the limitations of this in vitro study and under the implemented conditions, it was concluded that the manufacturer brand of the titanium base significantly influenced screw loosening following the fatigue test and influenced 3D crown displacement after cyclic loading. |
format | Online Article Text |
id | pubmed-9095448 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-90954482022-05-19 A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis Ožiūnas, Rimantas Sakalauskienė, Jurgina Jegelevičius, Darius Janužis, Gintaras J Adv Prosthodont Original Article PURPOSE: This study evaluated screw loosening and 3D crown displacement after cyclic loading of implant-supported incisor crowns cemented with original titanium bases or with three compatible, nonoriginal components. MATERIALS AND METHODS: A total of 32 dental implants were divided into four groups (n = 8 each): Group 1 used original titanium bases, while Groups 2-4 used compatible components. The reverse torque value (RTV) was evaluated prior to and after cyclic loading (1,200,000 cycles). Samples (prior to and after cyclic loading) were scanned with a microcomputed tomography (micro-CT). Preload and postload files were superimposed by 3D inspection software, and 3D crown displacement analysis was performed using root-mean-square (RMS) values. All datasets were analyzed using one-way ANOVA and Tukey’s post hoc analysis. RESULTS: Significant variations were observed in the postload RTV, depending on the titanium base brand (P < .001). The mean postload RTVs were significantly higher in Groups 1 and 2 than in the other study groups. While evaluating 3D crown displacement, the lowest mean RMS value was shown in the original Group 1, with the highest RMS value occurring in Group 4. CONCLUSION: Within the limitations of this in vitro study and under the implemented conditions, it was concluded that the manufacturer brand of the titanium base significantly influenced screw loosening following the fatigue test and influenced 3D crown displacement after cyclic loading. The Korean Academy of Prosthodontics 2022-04 2022-04-27 /pmc/articles/PMC9095448/ /pubmed/35601348 http://dx.doi.org/10.4047/jap.2022.14.2.70 Text en © 2022 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ožiūnas, Rimantas Sakalauskienė, Jurgina Jegelevičius, Darius Janužis, Gintaras A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis |
title | A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis |
title_full | A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis |
title_fullStr | A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis |
title_full_unstemmed | A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis |
title_short | A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis |
title_sort | comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3d-crown displacement following cyclic loading analysis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9095448/ https://www.ncbi.nlm.nih.gov/pubmed/35601348 http://dx.doi.org/10.4047/jap.2022.14.2.70 |
work_keys_str_mv | AT oziunasrimantas acomparativebiomechanicalstudyoforiginalandcompatibletitaniumbasesevaluationofscrewlooseningand3dcrowndisplacementfollowingcyclicloadinganalysis AT sakalauskienejurgina acomparativebiomechanicalstudyoforiginalandcompatibletitaniumbasesevaluationofscrewlooseningand3dcrowndisplacementfollowingcyclicloadinganalysis AT jegeleviciusdarius acomparativebiomechanicalstudyoforiginalandcompatibletitaniumbasesevaluationofscrewlooseningand3dcrowndisplacementfollowingcyclicloadinganalysis AT januzisgintaras acomparativebiomechanicalstudyoforiginalandcompatibletitaniumbasesevaluationofscrewlooseningand3dcrowndisplacementfollowingcyclicloadinganalysis AT oziunasrimantas comparativebiomechanicalstudyoforiginalandcompatibletitaniumbasesevaluationofscrewlooseningand3dcrowndisplacementfollowingcyclicloadinganalysis AT sakalauskienejurgina comparativebiomechanicalstudyoforiginalandcompatibletitaniumbasesevaluationofscrewlooseningand3dcrowndisplacementfollowingcyclicloadinganalysis AT jegeleviciusdarius comparativebiomechanicalstudyoforiginalandcompatibletitaniumbasesevaluationofscrewlooseningand3dcrowndisplacementfollowingcyclicloadinganalysis AT januzisgintaras comparativebiomechanicalstudyoforiginalandcompatibletitaniumbasesevaluationofscrewlooseningand3dcrowndisplacementfollowingcyclicloadinganalysis |